Note:

When replacing the PCB align it

on the round support pillars to the
bottom and allow it to click down past
the clips at the top of the case. Refit the
transformer wires into the terminal.

b.

Fit the panel to the wall with suitable
fixings. Ensure the wall surface is flat to
prevent base distortion. There are
cable entry holes provided in the rear
of the base and around the outside
edges through the thinned out plastic
sections which may be cut away as
required.

c.

The hole provided adjacent to the
mains transformer is a dedicated mains
cable entry point.

Board

There are four fuses mounted on the circuit
board, all are 20mm quick blow.
F1 1.6A - to protect the +ve line of 12V battery
F2 1A - to protect the RKP 13V supply
F3 1A - to protect the Speaker 13V supply
F5 1A - to protect the Bell and Strobe supply

As supplied, wire links are fitted across the PA
and Tamper terminals to represent a closed
circuit.

4

4PI175 issue 1_6/01

Engineering information

Accenta/Optima G3 Intruder system

Fixing

J2

PA

+

TAMP

-

+13V 0V

-

STROBE

J6

+

-

AC

TAMP

+

T A

SCB

D

B

BELL

+

-

SET

1A

1A

1.6A

BELL/STROBE

13V

/

SPEAKER

BA

TTER

Y

BATT

J4

F1

F3

F5

J5

0V

TAMP

+13V

COMMS

SOUND

VR1

VOLUME

2

1

4

3

6

5

8

7

1A

RKP FUSE

F2

ABORT

J3

+13V

L/FAIL

0V FIRE PA

INT SET

CONF

Factory fitted links

0

1

2

3

5

6

7

8

CHIME

OMIT

RESET

4

9

SET

PROG

Communicator is not fitted
to Optima compact G3 panel

Keypad and LEDs (except Power LED) are not
fitted to Accenta G3 and Accenta mini G3 panels

D1

D2

D3

D4

D5

D6

D7

D8

D9

D10

D22

D18

Mounting holes

Mounting holes

Cable entry

holes



‚

ƒ

Содержание Accenta G3

Страница 1: ...Optima compact G3 panel with built in keypad Attack Tamper Day 1 2 3 4 5 6 7 8 Power Accenta mini 0 1 2 3 5 6 7 8 Chime Omit Reset 4 9 Set Prog PA Attack Tamper Day 1 2 3 4 5 6 7 8 Power Accenta mini...

Страница 2: ...t in keypad 2 4PI175 issue 1_6 01 Engineering information Accenta Optima G3 Intruder system Features Contents Features 2 Installation Design 3 Fixing 3 Wiring the system 5 Tamper network 5 Connect Rem...

Страница 3: ...able the system operator to check that the system is setting correctly Finally note that the total current output of this control system in alarm condition is 1Amp when supported by a fully charged ba...

Страница 4: ...he ve line of 12V battery F2 1A to protect the RKP 13V supply F3 1A to protect the Speaker 13V supply F5 1A to protect the Bell and Strobe supply As supplied wire links are fitted across the PA and Ta...

Страница 5: ...being installed ensure there is at least one remote keypad wired to the panel before first power up A combination of up to four remote keypads and lighting controller can be connected to the panel Se...

Страница 6: ...to be pressed Fire zone Any zone may be programmed as a fire zone This will automatically exclude the availability of the zone from programs and normal security applications There are two types of fi...

Страница 7: ...position from where the bell could be seen and heard Terminal T A D B are for connection to the external bell or sounder These terminals provide a power hold off supply sounder trigger and tamper circ...

Страница 8: ...s activated when pulled to 0V by the telephone line fault output of the communicator This is usually a voltage free relay or open collector transistor When a telephone line fault occurs in the Day mod...

Страница 9: ...nd abort is being used care should be taken to ensure that the abort connection cannot be damaged or severed as this could cause the ARC to incorrectly filter an alarm signal d It is very important th...

Страница 10: ...unce period 300mS ALL zones Flag A Silent PA No RKP PA Enable Yes Engineer Reset No Anti Code Reset No Door bell on push to set No Single key setting No Strobe on setting No External bell on Fire No F...

Страница 11: ...t by setting them to disabled using the Zone Type function see page 19 Mains Connection The mains power should be connected using a 3 core cable of not less than 0 75mm sq from a fused spur to the mai...

Страница 12: ...Key To exit System indications Unset system indication Set system indication To enter Engineer program mode Note The factory configured engineer s access code is 9999 If however this code is changed...

Страница 13: ...cesses the Engineer Program mode to allow the system to be programmed The engineer code will not set or unset the system If configured the Engineers access code can be used to reset the system after a...

Страница 14: ...allows access to the Entry Exit zone However if the panel is set and an time inhibited zone is triggered before an Entry Exit zone then an alarm will be generated immediately Immediate This is a zone...

Страница 15: ...one 1 Day Day Day Input Entry Exit time respectively 0 1 0 2 0 3 20 seconds duration Acknowledge 10 seconds duration 30 seconds duration factory default Zone n selected Zone n deselected 5 6 7 2 3 4 1...

