GENERAL INFORMATION 

The 5852 Wireless Glassbreak Sensor with Transmitter is used in 
systems that support 5800 wireless devices.  The self-contained 
sensor includes a transmitter that can send alarms, tamper signals, 
and low battery messages to the control panel.  Each 5852 has a 
unique identification code (serial number ID) permanently assigned 
during manufacture.  The ID must be "enrolled" by the control panel 
prior to use in a system.  The sensor is designed for continuous 
operation using a single 9V lithium battery. 

 

LED INDICATORS 

The 5852 is equipped with two built-in LED indicators, a green 
Event LED and a red Alarm LED.  When the LEDs are enabled, they 
light in a variety of patterns to convey the sensor’s operational status. 
The table below summarizes the LED messages. 

 

Condition 

Green LED 

Red LED 

Normal OFF 

OFF 

Normal, event detected 

Flicker 

OFF 

Normal, event detected 
and alarm in memory 

 
Flicker 

 
Flash 5 secs 

Normal, break detected 

OFF 

ON 5 secs 

Power-up self-test 

ON 1 sec 

ON 1 sec 

Trouble detected 

Flash ON/OFF 

Flash ON/OFF 

Low battery 

Flash ON/OFF 

Flash ON/OFF 

Test mode 

Flash once per sec 

OFF 

Test mode, event detected  Flicker 

OFF 

Test mode, alarm 

Flash once per sec 

ON 5 secs 

 

NOTE: 

  If the green LED is flashing and the red LED is ON 

continuously, there is a self-test failure and a low battery condition. 

 

TYPES OF GLASS PROTECTED BY THE 5852 

• Tempered Glass 

• Laminated Type Glass 

• Ordinary Plate Glass 

• Wired Plate Glass 

Refer to the nominal thickness chart later in this document.  The 
5852 is not recommended for protection of glass areas that are less 
than 10-7/8 inches by 10-7/8 inches. 

 

INSTALLATION PROCEDURE 

Refer to the sections indicated in the following steps for details of the 
procedures. 

1. 

Install the battery.  Refer to the Installing the Battery section. 

Adjust the sensor's sensitivity.  Refer to the Adjusting Sensitivity 
section. 

3.  "Enroll" the sensor's serial number using the control panel’s 

programming procedure.  Refer to the Enrolling the 5852 Serial 
Number 
section. 

4. 

Mount the sensor.  Refer to the Mounting section. 

5. 

Test the sensor.  Refer to the Testing the 5852 section. 

 

NOTE:  

The cover tamper switch is activated when the door is open; 

transmitter will send tamper signal to the control panel.  Refer to the 
Tamper Switch section of this document. 

 

 

EVENT LED (GREEN)

ALARM LED (RED)

5852-001-V0

 

 

Figure 1.  5852 Glassbreak Sensor with Transmitter 

 

LED ENABLE

EVENT

ALARM

ON  OFF

TEST MODE

EVENT
(GREEN) LED

SW3

SW4
TEST MODE
PADS

SERVICE DOOR
TAMPER SWITCH

LED ENABLE

SWITCH

REMOVE THIS

SCREW TO
SEPARATE

HOUSING

SERVICE
DOOR
(OPEN)

SENS2

SENS1

ALARM
(RED) LED

INSTALL

9-V

LITHIUM

BATTERY

HERE

5852-002-V0

 

Figure 2.  5852 with Door Open 

 

INSTALLING THE BATTERY 

WARNINGS: 

• 

Use only UltraLife Model U9VL–J 9-volt lithium 
battery.
  Use of another battery may present a risk of fire 
or explosion. 

• 

Battery may explode if mistreated.  Do not recharge, 
disassemble, or dispose of battery in fire. 

1. 

Open cover door. 

2.  Check battery polarity orientation before installing. Insert 

battery into battery holder with terminals toward ledge with 
embossed polarity markings. 

3. 

Press back end of battery down until it is securely seated in 
holder.  Close cover door. 

4. 

Wait at least 30 seconds to allow sensor to warm up; then 
test unit to ensure proper operation. 

To remove the battery, pry up back end of battery with 
screwdriver (or similar tool) until it can easily be removed. 

 

NOTE:

  If a low battery message is displayed at the keypad, but 

you suspect the battery is not actually low, remove the battery, 
wait at least 30 seconds, then re-install the battery and re-test the 
5852 sensor. 

 

ADJUSTING SENSITIVITY 

 

The 5852 has a maximum detection range of 25 feet (7.6 m) 
with a sensitivity selection from maximum to lowest in four 
settings. Sensitivity is selected with the SENS1 and SENS2 
switches (SW3 in Figure 3).   

INSTALLATION INSTRUCTIONS 

®

 

 

www.PDF-Zoo.com

firealarmresources.com

Содержание FlexGuard 5852

Страница 1: ... sensitivity Refer to the Adjusting Sensitivity section 3 Enroll the sensor s serial number using the control panel s programming procedure Refer to the Enrolling the 5852 Serial Number section 4 Mount the sensor Refer to the Mounting section 5 Test the sensor Refer to the Testing the 5852 section NOTE The cover tamper switch is activated when the door is open transmitter will send tamper signal t...

Страница 2: ...prior to use in the system The control panel s installation instructions provide detailed programming instructions for enrolling transmitter serial numbers Before programming proceed as follows 1 Install battery if not installed Observe polarity 2 Remove cover assembly 3 When programming the transmitter note the following Input Type 3 Supervised RF Loop Number 1 When prompted transmit from the sen...

Страница 3: ...ed 2 Set glassbreak simulator switches to the TEST and FLEX positions 3 Press the red START button on the simulator The simulator will click on and starts an 8 second armed period 4 Position the simulator near the farthest point of the protected glass and point it directly at the 5852 sensor If window coverings are present close them fully and hold the simulator between the coverings and the prote...

Страница 4: ...1 4 in Coated 2 3 mm 1 8 in 6 4 mm 1 4 in Sealed Insulating 1 3 mm 1 8 in 6 mm 1 4 in Maximum overall 7 16 in Minimum size for all types is 28 cm 11 in square glass must be framed in the wall or mounted in a barrier at least 0 9 m 36 in wide 1 Protected only if both plates of the unit are broken 2 Coated glass with security films including films for solar protection up to 12 mil thick may be used ...

Отзывы: