background image

Addi-dAtA GmbH · Airpark Business Center · Airport Boulevard B210 · 77836 Rheinmünster · Germany

tel: +49 7229 1847-0 · Fax: +49 7229 1847-200 · info

@

addi-data.com · www.addi-data.com 

02.04 - 08/2014

QUICK 

INSTALLATION

MSX-E3701 and MSX-E3700 

Ethernet system for length measurement

Содержание MSX-E3701

Страница 1: ...s Center Airport Boulevard B210 77836 Rheinmünster Germany Tel 49 7229 1847 0 Fax 49 7229 1847 200 info addi data com www addi data com 02 04 08 2014 QUICK INSTALLATION MSX E3701 and MSX E3700 Ethernet system for length measurement ...

Страница 2: ...he Ethernet system D Connect the Ethernet system to the power source using a power supply cable e g CMX 20 E Check the status of the Ethernet system by means of the LED display Power On lights green Power supply is OK Port 0 ACT Link flashes yellow Ethernet cable is connected to Port 0 Port 1 ACT Link flashes yellow Ethernet cable is connected to Port 1 Status lights green Ethernet system is ready...

Страница 3: ...ow 2 RD0 RD1 white 3 TD0 TD1 orange 4 RD0 RD1 blue Trigger Synchro Trigger Sync In Trigger Sync Out Cable purple Pin No Connector 5 pin M12 Female connector 5 pin M12 Lead colour Lead pair 1 Trigger input Trigger input blue 1 2 Trigger input Trigger input white 3 Synchro input Synchro output red 2 4 Synchro input Synchro output black 5 Ground Ground Pin assignment ...

Страница 4: ...V 24 V white 3 Ground Ground blue 4 Ground Ground black 5 not connected not connected grey MSX E3700 Ethernet Ethernet Port 0 Ethernet Port 1 Pin No RJ45 connector Pin No RJ45 connector 1 TD0 9 TD1 2 TD0 10 TD1 3 RD0 11 RD1 4 not connected 12 not connected 5 not connected 13 not connected 6 RD0 14 RD1 7 not connected 15 not connected 8 not connected 16 not connected ...

Страница 5: ...1 mm grid 3 pin terminal 3 81 mm grid Note 1 Trigger input Synchro In Twisted pair 2 Trigger input Synchro Out 3 Ground Ground Power supply Power Supply In Power Supply Out Pin No 3 pin terminal 5 08 mm grid 3 pin terminal 5 08 mm grid 1 24 V 24 V 2 Ground Ground 3 Shield Shield ...

Страница 6: ... red ring is placed on the cable connector in addition to the letter code on the transducer Software tool ConfigTools First steps After connecting the required components to your Ethernet system and checking if the power supply is ensured continue as follows Install the software tool ConfigTools which is to be found on the supplied CD MSX E Systems As soon as you have started the installed softwar...

Страница 7: ...X E system The following actions are possible IP Address Change the IP address of the MSX E system in order to adapt it for example to your corporate network Web Interface Access the web interface of your MSX E system and change the configuration Save General Configuration Save the general configuration of the MSX E system including for example the network configuration i e all the settings define...

Страница 8: ... the channels to be acquired and start the acquisition with monitoring For each channel each acquired value is immediately displayed in a diagram NOTICE Depending on the Ethernet system a different number of buttons and accordingly different types of actions are available Web interface Quick access to the MSX E system From the web interface of your MSX E system you can access the system quickly an...

Отзывы: