Specifications

AVACSPL12N

AVACSPL18N

Power supply

220-240V/50Hz

220-240V/50Hz

Cooling capacity

kW

12,000

18,000

Rated input  

kW

3.5

5.1

Heating Capacity

btu/h

13,500

19,000

kW

4.0

5.6

EER

kW 3.21 2.83 

Energy Class

A

C

COP

kW 3.67 3.22 

Energy Class

A

C

Refrigerant charge (5m)

kG

1.00

1.45

Water proof class 

outdoor unit

IP24

Dehumidification

L/h

1.3

2.0

Power Input

Cooling  

W

1,090

1,800

Heating  

W

1,090

1,740

Airflow

H m

3

/h

520

800

M

450

700

L

380

600

Noise Level @ 1m

H

dB(A)

40

43

M

36

39

L

32

35

Dimensions 

indoor unit  HxWxD 

mm

275x790x200

275x930x200

outdoor unit  HxWxD 

mm

545x830x255

545x830x255

Net weight 

indoor unit 

kG

10

12

outdoor unit

kG

34

40

IP

24

AV18Ninstructions  12/3/08  09:06  Page 1

Содержание AVACSPL12N

Страница 1: ...ion Instructions and User Guide IMPORTANT SAFEGUARDS WHEN USING ANY ELECTRICAL APPLIANCE BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED PLEASE READ ALL INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE...

Страница 2: ...ed and Air Flow Adjustment 13 Sleep Mode 14 Sweep Operation 13 Timer Operation ON OFF Timer 14 Tips for Operation 15 Maintenance and cleaning 15 Specification 16 2 Figure 2 FEATURES Figure 1 Figure 3...

Страница 3: ...eds to be installed please contact a suitable electrical contractor for this Ensure that the condensation drain is unobstructed DON Ts DO NOT install this appliance on your own This appliance needs to...

Страница 4: ...it and where the outdoor unit can be held in the horizontal position in a place where the operational noise and discharged air does not disturb others in a place free of a leakage of combustible gas w...

Страница 5: ...on 0117 923 5375 Wrap the pipe and wiring Hold down the end of the pipe pull it out form the extension part Wrap the piping and wiring and pull them through the cut off tailings hole When routing the...

Страница 6: ...8 9 10 10 3 4 5 Take off the plastic nuts at the outdoor unit and connection pipe quick couplings Align the centre of the outdoor unit quick coupling and screw the quick coupling pipe by hand Do not u...

Страница 7: ...15 16 17 Before connecting the electric wiring at the outdoor unit make sure the power of indoor unit is unplugged Remove the cable clamp Connect the electric wiring to outdoor unit with the wiring c...

Страница 8: ...on time off time and on off time within a 24 hour period Auto Air Speed Adjustment Auto setting high medium and low air speeds as per difference between set temperature and room temperature Sweep Fun...

Страница 9: ...it is running the LED display will show running status When LED display is OFF a symbol is shown on the remote controller When the LED display is turned OFF you can still control all functions The tim...

Страница 10: ...sec Of temperature setting Number LED stop flashing and then indicates room temperature Fan speed setting When high speed is selected the Fan speed LED flashes quickly Time setting When the timer mode...

Страница 11: ...carefully When mounting on the wall Select a place where indoor unit can receive remote control signal and fix the holder Remote Control cannot be used emergency operation In case the batteries in th...

Страница 12: ...unit Operating modes When started operation mode will turn into cooling or dehumidifying or heating as per room temperature lf operation stops for two hours it restarts in the same set mode as before...

Страница 13: ...uto Select high mode to cool entire room Select sleep operation to reduce the noise levels when you want to sleep Press to change up down air direction Every time the button is pressed air direction c...

Страница 14: ...ges by 10 To release this operation Press to release timer Timer OFF setting operation Press during operation to set of timer OFF Every time this button is pressed it changes in sequence of timer OFF...

Страница 15: ...ge Note Turn off the system unplug mains and turn off breaker before cleaning high speed turning fan during operation may cause injury 15 Tips for operation Cooling How to make cooling more efficient...

Страница 16: ...2 000 18 000 Rated input kW 3 5 5 1 Heating Capacity btu h 13 500 19 000 kW 4 0 5 6 EER kW 3 21 2 83 Energy Class A C COP kW 3 67 3 22 Energy Class A C Refrigerant charge 5m kG 1 00 1 45 Water proof c...

Отзывы: