background image

 

- 2 -

 

- 3 -

 

6.  Attach the case back to the mounting plate by sliding the keyhole slots in the case 

back down onto the mounting plate's holding posts. The locking tab will click as the case 
back locks in place. To disengage the unit from an installed mounting plate, insert a 
small screwdriver into the mounting plate release hole, push down to retract the locking 
tab, and push upward on the unit to disengage from posts. 

7. 

Set the DIP switch (after the control panel has enrolled the transmitter's input IDs) for 
the desired primary loop characteristics, as described in the table below.

 

PRIMARY LOOP OPTIONS  TABLE 

DIP SWITCH POSITION 

SWITCH 

SETTING 

1 2  3 

ON

 

REPEATING 

TRANSMISSION  

(every 4 sec.)  

UPON PRIMARY  

LOOP FAULT 

Use for high priority  

alarm, such as fire.

 

OFF

 

SINGLE 

TRANSMISSION  

PER PRIMARY 

LOOP CHANGE-

OF-STATE

 

SWITCH MUST 

ALWAYS

 BE 

IN THE 

ON 

POSITION

 

SWITCH MUST  

ALWAYS

 BE 

IN THE  

ON

 

POSITION

 

SWITCH MUST 

ALWAYS

 BE 

IN THE  

OFF

 

POSITION

 

 

Notes:

 

a.  In order for the control panel to enroll the transmitter, the DIP switches must 

be set to OFF – ON – ON – OFF (see Diagram 2). 

 

b.  The Auxiliary loops are not affected by the DIP switch settings. 

UL REQUIREMENT 

1.  If using one of the panel revisions shown in the following table, and programming the 

5817CB as an Entry/Exit zone, you must enroll the tamper loop (loop 4) as a separate 
zone, programmed for 24-hour response (e.g., zone type 5 

 Trouble-by-day/Alarm-by-

night). 

Model # 

Rev. 

EPROM P/N 

FA1600C 8 

(WAVIS150FA-18) 

Vista-32FB 3 (WAVIS32FB-13) 

Vista-128FB 4  (WAVIS128FB-14) 

Vista-128B 3 (WAVIS128B-13) 

 
2.  For UL Commercial Burglary installations, this transmitter must be used in conjunction 

with the 5881ENHC RF Receiver. 

 

WIRING CONNECTIONS 

Connect the loop wiring to the unit's terminals before installing the battery (see Diagram 2).  

Notes

:  

a.  Primary loop 1 is a supervised loop and must have an end-of-line (EOL) resistor 

(470K ohms, supplied) placed across the last sensor. Additionally, for Primary 
loop 1, a contact device may not be installed more than 20 feet from the 
transmitter. 

 

b.   If loop 2 is not going to be used, the magnet is not necessary. 

 

c.  If loop 3 is not going to be used, no connection is needed across its terminals. 

For UL household burglary and fire installations, the loop 3 contact device (if 
used) may not be more than 3 feet from the transmitter. 

 

BATTERY INSTALLATION/REPLACEMENT 

1.  Remove the transmitter's cover as described in Mounting Step 1. 
2.  Observe correct polarity and insert the battery provided into the battery holder 

(see Diagram 2). Take care not to bend the antenna. 

Note

: Replace 

battery 

only with: Duracell DL123A, Sanyo CR123A,  

Panasonic CR123A, Ademco 466, Varta CR123A, or Tekcell CR123A. 

CAUTION:

  Risk of fire, explosion, and burns. Do not recharge, disassemble, 

heat above 212°F (100°C), or incinerate. Dispose of used batteries 
promptly. Keep away from children. 

3. 

To replace the cover, engage the hooks along the top edge and snap shut. 

SPECIFICATIONS 

Dimensions  1-9/16"W x 3-1/2"H x 1-3/16"D (40mm x 89mm x 30mm) 
Battery  3V Lithium (see BATTERY INSTALLATION/REPLACEMENT). 

UL Listings: 

Commercial Fire....................................... UL864 
Household Fire......................................... UL985 
Household Burg ....................................... UL1023 
Commercial Burg ..................................... UL365, UL609, UL1076, UL1610 

TO THE INSTALLER 

Regular maintenance and inspection (at least annually) by the installer and frequent testing 
by the user are vital to continuous satisfactory operation of any alarm system. 

The installer should assume the responsibility of developing and offering a regular 
maintenance program to the user, as well as acquainting the user with the proper operation 
and limitations of the alarm system and its component parts. Recommendations must be 
included for a specific program of frequent testing (at least weekly) to insure the system's 
operation at all times. 

FOR DETAILS ON LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE 
CONTROL PANEL'S
  INSTALLATION INSTRUCTIONS FOR THE RECEIVER/CONTROL WITH 
WHICH THIS DEVICE IS USED. 

 

5817CB-001-V0

MOUNTING

PLATE

HOLE

CASE
HOLDING
POSTS

CONCEALED

WIRING

ENTRY

HOLE

MOUNTING
PLATE HOLES

TAMPER SWITCH

HOLD DOWN

LOCKING
TAB

 

Diagram 1.  Mounting Plate 

+

BATTERY

5817CB-002-V1

DIP

SWITCH

COVER

HOLDING

SLOTS (2)

ANTENNA

COVER

TAMPER

SWITCH

COVER

PRY-OFF

POINT

MOUNTING
PLATE
RELEASE

1/2"

MAX.

N.O.

CONTACT

DEVICE

N.C.

CONTACT

DEVICE

LOOP 3

TERMINALS

(AUX)

ALIGN MAGNET
WITH MARKS ON
CASE (2 PLACES)

MAGNET
(OBTAIN
SEPARATELY)

LOOP 2
REED SWITCH
(AUX)

PRIMARY
LOOP 1
TERMINALS

DIP SWITCH FOR PRIMARY LOOP OPTIONS

(SEE SETTINGS TABLE)

SHOWN SET FOR:  1. SINGLE  TRANSMISSION

NOTE: SW2 MUST BE ON

ON

OFF

ON

1   2   3   4

WHITE AREA
INDICATES
SWITCH HANDLE

THE DIP SWITCHES MUST BE
SET AS SHOWN DURING 
ENROLLMENT BY THE CONTROL

SLOT FOR

CONCEALED

WIRING ACCESS

SW3 MUST BE ON 
SW4 MUST BE OFF

EOLR

470K ohms

 

Diagram 2.  Transmitter, Cover Removed 

NOTE:

 For UL commercial and household fire 

installations, only one initiating device may be 
connected to this transmitter. For UL commercial 
burglary installations, multiple initiating devices 
may be used as long as the devices all service 
the same function such as door/window contacts, 
motion or glassbreak detectors. All initiating 
devices must be located within the same room.  

Отзывы: