Installing the indoor unit

Positioning the mounting plate

Install directly on the wall

Select a structural part of the wall, so that indoor unit can be installed
securely.

Make sure the mounting plate is level before securing it.

The wall must be capable of carrying the weight of the indoor unit.

Note: The indoor unit must be installed more than 2.3m above the floor for the best

efficiency.

Install the piping hole

Drill hole with 65mm core drill.

Insert the through wall pipe into the hole

Note: Drill the hole from indoors to outdoors with a 5° downward inclination.

Indoor unit installation preparation

Install the drain hose

Run the drain hose sloping downward. 
Do not install the drain hose as illustrated 

(see figure 7)

.

When connecting extension drain hose insulate the connecting part of
extension drain hose with a shield material.

Indoor unit electrical wiring

The indoor unit electrical wiring is already connected to the indoor unit
during manufacture.

If the wiring or any other part is damaged, please contact Addvent on 
0117 923 5375.

Wrap the pipe and wiring.

Hold down the end of the pipe, pull it out, form the extension part.

Wrap the piping and wiring and pull them through the cut-off-tailings hole.

When routing the pipe and wire from the left or right side of the indoor
unit, cut off the tails from the pipe holder if necessary.

NOTE:  EMC Directive 89/336/EEC to prevent flicker impressions during the start of

the compressor (technical process) and the adverse influence caused by the
second harmonics of the compressor, the following installation conditions apply.

The power connection for the air conditioner has to be done at the main power
distribution. The distribution has to be of a low impedance, normally the required
impedance reaches at a 32A fusing point.

2

No other equipment has to be connected with this power line.

3

For detailed installation acceptance, please refer to your contractor with the power
supplier if restrictions do apply for products like washing machines, air conditioner
or electrical ovens.

4

For power details of the air conditioner, refer to the rating plate of the product.

5

For any further questions contact Addvent on 0117 923 5375.

5

Figure 6

Figure 7

Figure 8

AV18Ninstructions  12/3/08  09:06  Page 5

Содержание AVACSPL12N

Страница 1: ...ion Instructions and User Guide IMPORTANT SAFEGUARDS WHEN USING ANY ELECTRICAL APPLIANCE BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED PLEASE READ ALL INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE...

Страница 2: ...ed and Air Flow Adjustment 13 Sleep Mode 14 Sweep Operation 13 Timer Operation ON OFF Timer 14 Tips for Operation 15 Maintenance and cleaning 15 Specification 16 2 Figure 2 FEATURES Figure 1 Figure 3...

Страница 3: ...eds to be installed please contact a suitable electrical contractor for this Ensure that the condensation drain is unobstructed DON Ts DO NOT install this appliance on your own This appliance needs to...

Страница 4: ...it and where the outdoor unit can be held in the horizontal position in a place where the operational noise and discharged air does not disturb others in a place free of a leakage of combustible gas w...

Страница 5: ...on 0117 923 5375 Wrap the pipe and wiring Hold down the end of the pipe pull it out form the extension part Wrap the piping and wiring and pull them through the cut off tailings hole When routing the...

Страница 6: ...8 9 10 10 3 4 5 Take off the plastic nuts at the outdoor unit and connection pipe quick couplings Align the centre of the outdoor unit quick coupling and screw the quick coupling pipe by hand Do not u...

Страница 7: ...15 16 17 Before connecting the electric wiring at the outdoor unit make sure the power of indoor unit is unplugged Remove the cable clamp Connect the electric wiring to outdoor unit with the wiring c...

Страница 8: ...on time off time and on off time within a 24 hour period Auto Air Speed Adjustment Auto setting high medium and low air speeds as per difference between set temperature and room temperature Sweep Fun...

Страница 9: ...it is running the LED display will show running status When LED display is OFF a symbol is shown on the remote controller When the LED display is turned OFF you can still control all functions The tim...

Страница 10: ...sec Of temperature setting Number LED stop flashing and then indicates room temperature Fan speed setting When high speed is selected the Fan speed LED flashes quickly Time setting When the timer mode...

Страница 11: ...carefully When mounting on the wall Select a place where indoor unit can receive remote control signal and fix the holder Remote Control cannot be used emergency operation In case the batteries in th...

Страница 12: ...unit Operating modes When started operation mode will turn into cooling or dehumidifying or heating as per room temperature lf operation stops for two hours it restarts in the same set mode as before...

Страница 13: ...uto Select high mode to cool entire room Select sleep operation to reduce the noise levels when you want to sleep Press to change up down air direction Every time the button is pressed air direction c...

Страница 14: ...ges by 10 To release this operation Press to release timer Timer OFF setting operation Press during operation to set of timer OFF Every time this button is pressed it changes in sequence of timer OFF...

Страница 15: ...ge Note Turn off the system unplug mains and turn off breaker before cleaning high speed turning fan during operation may cause injury 15 Tips for operation Cooling How to make cooling more efficient...

Страница 16: ...2 000 18 000 Rated input kW 3 5 5 1 Heating Capacity btu h 13 500 19 000 kW 4 0 5 6 EER kW 3 21 2 83 Energy Class A C COP kW 3 67 3 22 Energy Class A C Refrigerant charge 5m kG 1 00 1 45 Water proof c...

Отзывы: