– 16 –
Question 9a
Pulse Z1 (Y/N)
Press Y if zone 1 is connected to a pulsed bell output. Question 9c will
appear. If N is pressed, the following appears.
Question 9b
Z1 Delay
(00-127)
Enter the reporting delay from 1-127 seconds for
zone 1. Enter 00 for no reporting delay.
Question 9c
Pulse Cnt? (Y/N)
(03 - 254)
If Pulsed Zone is answered Y, the next question will
be Pulse Cnt? Input the number of pulses required
to place the zone in alarm. Default is (03).
Question 10a
Pulse Z2 (Y/N)
Press Y if zone 2 is connected to a pulsed bell output. Question 10c will
appear. If N is pressed, the following appears.
Question 10b
Z2 Delay
(00-127)
Enter the reporting delay from 1-127 seconds for
zone 2. Enter 00 for no reporting delay.
Question 10c
Pulse Cnt? (Y/N)
(03 - 254)
If Pulsed Zone is answered Y, the next question will
be Pulse Cnt? Input the number of pulses required
to place the zone in alarm. Default is (03).
Question 11a
Pulse Z3 (Y/N)
Press Y if zone 3 is connected to a pulsed bell output. Question 11c will
appear. If N is pressed, the following appears.
Question 11b
Z3 Delay
(00-127)
Enter the reporting delay from 1-127 seconds for
zone 3. Enter 00 for no reporting delay.
Question 11c
Pulse Cnt? (Y/N)
(03 - 254)
If Pulsed Zone is answered Y, the next question will
be Pulse Cnt? Input the number of pulses required
to place the zone in alarm. Default is (03).
Question 12a
Pulse Z4 (Y/N)
Press Y if zone 4 is connected to a pulsed bell output. Question 12c will
appear. If N is pressed, the following appears.
Question 12b
Z4 Delay
(00-127)
Enter the reporting delay from 1-127 seconds for
zone 4. Enter 00 for no reporting delay.
Question 12c
Pulse Cnt? (Y/N)
(03 - 254)
If Pulsed Zone is answered Y, the next question will
be Pulse Cnt? Input the number of pulses required
to place the zone in alarm. Default is (03).