ADEMCO FlexGuard 5852 Скачать руководство пользователя страница 2

 

– 2 – 

+

J1

XL1

J2

+

-

NC

TAMP.
TAMP.

U1

TEST
MODE
PADS

SW3 (SENS1
AND SENS2
SWITCHES)

COVER
TAMPER
SWITCH

ENROLL
SWITCH

ENR

OLL

SWITCH

5852-003-V0

LED ENABLE
SWITCH

 

Figure 3.  5852 with Cover Assembly Removed

 

 

1. 

With the sensor in the approximate mounting location, carefully 
open cover door.  Avoid opening door too far or too fast. 

2.  Enable LEDs for test purposes by sliding the LED Enable 

switch in the direction of the printed arrow (an orange tab will 
protrude from the side of the sensor). See Figure 2, or use 
procedure for entering the Remote LED Enable/Disable Mode 
provided in this document. 

3.  Use a small screwdriver (or similar tool) to move the SENS1 

and SENS2 switches to the desired positions (see table below). 

 

ON   OFF

SENS1

SENS2

 

 

SENSITIVITY 

 

SENS1 

 

SENS2 

APPROX. 
RANGE* 

Max 

OFF 

OFF 

25 ft (7.6 m) 

Med 

ON 

OFF 

15 ft (4.6 m) 

Low 

OFF 

ON 

 10 ft (3 m) 

Lowest 

ON 

ON 

5 ft (1.5 m) 

*  Verify range with the Intellisense Model FG-701 or Ademco 
  GBS7 Glassbreak Simulator. 

 

4.  Turn on any heating/air conditioning systems and other 

equipment in the sensor's vicinity.  

5.  Observe the green Event LED for about one minute.  If the 

green LED flashes, the sensor should be relocated. 

6. 

After adjustment, disable LEDs and close cover door. 

 

REMOTE LED ENABLE/DISABLE MODE 

The sensor’s Remote LED Enable/Disable mode allows you to 
enable or disable the sensor’s LEDs with the FG-701 Glassbreak 
Simulator.  To enable or disable LEDs with the FG-701, 
proceed as follows: 
1. 

Set LED switch S4, position 4 to OFF. 

2. 

Set the FG-701 switches to the ACTIVATE and MANUAL 
positions. 

3.  Stand within 15 feet (4.6 m) of the sensor, point front of 

FG-701 at sensor, and press red START button.  The 
simulator generates an audio activation signal, and the 
sensor’s green LED flashes once per second. 

4.  Repeat step 3, and the sensor’s green LED will stop 

flashing. 

5.  Within 2 seconds, repeat step 3 to send another activation 

code.  If disabling LEDs, the sensor’s green LED will flash 

once.  If enabling LEDs, the green LED will flash two or 
three times. 

6.  Clap your hands to test LEDs.  If LEDs are enabled, the 

green LED will flicker.  If LEDs are disabled, the green 
LED will remain off. 

 

"ENROLLING" THE 5852 SERIAL NUMBER 

The 5852's serial number must be "enrolled" by the control 
panel prior to use in the system.  The control panel's installation 
instructions provide detailed programming instructions for 
"enrolling" transmitter serial numbers.  Before programming, 
proceed as follows: 

1. 

Install battery (if not installed).  Observe polarity! 

2. 

Remove cover assembly. 

3. 

When programming the transmitter, note the following: 

 

•  Input Type = 3 (Supervised RF) 

 

•  Loop Number = 1 
When prompted, transmit from the sensor (momentarily 
press the enroll switch located on the exposed transmitter 
PC board, press the tamper switch, etc.). You can also 
manually enter the sensor’s serial number. 

4.  Test the sensor after "enrolling" the serial number in the 

system.  Refer to the Testing the 5852 section. 

 

MOUNTING 

1.  Determine the optimum mounting location, noting the 

following (see Figure 4): 

  Mount on ceiling or wall, at least 7 feet from floor. 

  Ensure that the sensor has a direct, unobstructed line-of-

sight to the protected glass. 

  Mount no more than 25 feet from the farthest protected 

glass. 

  Make sure there are no intervening partitions, curtains, 

etc. that could block the transfer of shock or sound 
waves. 

 

NOTE:

  If window dressing is present, it will absorb 

sound energy from breaking glass.  In such cases, the 
sensor should be mounted between the protected glass 
and the window dressing. 

 Avoid locating the sensor near sources of ambient 

vibration or sound, such as air conditioners, fans, 
blowers, air ducts, or loudspeakers. 

  Avoid locations where furniture can be moved so that it 

blocks the sensor's line-of sight to the glass. 

  Avoid locations where a door can be opened or closed 

such that it blocks the sensor's line of sight to the glass. 

  Avoid locations near doors or windows that may be 

slammed. 

2.  Before permanently mounting the 5852, conduct tests to 

verify adequate signal strength (refer to control panel 
instructions), and, if necessary, relocate the 5852 (pressing 
the sensor's test switch will send a transmission).  It is also 
recommended that, before mounting permanently, the 
sensor should be tested to ensure it is within reliable audio 
and flex range from the protected glass.  Refer to the 
Testing the 5852 section for the procedure. 

3. 

If not already removed, remove the sensor's cover assembly 
by removing the screw located near the LED Enable 
switch.  Carefully pull cover assembly away from case. 

4.  Mark the mounting hole locations on the ceiling or wall 

using the case as a template. 

 

SW3 

www.PDF-Zoo.com

firealarmresources.com

Содержание FlexGuard 5852

Страница 1: ... sensitivity Refer to the Adjusting Sensitivity section 3 Enroll the sensor s serial number using the control panel s programming procedure Refer to the Enrolling the 5852 Serial Number section 4 Mount the sensor Refer to the Mounting section 5 Test the sensor Refer to the Testing the 5852 section NOTE The cover tamper switch is activated when the door is open transmitter will send tamper signal t...

Страница 2: ...prior to use in the system The control panel s installation instructions provide detailed programming instructions for enrolling transmitter serial numbers Before programming proceed as follows 1 Install battery if not installed Observe polarity 2 Remove cover assembly 3 When programming the transmitter note the following Input Type 3 Supervised RF Loop Number 1 When prompted transmit from the sen...

Страница 3: ...ed 2 Set glassbreak simulator switches to the TEST and FLEX positions 3 Press the red START button on the simulator The simulator will click on and starts an 8 second armed period 4 Position the simulator near the farthest point of the protected glass and point it directly at the 5852 sensor If window coverings are present close them fully and hold the simulator between the coverings and the prote...

Страница 4: ...1 4 in Coated 2 3 mm 1 8 in 6 4 mm 1 4 in Sealed Insulating 1 3 mm 1 8 in 6 mm 1 4 in Maximum overall 7 16 in Minimum size for all types is 28 cm 11 in square glass must be framed in the wall or mounted in a barrier at least 0 9 m 36 in wide 1 Protected only if both plates of the unit are broken 2 Coated glass with security films including films for solar protection up to 12 mil thick may be used ...

Отзывы: