Evaluation of the Body Mass Index 

Compare the determined value which corresponds to those being used by the WHO. 

BMI below 18,5 

 

The patient is under the regular standard and does not got enough weight. An increase of 
weight is recommended. Please consult a professional. 

BMI between 18,5 and 24,9 

 

The patient got a normal weight. If he feels well there is no need for a change. 

BMI between 25 and 30 

 

The patient is slightly overweighed to pre-obese. A reduction of weight is indicated or, is 
necessary if the state of health is already affected (e.g. diabetes, high end blood pressure, 
heart diseases). 

BMI over 30 

 

Reduction of weight is imperative. To visit a doctor is highly recommended. 

Connecting additional devices 

Connection of printer, PC or remote-display will be done with the RS-232 interface. For connection of 
additional devices kindly ask your local representative or authorized ADE dealer for further instructions. 

Print out a record 

The scales must be at standstill. The standstill status symbol 

 must appear at the screen. Press the 

ENTER key to send the data to the serial interface.  

Note: Printing is not possible if the net weight is 0. The print function only produces one print-out. A reset 
is required to print out another copy.  

Error Messages 

Error Codes 

Description 

Solution 

 

 

Load cell wires to indicator are 
incorrectly connected; or shorted, or 
opened; or ADC/ load cell are being 
damaged  

Make sure wires are in good order 
and condition and correctly 
connected. Replace load cell or 
ADC chip. Service is required.

 

 

 

Weight reading exceeds the zero limit 
after switching the scale on. 

Make sure scale platform is empty. 

 

Weight reading is below the zero limit 
after switching the scale on. 

Install platform on scale. 
Otherwise the zero calibration/ 
adjustment have to be done by 
authorized personnel. 

 

Weight reading exceeds load limit.  

Reduce load on scale until weight 
value can be displayed.  

 

Weight reading below load limit. 

Service by authorized personnel 
required. 

 

Configuration or Calibration parameters 
are not correctly set. 

Contact your local dealer / supplier 
for calibration purpose. 

 

 

Содержание M501660

Страница 1: ...Operating Manual International Range Electronic Wheelchairs M501660 M501660 210512 Rev003 UM e...

Страница 2: ...escription 4 Key Description 5 Weighing 5 Correct weighing 5 How to change the unit 5 Tare function 6 Weighing with preset tare values 6 HOLD function 6 BMI Body Mass Index 6 Evaluation of the Body Ma...

Страница 3: ...ly follow the safety instructions in this operating manual the country specific installation standards as well as the applicable safety conditions and accident prevention regulations in all aspects Op...

Страница 4: ...IMH rechargeable batteries Use the AC adapter to load the rechargeable batteries The imprinted voltage value at the mains adapter must match the local mains voltage When the battery is being charged f...

Страница 5: ...dstill status indicator 14 The scale is at a standstill meaning the weight is stable and no movement is on the platform This is a mandatory precondition for functions such as resetting printing and ta...

Страница 6: ...g Correct weighing Press the start key ON OFF to enter the normal operating mode of the scale with no load on the platform An automatic function test will be performed as well as the zero setting of t...

Страница 7: ...appear at the display and ignored by the scale HOLD function The Hold function is being used if you like to hold the results at the display after the weight load has been removed from the scale Use t...

Страница 8: ...t a record The scales must be at standstill The standstill status symbol must appear at the screen Press the ENTER key to send the data to the serial interface Note Printing is not possible if the net...

Страница 9: ...trating the scale Storage and Transport Please keep all original parts and pieces for an eventual sending back of the scale in order to avoid any possible damage during transport which automatically l...

Страница 10: ...00mA Central negative 4xAA NIMH rechargeable batteries pack Display 6 digit 7 segment 1 25mm LCD with 16 annunciators and blue backlight Working temperature 10 C to 40 C Storage temperature 20 C to 70...

Страница 11: ...ity by the manufacturer These scales have been manufactured in accordance with the harmonised European standards They conform to the regulations of the EC directives listed below EMC Directive 2014 30...

Страница 12: ...11 M501660 210512 Rev003 UM e authorised dealer...

Отзывы: