ADE HWZ Series Скачать руководство пользователя страница 10

10 

 

HWZ-190214-Rev006-UM-en 

 

You can add more products. To do this, press 

 

 each time. This process can save up to 99 

entries or the full capacity of the “Weight” window. 

 

To view the saved total value, press the 

 key. The total sum is displayed for 2 seconds. 

 

To print the total number of units, first press 

 and then 

. The prerequisite is the optional 

RS232 data interface. 

 

To clear the memory, first press 

 to view the total sums and then press the 

 key to clear 

all values from memory. 

 

8.4.5  Automatic totaliser 

 

The scale can be set to automatically add total sums when a weight is placed on the scale. It is 

no longer necessary to press the 

 

 key to save values. However, the 

 

 key is still active 

and  can  be  pressed  to  save  the  values  immediately.  In  this  case,  the  values  will  no  longer  be 
saved when the scale returns to zero. 

 

See section 9 (parameters) for details on setting the automatic totaliser. 

 

9. 

Backlight and parameter setting 

9.1 

Backlight of the LCD display 

 

The backlight of the LCD display can be set to be permanently on; it can also only be switched on 
when a weight is on the scale; or it can be turned off. 

 

To adjust the backlight, press and hold down the 

 key for 6 seconds. 

 

The “Weight” window shows the current setting for the backlight “EL xx”. 

EL Au

 

Automatic backlight when a weight is placed on the scale or when a key is pressed. 

EL OFF

  Switching off the backlight. 

EL On

 

Permanent activation of the backlight 

 

Press the 

 key to select the desired setting. 

 

Confirm with 

 

9.2 

Scale-specific parameters 

 

To set the parameters, go to a saved menu. To do this, you have to enter a code. 

 

To set the parameter menu, press the 

 key during the test run of the display after switching 

on. 

 

The “Weight” window shows “PLn”: Enter your code. 

 

The default code is “0000”. With the help of the parameter menu (see below) it can be changed 

as desired. Press 

 key 4 times and confirm with the 

 key. 

 

The parameter menu has 11 functions. To navigate through these functions, press the 

 key. 

The “Weight” window shows the names of the functions. To select a function, press the 

 key. 

To navigate through the values of this function, press 

. Press 

 to save the selection. 

 

You can press the 

 key at any time to return to weighing mode. 

Содержание HWZ Series

Страница 1: ...ounting scale of HWZ series HWZ 190214 Rev006 UM en ADE Germany GmbH Co KG Hammer Steindamm 27 29 22089 Hamburg GERMANY 49 0 40 432776 0 49 0 40 432776 10 info ade hamburg de IMPORTANT READ CAREFULLY...

Страница 2: ...unit weight 7 8 3 2 Weighing a sample to determine the unit weight 8 8 3 3 Entering a known unit weight 8 8 4 Counting more units 8 8 4 1 Automatic update of the unit weight 9 8 4 2 Presetting the max...

Страница 3: ...s However improper use may cause personal injury and dam age to property Read the operating manual carefully before putting the device into operation This will prevent damage to the device Keep the op...

Страница 4: ...through a test programme and acknowledges the end of the routine with an acoustic signal If the weighing platform is loaded when switching on the scale the scale will not be properly calibrated and re...

Страница 5: ...al sounds Print key Used to print the totaliser when connected to a printer or PC Requirement Optional RS232 data interface is installed Count key Used to enter the number of units Sample weight key U...

Страница 6: ...r to warn the user of a potential problem If a preset number of units has been saved a small arrow appears above the symbol 7 3 Count window COUNT This window shows the number of units on the scale or...

Страница 7: ...econd method This method allows you to enter a value for the tare weight using the keypad This is useful when you are using the same containers or when the container is already full while the net weig...

Страница 8: ...f the weight is below zero the Count window shows a negative number of units 8 3 3 Entering a known unit weight If the unit weight is already known this value can be entered using the keypad Enter the...

Страница 9: ...Use the 10 key keypad to enter the minimum weight at which an acoustic signal should sound and confirm with the key You will now return to weighing mode To delete the preset values from the memory an...

Страница 10: ...e set to be permanently on it can also only be switched on when a weight is on the scale or it can be turned off To adjust the backlight press and hold down the key for 6 seconds The Weight window sho...

Страница 11: ...the key to navigate through the options The value can be set to 0 5d 1d 2d or 4d Normally it is set to 1d but it can be increased in order to zero the scale if there is a small amount of material spil...

Страница 12: ...plug the power adapter into the scale and switch on the mains voltage The scale does not need to be switched on The rechargeable battery must be charged for 12 hours to its full capacity There is an...

Страница 13: ...hing range when the scale is switched on or when the key is pressed The weighing platform has already been loaded when the scale has been switched on Weighing platform overload when the scale is set t...

Страница 14: ...belong in the domestic waste Please dispose of defective or old products and batteries with the legal and au thorised channels Please make sure that only discharged batteries or batteries with insulat...

Страница 15: ...ically 2 seconds Operating tempera ture 0 C 40 C Protection type IP34 Power supply 6 DC 4 AH cold device power cord via 230 V power connection Calibration With external weight Indicator Three 6 digit...

Страница 16: ...in accordance with the harmonised European standards It conforms to the provisions of the EC directives cited below EMC Directive 2014 30 EU regarding electromagnetic compatibility Low voltage directi...

Страница 17: ...HWZ 190214 Rev006 UM en 17...

Страница 18: ...18 HWZ 190214 Rev006 UM en...

Страница 19: ...HWZ 190214 Rev006 UM en 19...

Страница 20: ...20 HWZ 190214 Rev006 UM en Distributor...

Отзывы: