Introduction 

 

This symbol means: "Consult operating instructions". To achieve accurate results, read 
the instructions for use carefully before use and follow all instructions provided therein. 
Keep the instructions for use for future reference. 

Your  ADE  electronic  wheelchair-scale  is  a  quality,  sturdy  and  durable  product  manufactured  in 
accordance with German national regulations.  

ADE  instruction  manuals  have  been  prepared  to  provide  the  user  with  all  the  necessary  knowledge 
about the safe use of ADE scales and their related accessory equipment.  

For further questions about how to use the products or about this or other service manuals, feel free to 
contact your local ADE representative or visit our web page at www.ade-hamburg.de. 

In order to achieve the best possible results kindly read and follow the operation manual in all respects. 

Check carton contents 

Weighing platform 

Display plus connecting cable 

Wall bracket already assembled to the display 

Mains adapter 

Operating Manual  

Safety 

The ADE-display unit corresponds to the latest state of the art technology and complies with standard 
regulations and directives. Kindly follow the safety instructions in this operating manual, the country-
specific installation standards as well as the applicable safety conditions and accident prevention 
regulations in all aspects.  

 

Operate the scale only with the original ADE mains adapter.

 

 

Always connect the mains adapter to the scale 

BEFORE

 connecting it to the electrical outlet . 

 

Disconnect from the electrical outlet 

BEFORE

 disconnecting the adapter from the scale.

 

 

In case the mains adapter became wet or show visible damages the scale can no longer be 
operated by using this mains adapter. In this case please contact your local dealer or service 
partner. 

 

The voltage and power supply as mentioned on the type plate must match the mains voltage 
and power type at the place of use. 

 

When using the scale with a mains unit ensure that the supply cable is routed in such a way as 
to exclude any type of potential trip hazard. 

 

Remove the mains plug before cleaning the unit. 

 

Do not operate the unit in hazardous or unstable conditions. 

 

Set up the unit as far away as possible from equipment that generates electromagnetic or 
other interference. Portable and mobile HF-communication systems may influence electronic 
medical devices 

 

All actions and operations described in this operation manual may only be carried out by 
professional personnel authorized by ADE or official appointed dealers. 

 

 

 

Содержание M501660

Страница 1: ...Operating Manual International Range Electronic Wheelchairs M501660 M501660 210512 Rev003 UM e...

Страница 2: ...escription 4 Key Description 5 Weighing 5 Correct weighing 5 How to change the unit 5 Tare function 6 Weighing with preset tare values 6 HOLD function 6 BMI Body Mass Index 6 Evaluation of the Body Ma...

Страница 3: ...ly follow the safety instructions in this operating manual the country specific installation standards as well as the applicable safety conditions and accident prevention regulations in all aspects Op...

Страница 4: ...IMH rechargeable batteries Use the AC adapter to load the rechargeable batteries The imprinted voltage value at the mains adapter must match the local mains voltage When the battery is being charged f...

Страница 5: ...dstill status indicator 14 The scale is at a standstill meaning the weight is stable and no movement is on the platform This is a mandatory precondition for functions such as resetting printing and ta...

Страница 6: ...g Correct weighing Press the start key ON OFF to enter the normal operating mode of the scale with no load on the platform An automatic function test will be performed as well as the zero setting of t...

Страница 7: ...appear at the display and ignored by the scale HOLD function The Hold function is being used if you like to hold the results at the display after the weight load has been removed from the scale Use t...

Страница 8: ...t a record The scales must be at standstill The standstill status symbol must appear at the screen Press the ENTER key to send the data to the serial interface Note Printing is not possible if the net...

Страница 9: ...trating the scale Storage and Transport Please keep all original parts and pieces for an eventual sending back of the scale in order to avoid any possible damage during transport which automatically l...

Страница 10: ...00mA Central negative 4xAA NIMH rechargeable batteries pack Display 6 digit 7 segment 1 25mm LCD with 16 annunciators and blue backlight Working temperature 10 C to 40 C Storage temperature 20 C to 70...

Страница 11: ...ity by the manufacturer These scales have been manufactured in accordance with the harmonised European standards They conform to the regulations of the EC directives listed below EMC Directive 2014 30...

Страница 12: ...11 M501660 210512 Rev003 UM e authorised dealer...

Отзывы: