Introduction 

The IRIS Touch 

 offers cost effective Alarm over IP (AoIP) for the commercial and residential sectors. 

All IRIS Touch 

 diallers are certified as suitable for all Grade 4 systems with an Alarm Transmission 

System (ATS) configuration SP6 for single path, or ATS configuration DP4 for dual path (IRIS Touch 240 
only). 

The IRIS Touch 

 is based on Chiron’s successful IRIS Touch range of AoIP diallers with the same 

hardware and software used in all IRIS diallers; with the same level of security and features provided to 
military, governments, banks and commercial industry markets. 

The IRIS Touch 

 offers a touch screen as standard for configuration, local alerts, and allows diagnostic 

and tests to be performed by the engineer. Polling and alarm over communication paths of Ethernet and or 
GPRS (3G, 4G and CDMA on request) to the monitoring centre.  

This manual describes a quick guide to the installation of products from the IRIS Touch 

. For the full 

manual, including multi-lingual versions, please visit our website at: 

http://www.chironsc.com/downloads_security.html

 

2.

 

Product Features 

Features 

IRIS Touch 

200 

220 

240 

Fire retardant enclosure 







Touch screen 







Ethernet 

̶̶ 

GPRS 



̶̶



Dial capture 

 





Relays 

Inputs (Pins)  

Serial RS485 

 

 

 

Serial TTL 

 

 

 

RS232 (Basic or Full) 

Basic 

Text messaging 



̶̶



Multi language menus 







VoIP & SIP services 







Option available on request 

3G / 4G /  CDMA 

3.

 

Package Contents 

Contents dependent on model type: 

 

Dialler board in plastic housing 

 

Ethernet cable (IRIS Touch 220 & 240) 

 

GSM antenna (IRIS Touch 200 & 240) 

 

Stylus 

 

18k Ohms sense resistor 

Содержание Iris Touch 2 Series

Страница 1: ...IRIS Touch Quick Installation Maintenance Guide Version 1 0...

Страница 2: ...Page 2 of 16 IRIS Touch Quick Installation Maintenance Guide Version 1 0...

Страница 3: ...ouch 7 Mounting 7 6 1 Power 7 6 2 Connections 7 6 3 GSM SIM card IRIS Touch 200 240 8 6 4 Dial Capture 8 6 5 PIN Inputs 8 6 6 Switch on and test 8 6 7 Configuration 9 6 8 Panel Configuration 10 6 9 Te...

Страница 4: ...or configuration local alerts and allows diagnostic and tests to be performed by the engineer Polling and alarm over communication paths of Ethernet and or GPRS 3G 4G and CDMA on request to the monito...

Страница 5: ...Yellow flashing Not currently configured or indicating that there are some current faults outstanding Yellow constant Communicating and no current faults flickers on every poll Micro USB Front tamper...

Страница 6: ...Ethernet LAN network details are required in order to connect the IRIS Touch The following information should be obtained from the customer Fixed IP address or DHCP If using DHCP then the following i...

Страница 7: ...TO THE DIALLER UNTIL INDICATED Connections 6 3 Connect cables to the PCB for your system as shown on in Section 4 Board Configuration Ethernet enabled systems IRIS Touch 220 240 Ethernet socket ETH1...

Страница 8: ...ges over IP to the monitoring centre Note These pin alarm inputs can also be used when the dialler is directly connected to an alarm panel via the serial or RS485 connections Via Open Close Contact So...

Страница 9: ...croll bar on right till you see option for Default All 3 Enter the Default All and confirm the default this will cause the dialler to reboot and will now be defaulted Configuration via touch screen IR...

Страница 10: ...toring centre IP address e g 192 168 0 34 would become 192168000034 Acoount Number 4 6 digit account number allocated by the monitoring centre Note If the Alarm Override mode is selected the IRIS Touc...

Страница 11: ...and can perform the following checks Confirm current status 7 1 The IRIS Touch will indicate Status ok If the current dialler setup is all working correctly and if the status is showing Status Troubl...

Страница 12: ...his will test all configured communication paths Please refer to the IRIS Touch Engineer Manual for more details available from http www chironsc com downloads_security html Test alarm panel alarms an...

Страница 13: ...rface to alarm panel RS485 RS232 TTL RS232 PIN Inputs interface to alarm panel Maximum input voltage range 0V to 24V Input low alarm threshold 1V Input high restore threshold 2V Internal pull up imped...

Страница 14: ...s Dial capture interface SELV suitable for connection to the TNV interface of single line telecommunications equipment such as telephones fax machines etc Power Interface SELV for connection to a DC s...

Страница 15: ...IRIS Touch Quick Installation Maintenance Guide Version 1 0 Page 15 of 16...

Страница 16: ...quiries 41 435 080 870 Email sales chironsc com www chironsc com CHIRON SECURITY COMMUNICATIONS AG BAARERSTRASSE 19 6300 ZUG SWITZERLAND The information contained is supplied without liability for any...

Отзывы: