ADDER AdderLink X-Series Скачать руководство пользователя страница 16















15













Other products in the X-Series range

The following related X-Series items are also available:

•  

Gold Extender (part code: X-KVMAS)

   This pair of modules allow you to extend not only keyboard, video and 

mouse signals up to 200 metres, but also similarly support microphone, 
stereo speaker and an RS232 serial channel. 

•  

Dual video transmitter (part code: X-DVT)

   Allows one system to be controlled from two locations or permits a second 

video channel to be sent to a remote location. Used in conjunction with two 
standard receiver/remote modules.

•  

Remote receiver module (part code: X-KVM/R)

Two of these are required, one at the end of both remote cable spurs 
emanating from the Dual Video Transmitter. These modules convert the 
coded signals from the Dual Video Transmitter back into native formats used 
by keyboards, video monitors and mice.

•  

Skew compensator (part code: X-SC)

   Removes colour split in video signals caused by certain Cat 5e and 6 cables. 

Required only in certain installations with long cable lengths and high video 
resolutions.

•  

Rack mount chassis (part code: RMK-CHASSIS)

   This 19” chassis allows multiple X-Series modules to be neatly arranged 

within a standard cabinet. Securing plates and screws are supplied separately 
for each X-Series module for use with the rack mount chassis.

•  

Power distribution module (part code: X-PDM4)

   Provides power for up to four X-Series modules to reduce mains power 

socket requirements.

•  

Rack mount securing plates

• for USB Extender (part code: X-RMK-USB)
• for Gold Extender remote module (part code: X-RMK-KVMAS/R)
• for Gold Extender local module (part code: X-RMK-KVMAS/T)
• for Dual Video Transmitter (part code: X-RMK-DVT)
• for Skew compensator (part code: X-RMK-SC)
• single slot blanking plate (part code: X-RMK-BLANK)
• quad slot blanking plate (part code: X-RMK-BLANK4)

Safety information

•  For use in dry, oil free indoor environments only.
•  Do not use to link between buildings.
•  Ensure that the twisted pair interconnect cable is installed in compliance 

with all applicable wiring regulations. 

•  Do not connect the CATx link interface (RJ45 style connector) to any other 

equipment, particularly network or telecommunications equipment.

•  Warning – the power adapter contains live parts.
•  No user serviceable parts are contained within the power adapter - do not 

dismantle.

•  Plug the power adapter into a socket outlet close to the AdderLink unit that 

it is powering.

•  Replace the power adapter with a manufacturer approved type only. 
•  Do not use the power adapter if the power adapter case becomes damaged, 

cracked or broken or if you suspect that it is not operating properly.

•  If you use a power extension cord with the AdderLink, make sure the total 

ampere rating of the devices plugged into the extension cord do not exceed 
the cord’s ampere rating. Also, make sure that the total ampere rating of all 
the devices plugged into the wall outlet does not exceed the wall outlet’s 
ampere rating.

•  Do not attempt to service the AdderLink yourself.
•  The AdderLink units and power supplies can get warm in operation – do not 

situate them in an enclosed space without any ventilation. 

•  The AdderLink does not provide ground isolation and should not be used for 

any applications that require ground isolation or galvanic isolation.

Warranty

Adder Technology Ltd warrants that this product shall be free from defects in 
workmanship and materials for a period of two years from the date of original 
purchase. If the product should fail to operate correctly in normal use during the 
warranty period, Adder will replace or repair it free of charge. No liability can be 
accepted for damage due to misuse or circumstances outside Adder’s control. 
Also Adder will not be responsible for any loss, damage or injury arising directly 
or indirectly from the use of this product. Adder’s total liability under the terms 
of this warranty shall in all circumstances be limited to the replacement value 
of this product. If any difficulty is experienced in the installation or use of this 
product that you are unable to resolve, please contact your supplier.

Содержание AdderLink X-Series

Страница 1: ...AdderLink X Series USB Extender www adder com SERIES LOCAL POW ER ON HOST LIN K AUDIO T O R E M O T E USB VID EO ADDER...

Страница 2: ...REMOTE module 8 Video monitor 8 USB devices including keyboard mouse 8 Audio connections 9 Link connection s 9 Power supply 10 Operation General use 11 Power surge fuses 11 Power and activity indicato...

Страница 3: ...ated next to the user and attaches to the various peripherals The two modules are then linked by one or two standard CAT 5 twisted pair cables one to carry video and USB data the other to optionally t...

Страница 4: ...nection to PC video output Connection to PC USB port Connection to PC microphone and speaker ports Connection to video monitor Four USB v1 1 ports Connections for microphone and speakers Option switch...

Страница 5: ...lable as a separate kit onto the front of the module and secure it with the two countersunk screws 2 Orient the module on its side so that its labelled face is the correct way up and the securing plat...

Страница 6: ...at the PC system is switched off when connecting cables LOCAL Module connects to the PC REMOTE Module connects to the peripherals by the user 2 Attach the other end of the video cable to the video out...

Страница 7: ...nit the REMOTE module however always requires a power supply Audio 1 Locate the supplied audio cable and attach one end to the required jack socket marked speaker or microphone on the LOCAL module if...

Страница 8: ...ne and or speakers 1 Insert the connector from the secondary twisted pair cable link into the LOCAL module socket marked AUDIO Video and USB link cable 1 Insert the connector from the primary twisted...

Страница 9: ...Audio microphone and speakers Link connection s Power supply Cables can be attached in any order not necessarily the order shown in this section Video monitor 1 Attach the lead from the monitor to th...

Страница 10: ...The REMOTE module provides a signal boost feature to assist with unresponsive microphones See Microphone signal boost for details Link connection s Links between the REMOTE and LOCAL modules are made...

Страница 11: ...odule 1 Attach the output connector of the power supply to the REMOTE module socket marked POWER 2 Insert the IEC connector of the supplied power lead into the corresponding socket of the power supply...

Страница 12: ...nk intact then the anti surge surge fuse may have been tripped Reset the anti surge fuse as detailed next To reset an anti surge fuse Remove the power connection or for an unpowered LOCAL module the U...

Страница 13: ...X Series USB extender modules feature both video and microphone signal loss compensation features Video signal boost Two separate boost features are available to ensure that the video signal remains...

Страница 14: ...es USB extenders however less responsive microphones may require an extra boost This feature boosts the microphone signal by roughly ten times Microphone signal boost Switch 1 Disabled OFF Enabled ON...

Страница 15: ...ired correctly See the Connections section for details If possible try using an alternative USB VIDEO link cable between the modules Temporarily disconnect the video link to the LOCAL module connect a...

Страница 16: ...pair interconnect cable is installed in compliance with all applicable wiring regulations Do not connect the CATx link interface RJ45 style connector to any other equipment particularly network or tel...

Страница 17: ...en the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the supplier or an experienced radio TV technician...

Страница 18: ...No ADD0055 Adder Technology Limited Technology House Trafalgar Way Bar Hill Cambridge CB3 8SQ United Kingdom Tel 44 0 1954 780044 Fax 44 0 1954 780081 Adder Corporation 29 Water Street Newburyport MA...

Отзывы: