ADEL S.r.l. – BCR Barcode / Contactless reader - User Manual Rev. 1.3
pag. 7
5.1.4
I/O SIGNAL CONNECTOR
Besides the I/O signals present on the I/O 1 connector, on the I/O 2 connector an input digital signal and a
power output signal are available and ideal to drive a ralay.
The I/O 2 (JST PH 4x1 PM 90°) connector pinout is the following:
Pin 1 OUT 3B
Pin 2 GNDPP
Pin 3 IN 3B
Pin 4 GND
5.1.5
OPTO #3 CONNECTOR
On the OPTO #3 connector the connection for a optional external optical sensor is available.
The OPTO #3 (JST PH 4x1 PM 90°) connector pinout is the following:
Pin 1 VCC
Pin 2 OSC
Pin 3 VCC
Pin 4 OPTO
5.1.6
STEPPING MOTOR CONNECTOR
The connection of the stepping motor occurs by the means of the connector MOTOR (AMP MODII 4 PM
90°) with the following pinout
Pin 1 OUT 1
Pin 2 OUT 2
Pin 3 OUT 3
Pin 4 OUT 4
5.1.7
SCANNER CONNECTOR
The laser scanner is connected to the CPU board by the means of the connector BCR (JST PH 4x1 PM 90°)
with the following pinout:
Pin 1 VCC
Pin 2 GND
Pin 3 LASER_TRIGGER
Pin 4 TX
5.1.8
CONTACLESS MODULE CONNECTOR
The contactless module is connected to the CPU board by the means of the connector C_LESS (JST PHD
2x5 PM 90°) with the following pinout:
Pin 1 VCC
Pin 2 Rx1
Pin 3 Rx1_RS232
Pin 4 Tx1
Pin 5 Tx1_RS232
Pin 6 I/O AUX1B
Pin 7 C_GND
Pin 8 C_GND
Pin 9 I/O AUX0B
Pin 10 I/O AUX2B
Following drawing and form show the pinout of the connector that must be inserted in the contactless