Introduction 

 

This  symbol  means:  "Consult  operating  instructions".  To  achieve  accurate  results,  read  the 
instructions for use carefully before use and follow all instructions provided therein. Keep the 
instructions for use for future reference. 

 

Your  ADE  electronic chair-scale is a quality, sturdy and durable product manufactured under the  high stand-
ards  and  regulations  for  calibrated  class  III  scales  in  accordance  with  national  regulation  in  Germany.  The 
scale 

is designed and manufactured for the daily practice in hospitals, doctors’ surgeries and in-patient nursing 

facilities.

  

ADE instruction manuals have been prepared to provide the user with all the necessary knowledge about the 
safe use of ADE scales and their related accessory equipment.  

For further questions about how to use the products or about this or other service manuals, feel free to contact 
your local ADE representative or visit our web page at www.ade-hamburg.de  

In order to achieve the best possible results kindly read and follow the operation manual in all respects. 

Assembly and set up 

The ADE chair scale is already been delivered in a fully assembled condition. Please insure that your scale is 
being placed vibration free at a dry place.  
 

Alignment of the scale

 

 
1) Place the chair scale on a plain, dry and level surface before the weighing of patients. 
3) The air bubble in the spirit level should be right in the centre of the circle 
4) Please ensure that the scale has no other contact to the floor than by the four wheels after the patient has 
been seated onto the chair scale. 

Power supply 

Power is supplied either by the rechargeable battery in the display unit or by the mains power via the supplied 
power unit. The imprinted voltage value at the mains adapter must match the local mains voltage. 

After checking same connect the mains cable to the indicator and to a socket.  

 

Note:  The  wall  socket  must  be  located  near  to  the  unit  and  be  easily  accessible.  Please  use  only  the  mains 
adapter supplied by ADE. The mains adapter is charging the battery pack at the same time. 

 

When the battery is being charged for the first time a sufficient charging period of approx. 24 hours is neces-
sary to achieve a full battery load. 

In  case  the  scale  is  being  used  with  batteries  only  and  the  display  indicates  – 

Lo

,  the  battery  should  be  re-

charged with the ADE mains adapter. After the first charging period the battery need 12-16 hours. The battery 
should be charged while the scale is switched off. Upon completion of the charging period switch the scale on 
again to check the battery status. In case  

Lo

- still appears on the display inform your service partner. 

Содержание M403020

Страница 1: ...Operating Manual Class III Approved Scales Electronic Chair Scales M403020 M403020 210322 Rev006 UM e...

Страница 2: ...ting additional devices 6 Housing and connections 7 Modes of operation 7 Settings 7 Setting date and time 8 Operation 8 Positioning of patient 8 Weighing 8 Resetting the scales back to zero 8 Tare fun...

Страница 3: ...ee at a dry place Alignment of the scale 1 Place the chair scale on a plain dry and level surface before the weighing of patients 3 The air bubble in the spirit level should be right in the centre of...

Страница 4: ...are supplied only in partial charged condition Some batteries only achieve their full capaci ty after several complete charge and discharge cycles When disposing of disused batteries observe the valid...

Страница 5: ...for a long period to enter and save the tare value 11 BMI Button Enter to proceed with BMI mode and to enter as next step the height Press again to return to weight mode 12 Units Button Switch button...

Страница 6: ...Only use approved accessories and peripheral equipment Only operate the unit under permitted ambient conditions Remove the mains plug before cleaning the unit Do not operate the unit in hazardous or u...

Страница 7: ...ommands are being set in this mode To start setting mode hold the GROSS NET key pressed until TIME appears on the display Configuration mode set up mode The values for different parameters including t...

Страница 8: ...t position before patient stand up again Armrest and footrest are not to be used as helping device for getting up from the chair They are to be understood as supporting device for arms and legs only i...

Страница 9: ...shown corresponds to the gross weight minus the tare value If there is no tare value saved the display remains in gross mode The tare value flashes briefly then after a second the display changes to...

Страница 10: ...rflow indicator negative Negative weight indicated weight too low to be displayed 99999 Overflow indicator positive Positive weight indicated weight too high to be displayed 999999 AD LOW A D above ne...

Страница 11: ...materials or workmanship All movable parts e g batteries cables power units etc are excluded This warranty does not cover any normal external appearance of use and wear or any damage occurring as a re...

Страница 12: ...t Full duplex RS 232 38400 19200 9600 4800 2400 1200 bps Printer Port Output only RS 232 or active 20 mA current loop 9600 4800 2400 1200 bps Both Ports 7 or 8 data bits even odd or no parity Operator...

Страница 13: ...formity by the manufacturer This product has been manufactured in accordance with the harmonised European standards They con form to the regulations of the EC directives listed below NAWI Directive 20...

Страница 14: ...14 M403020 210322 Rev006 UM e...

Страница 15: ...M403020 210322 Rev006 UM e 15...

Страница 16: ...16 M403020 210322 Rev006 UM e Dealer...

Отзывы: