ADE Accenta G3 Скачать руководство пользователя страница 32

How to Quick set

During the exit period (on entering User code)

the system may be Set
quickly by pressing Set.
This removes the exit time
period.

If you omit zones and
require Quick Set, you will
need to press Set twice.

How to Omit zone(s) on setting

system

During the exit period after entering User code

and selecting a
program press
OMIT, the exit tone
will stop and zones
that are about to be
armed will be
displayed. Key in
the zone number(s)
to be omitted which
will flash to confirm
selection. Zone
indicators which
show steady are still
about to be armed.
When the selection
is complete press
Set and the exit tone
will start.

If a zone refuses to be omitted, it may be
because the engineer has programmed the panel
to prevent you from turning off the zone. If in
doubt ask your installer for advice.

Fire Alarm

The fire zone will operate on detection of a fire,
whether the system is Set or Unset, when
configured as a 24 hour zone, and cause a
distinctive internal sounder tone. The external
sounders will pulse on and off at 2 second
intervals and all keypad indicators will flash to
attract attention.

How to set Chime Zones

Chime is a low security monitoring system for
use when the system is Unset. When a zone that
is set to chime is operated, the internal sounder
will produce a low volume two stage warning
tone and the Zone indicator will show. The
indicator may be cancelled by pressing Reset.
Chime is particularly useful in a shop to warn of
a customer presence or in a house to warn that a
door or particular area has been accessed.

Any zone may set to be on or off chime by
pressing the CHIME key and then keying in the
required zone number(s). Key 0 to cancel all
zones from chime. After a few seconds the
system will automatically return to the Day
mode.

4

4PI175 issue 1_6/01

Operating instructions

Accenta/Optima G3 Intruder system

How

to

Quick

set

Set

Set the system or
Set a Program

Day

Day

5 seconds
insistent beeps

ARC

o/p

Set output

Set

Omit

Day

Set the system or
Set a Program and while the
system is setting:

ZONE(S) TO BE ARMED

n

Press the zone(s)
to be omitted

ZONE(S) TO BE OMITTED

Exit beep

Exit beep

10 seconds
insistent beeps

Day

ARC

o/p

Set output

Chime

Reset

Day

Day

Timeout after 5 seconds if
no selection is made

Chime

5

6

7

2

3

4

1

8

Press

number

button

to

select

/

deselect

Zone

Chime

0

Deselect all zones
(Factory default - no chime)

Zone n
Chime selected

Zone n
Chime deselected

Zone 1

Zone 2

Zone 3

Zone 4

Zone 5

Zone 6

Zone 7

Zone 8

Appropriate
Zone indicator
is lit to show
chime zone(s)

Leave chime mode

Day

Example: To set zone 3 and 4 to
chime, Press:

Chime

3

4

Reset

Содержание Accenta G3

Страница 1: ...Optima compact G3 panel with built in keypad Attack Tamper Day 1 2 3 4 5 6 7 8 Power Accenta mini 0 1 2 3 5 6 7 8 Chime Omit Reset 4 9 Set Prog PA Attack Tamper Day 1 2 3 4 5 6 7 8 Power Accenta mini...

Страница 2: ...t in keypad 2 4PI175 issue 1_6 01 Engineering information Accenta Optima G3 Intruder system Features Contents Features 2 Installation Design 3 Fixing 3 Wiring the system 5 Tamper network 5 Connect Rem...

Страница 3: ...able the system operator to check that the system is setting correctly Finally note that the total current output of this control system in alarm condition is 1Amp when supported by a fully charged ba...

Страница 4: ...he ve line of 12V battery F2 1A to protect the RKP 13V supply F3 1A to protect the Speaker 13V supply F5 1A to protect the Bell and Strobe supply As supplied wire links are fitted across the PA and Ta...

Страница 5: ...being installed ensure there is at least one remote keypad wired to the panel before first power up A combination of up to four remote keypads and lighting controller can be connected to the panel Se...

Страница 6: ...to be pressed Fire zone Any zone may be programmed as a fire zone This will automatically exclude the availability of the zone from programs and normal security applications There are two types of fi...

Страница 7: ...position from where the bell could be seen and heard Terminal T A D B are for connection to the external bell or sounder These terminals provide a power hold off supply sounder trigger and tamper circ...

Страница 8: ...s activated when pulled to 0V by the telephone line fault output of the communicator This is usually a voltage free relay or open collector transistor When a telephone line fault occurs in the Day mod...

Страница 9: ...nd abort is being used care should be taken to ensure that the abort connection cannot be damaged or severed as this could cause the ARC to incorrectly filter an alarm signal d It is very important th...

Страница 10: ...unce period 300mS ALL zones Flag A Silent PA No RKP PA Enable Yes Engineer Reset No Anti Code Reset No Door bell on push to set No Single key setting No Strobe on setting No External bell on Fire No F...

Страница 11: ...t by setting them to disabled using the Zone Type function see page 19 Mains Connection The mains power should be connected using a 3 core cable of not less than 0 75mm sq from a fused spur to the mai...

Страница 12: ...Key To exit System indications Unset system indication Set system indication To enter Engineer program mode Note The factory configured engineer s access code is 9999 If however this code is changed...

Страница 13: ...cesses the Engineer Program mode to allow the system to be programmed The engineer code will not set or unset the system If configured the Engineers access code can be used to reset the system after a...

Страница 14: ...allows access to the Entry Exit zone However if the panel is set and an time inhibited zone is triggered before an Entry Exit zone then an alarm will be generated immediately Immediate This is a zone...

Страница 15: ...one 1 Day Day Day Input Entry Exit time respectively 0 1 0 2 0 3 20 seconds duration Acknowledge 10 seconds duration 30 seconds duration factory default Zone n selected Zone n deselected 5 6 7 2 3 4 1...

Страница 16: ...for zone 5 flat x2 for zone 6 flat x4 for zone 8 Rapid for PA Rapid for Tamper Zones Strobe Strobe test 2 Bell test 3 Low volume sounder High volume sounder 4 5 Walk test 6 Strobe On Bell on internal...

Страница 17: ...alarm When the flag is clear the system can be reset by the user Anti code Reset When this flag is set it enables the anti code reset function Enable Door bell on PTS When this flag is set it allows a...

Страница 18: ...s set it configures the polarity of line fail input User Reset PA When this flag is set it permits the user code to reset the system after a PA alarm even if Engineer reset flag is set User Reset Fire...

Страница 19: ...e Zone 6 type Zone 8 type 5 6 8 2 3 4 1 5 Attack All Zones Press a number button to select Zone to be configured Press a number button to select zone type Day Exit to zone type Exit zone configuration...

Страница 20: ...ributes Zone Attributes Double Knock Omit Prevent Zone Delay 2 3 1 6 Attack Zone n selected Zone n deselected 5 6 7 2 3 4 1 8 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Press number butto...

Страница 21: ...uration 2 minute bell duration Acknowledge 100 Set Unset 1 Zone 1 Press a number button to select Service timer 300 Set Unset 3 Zone 3 200 Set Unset 2 Zone 2 500 Set Unset 5 Zone 5 400 Set Unset 4 Zon...

Страница 22: ...it anti code would be given to the user which would reset the system This anti code is generated from a small computer program which is installed at most UK Alarm receiving Centres or alternatively ca...

Страница 23: ...l All Zones 5 6 7 2 3 4 1 8 To assign zones to channel press to select and again to deselect zone Factory default No zones are selected Zone n assigned to the channel Zone n not assigned to the channe...

Страница 24: ...the tamper wiring When measured with a multimeter the series resistance between the zone and tamper wiring should be infinitely high f If totally lost as to the cause of a fault remove ALL wiring fro...

Страница 25: ...Alarm 70mA Low voltage output 13 8V dc stabilised 5 up to 350mA Rechargeable Battery Accenta Optima G3 mini compact 12V 1 2 or 2 1Ah Accenta Optima G3 12V up to 7Ah Charge Voltage 13 8V dc 5 PCB Fuse...

Страница 26: ...0 23 Line Fail 10 Local Authorit 3 M Mains 11 25 Managers code 13 N NACOSS 6 9 NACP 14 9 Normally closed detectors 24 Normally open detector 24 NVM 2 9 O Omit prevent 10 20 Operating temperature 25 P...

Страница 27: ...SP 400 Accenta mini G3 panel 8EP 395 Optima G3 8EP 396 Optima compact G3 panel 8EP 219 Accenta LED RKP 8EP 332 Accenta LCD RKP 8EP 336 Accenta Speech Dialler 8EP 276 Informa 8EP 289 Extension Speaker...

Страница 28: ...2 3 4 1 4 Zone Attributes see page 20 Double Knock Omit Prevent Zone Delay 2 3 1 6 Strobe test 2 Bell test 3 Low volume sounder High volume sounder 4 5 6 9 9 9 9 Engineer Program Mode Prog To exit eng...

Страница 29: ...have only the Power indicator lit This is an armed system indication 4PI175 issue 1_6 01 1 Unset system indications 0 1 2 3 5 6 7 8 Chime Omit Reset 4 9 Set Prog ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZO...

Страница 30: ...ll of the zones and become Set as the user leaves the property and closes the final door Program 2 To protect the perimeter of the property in the evening and become Set after say 20 seconds Program 3...

Страница 31: ...it the sounder will produce an open zone tone and the fault will be displayed Either re enter your code to turn off and investigate or omit the faulty zone s from the system How to unset the system t...

Страница 32: ...et When a zone that is set to chime is operated the internal sounder will produce a low volume two stage warning tone and the Zone indicator will show The indicator may be cancelled by pressing Reset...

Страница 33: ...scroll starts with the newest event number 8 to the oldest one number 1 4PI175 issue 1_6 01 5 Accenta Optima G3 intruder system Operating instructions Operator s Program mode Reset Quit the current f...

Страница 34: ...n n n New code Or Omit To omit the user 2 code ZONE 1 4 Rising beeps Attack Leave program mode Day Tamper Attack Acknowledge NOTE The sounder will produce a flat beep if code is rejected Enter Operat...

Страница 35: ...one 5 Zone 6 Zone 7 Zone 8 T Timed Entry Exit Zone TI Time Inhibited Access zone to keypad I Immediate All zones armed to give full alarm 4PI175 issue 1_6 01 7 Accenta Optima G3 intruder system Operat...

Страница 36: ...m Set the system or Set a Program and while the system is setting ZONE S TO BE ARMED n Press the zone s to be omitted ZONE S TO BE OMITTED Exit beep Exit beep 10 seconds insistent beeps Day ARC o p Se...