Страница 16: ...for zone 5 flat x2 for zone 6 flat x4 for zone 8 Rapid for PA Rapid for Tamper Zones Strobe Strobe test 2 Bell test 3 Low volume sounder High volume sounder 4 5 Walk test 6 Strobe On Bell on internal...

Страница 17: ...alarm When the flag is clear the system can be reset by the user Anti code Reset When this flag is set it enables the anti code reset function Enable Door bell on PTS When this flag is set it allows a...

Страница 18: ...s set it configures the polarity of line fail input User Reset PA When this flag is set it permits the user code to reset the system after a PA alarm even if Engineer reset flag is set User Reset Fire...

Страница 19: ...e Zone 6 type Zone 8 type 5 6 8 2 3 4 1 5 Attack All Zones Press a number button to select Zone to be configured Press a number button to select zone type Day Exit to zone type Exit zone configuration...

Страница 20: ...ributes Zone Attributes Double Knock Omit Prevent Zone Delay 2 3 1 6 Attack Zone n selected Zone n deselected 5 6 7 2 3 4 1 8 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Press number butto...

Страница 21: ...uration 2 minute bell duration Acknowledge 100 Set Unset 1 Zone 1 Press a number button to select Service timer 300 Set Unset 3 Zone 3 200 Set Unset 2 Zone 2 500 Set Unset 5 Zone 5 400 Set Unset 4 Zon...

Страница 22: ...it anti code would be given to the user which would reset the system This anti code is generated from a small computer program which is installed at most UK Alarm receiving Centres or alternatively ca...

Страница 23: ...l All Zones 5 6 7 2 3 4 1 8 To assign zones to channel press to select and again to deselect zone Factory default No zones are selected Zone n assigned to the channel Zone n not assigned to the channe...

Страница 24: ...the tamper wiring When measured with a multimeter the series resistance between the zone and tamper wiring should be infinitely high f If totally lost as to the cause of a fault remove ALL wiring fro...

Страница 25: ...Alarm 70mA Low voltage output 13 8V dc stabilised 5 up to 350mA Rechargeable Battery Accenta Optima G3 mini compact 12V 1 2 or 2 1Ah Accenta Optima G3 12V up to 7Ah Charge Voltage 13 8V dc 5 PCB Fuse...

Страница 26: ...0 23 Line Fail 10 Local Authorit 3 M Mains 11 25 Managers code 13 N NACOSS 6 9 NACP 14 9 Normally closed detectors 24 Normally open detector 24 NVM 2 9 O Omit prevent 10 20 Operating temperature 25 P...

Страница 27: ...SP 400 Accenta mini G3 panel 8EP 395 Optima G3 8EP 396 Optima compact G3 panel 8EP 219 Accenta LED RKP 8EP 332 Accenta LCD RKP 8EP 336 Accenta Speech Dialler 8EP 276 Informa 8EP 289 Extension Speaker...

Страница 28: ...2 3 4 1 4 Zone Attributes see page 20 Double Knock Omit Prevent Zone Delay 2 3 1 6 Strobe test 2 Bell test 3 Low volume sounder High volume sounder 4 5 6 9 9 9 9 Engineer Program Mode Prog To exit eng...

Страница 29: ...have only the Power indicator lit This is an armed system indication 4PI175 issue 1_6 01 1 Unset system indications 0 1 2 3 5 6 7 8 Chime Omit Reset 4 9 Set Prog ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZO...

Страница 30: ...ll of the zones and become Set as the user leaves the property and closes the final door Program 2 To protect the perimeter of the property in the evening and become Set after say 20 seconds Program 3...

Страница 31: ...it the sounder will produce an open zone tone and the fault will be displayed Either re enter your code to turn off and investigate or omit the faulty zone s from the system How to unset the system t...

Страница 32: ...et When a zone that is set to chime is operated the internal sounder will produce a low volume two stage warning tone and the Zone indicator will show The indicator may be cancelled by pressing Reset...

Страница 33: ...scroll starts with the newest event number 8 to the oldest one number 1 4PI175 issue 1_6 01 5 Accenta Optima G3 intruder system Operating instructions Operator s Program mode Reset Quit the current f...

Страница 34: ...n n n New code Or Omit To omit the user 2 code ZONE 1 4 Rising beeps Attack Leave program mode Day Tamper Attack Acknowledge NOTE The sounder will produce a flat beep if code is rejected Enter Operat...

Страница 35: ...one 5 Zone 6 Zone 7 Zone 8 T Timed Entry Exit Zone TI Time Inhibited Access zone to keypad I Immediate All zones armed to give full alarm 4PI175 issue 1_6 01 7 Accenta Optima G3 intruder system Operat...

Страница 36: ...m Set the system or Set a Program and while the system is setting ZONE S TO BE ARMED n Press the zone s to be omitted ZONE S TO BE OMITTED Exit beep Exit beep 10 seconds insistent beeps Day ARC o p Se...

Отзывы: