ADDER AdderLink X-Series Скачать руководство пользователя страница 12















11













Operation

General use

In use, the USB Extender modules should be transparent - the system and its 
peripherals should operate exactly as normal, the only difference being that they 
are now up to 100 metres apart. 
In some installations, you may see some ‘shadows’ to the right of high contrast 
screen characters. This can be caused by signal loss over long distances (or low 
quality link cables) or by incorrect video signal compensation settings - see the 

Signal loss compensation

 section for details. 

Power surge fuses

Both modules contain internal automatic cut-out fuses to protect against power 
surges. 

If a module stops responding

•  Check whether the module’s ON indicator is lit. If the ON indicator is lit, then 

the problem is unlikely to be power related, check all the connections.

•  If the module ON indicator is not lit, check the indicator on its power supply, 

or for the LOCAL module, check that the PC is operating and the USB link is 
still connected.

•  If the power supply indicator is lit, or the PC is operating (with the USB link 

intact), then the anti-surge surge fuse may have been tripped. Reset the 
anti-surge fuse, as detailed next.    

To reset an anti-surge fuse

Remove the power connection (or, for an unpowered LOCAL module, the USB 
connection) from the module for one second and then reconnect. 

PO

W

ER

ON

HO

ST

LIN

K

AUDI

O

T

O REMO

TE

USB+

VIDEO

ER

®

PO

WER

ON

COMPENSA

TION

LINK

AUDI

O

T

O LOCAL

USB+

VIDEO

ER

®

ON

Lit whenever power (from the PC USB 
port or optional power supply) is present.

HOST

Lit whenever a USB host (PC) is connected 
and at least one device is attached at the 
REMOTE module. This indicator will flicker 
when an active PC host is connected, 
but will darken if there is no remote USB 
device.

LINK

Lit when a physical link exists between the 
LOCAL and REMOTE modules.

ON

Lit whenever power from the power 
supply is present.

LINK

Lit whenever a USB host (PC) is connected 
at the LOCAL module and at least one 
device is attached at the REMOTE module. 
This indicator will flicker when an active 
PC host is connected, but will darken if 
there is no USB device connected at the 
REMOTE module.

Power and activity indicators

The front panels of both modules feature recessed indicators to provide 
confirmation of power and activity.

LOCAL module

REMOTE module

SECT 4

Содержание AdderLink X-Series

Страница 1: ...AdderLink X Series USB Extender www adder com SERIES LOCAL POW ER ON HOST LIN K AUDIO T O R E M O T E USB VID EO ADDER...

Страница 2: ...REMOTE module 8 Video monitor 8 USB devices including keyboard mouse 8 Audio connections 9 Link connection s 9 Power supply 10 Operation General use 11 Power surge fuses 11 Power and activity indicato...

Страница 3: ...ated next to the user and attaches to the various peripherals The two modules are then linked by one or two standard CAT 5 twisted pair cables one to carry video and USB data the other to optionally t...

Страница 4: ...nection to PC video output Connection to PC USB port Connection to PC microphone and speaker ports Connection to video monitor Four USB v1 1 ports Connections for microphone and speakers Option switch...

Страница 5: ...lable as a separate kit onto the front of the module and secure it with the two countersunk screws 2 Orient the module on its side so that its labelled face is the correct way up and the securing plat...

Страница 6: ...at the PC system is switched off when connecting cables LOCAL Module connects to the PC REMOTE Module connects to the peripherals by the user 2 Attach the other end of the video cable to the video out...

Страница 7: ...nit the REMOTE module however always requires a power supply Audio 1 Locate the supplied audio cable and attach one end to the required jack socket marked speaker or microphone on the LOCAL module if...

Страница 8: ...ne and or speakers 1 Insert the connector from the secondary twisted pair cable link into the LOCAL module socket marked AUDIO Video and USB link cable 1 Insert the connector from the primary twisted...

Страница 9: ...Audio microphone and speakers Link connection s Power supply Cables can be attached in any order not necessarily the order shown in this section Video monitor 1 Attach the lead from the monitor to th...

Страница 10: ...The REMOTE module provides a signal boost feature to assist with unresponsive microphones See Microphone signal boost for details Link connection s Links between the REMOTE and LOCAL modules are made...

Страница 11: ...odule 1 Attach the output connector of the power supply to the REMOTE module socket marked POWER 2 Insert the IEC connector of the supplied power lead into the corresponding socket of the power supply...

Страница 12: ...nk intact then the anti surge surge fuse may have been tripped Reset the anti surge fuse as detailed next To reset an anti surge fuse Remove the power connection or for an unpowered LOCAL module the U...

Страница 13: ...X Series USB extender modules feature both video and microphone signal loss compensation features Video signal boost Two separate boost features are available to ensure that the video signal remains...

Страница 14: ...es USB extenders however less responsive microphones may require an extra boost This feature boosts the microphone signal by roughly ten times Microphone signal boost Switch 1 Disabled OFF Enabled ON...

Страница 15: ...ired correctly See the Connections section for details If possible try using an alternative USB VIDEO link cable between the modules Temporarily disconnect the video link to the LOCAL module connect a...

Страница 16: ...pair interconnect cable is installed in compliance with all applicable wiring regulations Do not connect the CATx link interface RJ45 style connector to any other equipment particularly network or tel...

Страница 17: ...en the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the supplier or an experienced radio TV technician...

Страница 18: ...No ADD0055 Adder Technology Limited Technology House Trafalgar Way Bar Hill Cambridge CB3 8SQ United Kingdom Tel 44 0 1954 780044 Fax 44 0 1954 780081 Adder Corporation 29 Water Street Newburyport MA...

Отзывы: