5.

 

Before You Start 

Monitoring Centre (ARC) 

Make sure that the monitoring centre to which the IRIS Touch device will send alarm signals is equipped 
with the appropriate IRIS Secure Apps receiving system. The following information should be obtained 
from the monitoring centre. 

Dialler account number    

Monitoring centre IP address    

 

Ethernet Connection Details 

The customer’s Ethernet (LAN) network details are required in order to connect the IRIS Touch. The 
following information should be obtained from the customer.  

Fixed IP address or DHCP 

 

 

If using DHCP then the following information will not be 

required as will be assigned by the network. 

IP address    

Gateway address 

 

Subnet mask address 

 

 

GPRS SIM Card and Access Point Name 

If the installation uses GPRS then a SIM card will be required. The IRIS Touch will also need to be given a 
GPRS ‘Access Point Name’ (APN) and other possible configurations as shown below. These can be obtained 
from the SIM card provider.  

Access Point Name (APN) 

 

User Name (USR) 

 

Password (PWD) 

 

SIM Pin 

 

Содержание Iris Touch 2 Series

Страница 1: ...IRIS Touch Quick Installation Maintenance Guide Version 1 0...

Страница 2: ...Page 2 of 16 IRIS Touch Quick Installation Maintenance Guide Version 1 0...

Страница 3: ...ouch 7 Mounting 7 6 1 Power 7 6 2 Connections 7 6 3 GSM SIM card IRIS Touch 200 240 8 6 4 Dial Capture 8 6 5 PIN Inputs 8 6 6 Switch on and test 8 6 7 Configuration 9 6 8 Panel Configuration 10 6 9 Te...

Страница 4: ...or configuration local alerts and allows diagnostic and tests to be performed by the engineer Polling and alarm over communication paths of Ethernet and or GPRS 3G 4G and CDMA on request to the monito...

Страница 5: ...Yellow flashing Not currently configured or indicating that there are some current faults outstanding Yellow constant Communicating and no current faults flickers on every poll Micro USB Front tamper...

Страница 6: ...Ethernet LAN network details are required in order to connect the IRIS Touch The following information should be obtained from the customer Fixed IP address or DHCP If using DHCP then the following i...

Страница 7: ...TO THE DIALLER UNTIL INDICATED Connections 6 3 Connect cables to the PCB for your system as shown on in Section 4 Board Configuration Ethernet enabled systems IRIS Touch 220 240 Ethernet socket ETH1...

Страница 8: ...ges over IP to the monitoring centre Note These pin alarm inputs can also be used when the dialler is directly connected to an alarm panel via the serial or RS485 connections Via Open Close Contact So...

Страница 9: ...croll bar on right till you see option for Default All 3 Enter the Default All and confirm the default this will cause the dialler to reboot and will now be defaulted Configuration via touch screen IR...

Страница 10: ...toring centre IP address e g 192 168 0 34 would become 192168000034 Acoount Number 4 6 digit account number allocated by the monitoring centre Note If the Alarm Override mode is selected the IRIS Touc...

Страница 11: ...and can perform the following checks Confirm current status 7 1 The IRIS Touch will indicate Status ok If the current dialler setup is all working correctly and if the status is showing Status Troubl...

Страница 12: ...his will test all configured communication paths Please refer to the IRIS Touch Engineer Manual for more details available from http www chironsc com downloads_security html Test alarm panel alarms an...

Страница 13: ...rface to alarm panel RS485 RS232 TTL RS232 PIN Inputs interface to alarm panel Maximum input voltage range 0V to 24V Input low alarm threshold 1V Input high restore threshold 2V Internal pull up imped...

Страница 14: ...s Dial capture interface SELV suitable for connection to the TNV interface of single line telecommunications equipment such as telephones fax machines etc Power Interface SELV for connection to a DC s...

Страница 15: ...IRIS Touch Quick Installation Maintenance Guide Version 1 0 Page 15 of 16...

Страница 16: ...quiries 41 435 080 870 Email sales chironsc com www chironsc com CHIRON SECURITY COMMUNICATIONS AG BAARERSTRASSE 19 6300 ZUG SWITZERLAND The information contained is supplied without liability for any...

Отзывы: