Introduction

Welcome

Thank you for choosing AdderLink Infinity, otherwise known as ALIF or ALIF1000. ALIF 
represents a major advance in the capabilities of digital extenders and switches. By 
encoding high quality DVI video, digital audio and USB connections into Internet Protocol 
(IP) messages, ALIF offers highly advanced and flexible signal switching capabilities.
Adder’s extensive knowledge of interfacing techniques and high speed networking 
has allowed us to develop new ways to break the chains of local DVI, USB and 
audio connections. With ALIF, distance is finally no barrier to high specification, high 
performance computing. Furthermore, since all signals are now IP, the most elaborate 
and yet simple-to-use switching and multicast techniques make possible a great variety of 
uses.
The TX transmitter attaches to a single computer while the RX receiver connects with 
your DVI video monitor, microphone, speakers and up to four USB peripherals. The 
distance between them is limited only by the size of your network. 
In addition to separating one computer and its peripherals, ALIF promotes sharing. 
You can arrange for a limitless number of screens and speakers, distributed anywhere 

across the network, to receive video and audio. You can also switch between any number 
of transmitter units from a single screen, keyboard and mouse in order to monitor a 
potentially vast collection of remote systems.
All units feature browser-based configuration utilities to allow quick and easy set up, 
from near or far. 

one-to-one 

configuration

The simplest configuration links one RX unit to a single TX unit, either by a 

direct link or over much greater distances via a Gigabit Ethernet network.

ALIF and A.I.M.

Where multiple ALIF units are used on a network, we have developed the AdderLink 
Infinity Management (A.I.M.) server to allow comprehensive and secure central 
control of all transmitters, receivers and users.
When using an A.I.M. server to configure ALIF 
units, it is vital that all ALIF units that you wish 
to locate and control are set to their factory 
default settings. Otherwise they will not be 
located by the A.I.M. server. If necessary, 
perform a 

factory reset

 on each ALIF unit.

Please also see 

Appendix C - Tips for success when networking ALIF units

     

www.adder.com

AdderLink

ADM

ADM

USR

USR

UNC

UNC

ETH1

ETH1

ETH2

ETH2

PWR

PWR

MANAGEMENT SERVER

One-to-many configuration

Using multicast techniques, an unlimited number 
of receivers* can receive video and audio data 
streams from a single TX unit.   

* A maximum of thirteen concurrent USB inputs (via 
multiple RX units) are permitted to a single TX unit.

Mixing ALIF and ALIF dual units

AdderLink Infinity dual (2000 series) units offer additional abilities of dual DVI video 
channels plus the option of fibre optic linking. They are complimentary to the standard 
(1000 series) models and it is possible to mix ALIF and ALIF dual transmitters and 
receivers on a network. However, whenever the two types are cross connected, the 
extra abilities of the ALIF dual units will be temporarily disabled.

Содержание AdderLink Infinirt

Страница 1: ...AdderLink Infinity User Guide Experts in Connectivity Solutions KVM Extension Solutions...

Страница 2: ...erLink Infinity browser based configuration utility 16 A rough guide to configuring TX and RX units 17 TX transmitter unit configuration 17 RX receiver unit configuration 18 Performing an upgrade 20 O...

Страница 3: ...of remote systems All units feature browser based configuration utilities to allow quick and easy set up from near or far One to one configuration The simplest configuration links one RX unit to a si...

Страница 4: ...etails INDOOR USE ONLY OPTIONS AUX LINE IN LINE OUT DVI D 1 2 USER CONSOLE 5V 2 5A ON 2 1 MIC IN Video output Audio line in out AUX serial port USB ports Power input System Gigabit Ethernet port Syste...

Страница 5: ...Power adapter 12 5W and country specific power cord Supplied items 2 x Audio cable 2m 3 5mm stereo jacks Serial null modem cable 2m ALIF transmitter 1000T package ALIF1000R unit Power adapter 12 5W an...

Страница 6: ...t brackets and four screws Part numbers One unit per 1U rack slot RMK4S Two units per 1U rack slot RMK4D Single link DVI D to DVI D video cable Part number VSCD1 Power adapter 12 5W and country specif...

Страница 7: ...ck brackets Connections Rack brackets The optional brackets plus four screws allow the units to be secured within a standard rack slot Note The ALIF units and their power supplies generate heat when i...

Страница 8: ...rals Click a connection to see details IMPORTANT When using an AdderLink Infinity Management box to configure ALIF units it is vital that all ALIF units that you wish to locate and control are set to...

Страница 9: ...lug at the other end of the cable to the corresponding DVI D video output socket of the host computer DVI D link from host computer TX audio links ALIF units support two way stereo digital sound so th...

Страница 10: ...extension of RS232 signals up to a baud rate of 115200 The port has software flow control but no hardware flow control AUX USB link from host computer Serial null modem link from your computer To conn...

Страница 11: ...t Note Both the unit and its power supply generate heat when in operation and will become warm to the touch Do not enclose them or place them in locations where air cannot circulate to cool the equipm...

Страница 12: ...network interfaces so for direct point to point connections no crossover Ethernet cable is required To link ALIF units using the System port 1 Connect a CAT 5 5e 6 or 7 cable to the System port socke...

Страница 13: ...rom audio device Link out to speakers 3 Once the unit has been fully connected and powered on access the RX System Configuration page to check that the Audio InputType setting matches the connection t...

Страница 14: ...for pin out between the AUX port on the right hand side of the ALIF rear panel and your remote serial device Supported USB Devices The transmitter unit use True Emulation technology to emulate the sig...

Страница 15: ...t Note Both the unit and its power supply generate heat when in operation and will become warm to the touch Do not enclose them or place them in locations where air cannot circulate to cool the equipm...

Страница 16: ...nfigure control and coordinate any number of ALIF transmitters and receivers from a single application IMPORTANT When using A I M to configure ALIF units it is vital that all ALIF units that you wish...

Страница 17: ...puter to the same network Note A Gigabit connection is not essential for configuration purposes 4 If not already switched on power up your computer and the ALIF unit You are now ready to use the brows...

Страница 18: ...led ticked or disabled unticked as appropriate There are similar options within the RX unit configuration and it is important that the settings in both units are the same If one of these options is ti...

Страница 19: ...try is only necessary when the TX unit is located on a separate network to the RX unit 3 Check that the data streams EnableVideo Enable Audio and Enable USB plus Enable Serial if used are enabled tick...

Страница 20: ...USB and serial addresses The default setting for all four entries is the standard IP address that is factory set within everyTX unit 169 254 1 33 Optionally alter the target IP addresses for each data...

Страница 21: ...cate the downloaded upgrade file check that the file is correct for the unit being upgraded 5 Click the Upgrade Now button A progress bar will be displayed however if your screen is connected to the u...

Страница 22: ...Front panel indicators The six front panel indicators on each unit provide a useful guide to operation Operation Indicators These six indicators clearly show the key aspects of operation NET On when...

Страница 23: ...Warranty Radio frequency energy statements Getting assistance If you are still experiencing problems after checking the information contained within this guide then we provide a number of other soluti...

Страница 24: ...iguration pages This section covers the browser based configuration utility for the AdderLink Infinity TX transmitter unit The TX utility has ten pages titled as follows System Configuration System Me...

Страница 25: ...units may be placed on a different network Enable options These checkboxes allow you to determine which peripheral options will be used Video audio USB and serial Serial port options These allow you t...

Страница 26: ...nsumption at the cost of video color reproduction Options 24 bit 16 bit or 8 bit Use Default DDC and Choose Default DDC When the Use Default DDC option is unticked AdderLink Infinity will use the EDID...

Страница 27: ...Port Range For some devices e g touch screens you may wish to ensure that they are always reported to the same USB port number so that the USB driver will always find the device This option allows yo...

Страница 28: ...ages to a remote server via the network Provide the IP address of a suitable server here also Store system messages in unit When ticked this option will store system messages within the memory of the...

Страница 29: ...n a web browser and enter the IP address of the TX unit Default http 169 254 1 33 If the address is unknown perform a manual factory reset 3 Click either the Statistics Firmware Upgrade or Reboot link...

Страница 30: ...at may be requested by Adder Technical Support To get here 1 If not already connected temporarily connect the AdderLink Infinity unit and a PC via a network 2 Run a web browser and enter the IP addres...

Страница 31: ...unit configuration pages This section covers the browser based configuration utility for the AdderLink Infinity RX receiver unit The RX utility has nine pages titled as follows System Configuration St...

Страница 32: ...or stereo line input mic for mono microphone or mic boost for a mono microphone that requires extra gain 20dB EnableVideo Compatibility Check If enabled this option compares the EDID reported by the P...

Страница 33: ...h When enabled this option will allow for an exchange of control information with an Isochronous device Some devices have multiple endpoints e g a keyboard with an audio controller By enabling this op...

Страница 34: ...b pages with password When ticked this option enables https security so that the configuration pages are only accessible to the admin user with a password To get here 1 If not already connected tempor...

Страница 35: ...ages to a remote server via the network Provide the IP address of a suitable server here also Store system messages in unit When ticked this option will store system messages within the memory of the...

Страница 36: ...n a web browser and enter the IP address of the RX unit Default http 169 254 1 32 If the address is unknown perform a manual factory reset 3 Click either the Statistics Firmware Upgrade or Reboot link...

Страница 37: ...at may be requested by Adder Technical Support To get here 1 If not already connected temporarily connect the AdderLink Infinity unit and a PC via a network 2 Run a web browser and enter the IP addres...

Страница 38: ...and down stream speeds per port Use the same switch make and model throughout a single subnet You also need a Layer 3 switch Ensure that it can operate efficiently as an IGMP Querier Layer 2 and Laye...

Страница 39: ...hes Choose an appropriate forwarding mode on all switches Use Cut through if available otherwise Store and forward Optimize the settings on the ALIF transmitters If color quality is important then lea...

Страница 40: ...are output by an ALIF unit but the network switches have not been configured to use jumbo frames the switches will attempt to break the large packets down into standard packets This process introduces...

Страница 41: ...mputers with DVI video cards Problem The audio output of the ALIF receiver sounds like a scratched re cord This issue is called Audio crackle and is a symptom of the same problem that produces blindin...

Страница 42: ...l hosts report which multicast streams they wish to receive The Querier device and all snooping Layer 2 switches then update their lists accordingly the lists are also updated when Join Group and Leav...

Страница 43: ...Refresh The transmitter sends portions of the video image only when they change In order to give the best user experience the transmitter also sends the whole video image at a lower frame rate in the...

Страница 44: ...d switches latency is rarely an issue Layer 2 and Layer 3 The OSI model When discussing network switches the terms Layer 2 and Layer 3 are very often used These refer to parts of the Open System Inter...

Страница 45: ...Mount kits Rack mount single or dual units per 1U slot VESA monitor wall mount chassis Power to adapter 100 240VAC 50 60Hz 0 5A Power to unit 5VDC 12 5W Operating temp 0 C to 40 C 32 F to 104 F Approv...

Страница 46: ...y is experienced in the installation or use of this product that you are unable to resolve please contact your supplier Safety information For use in dry oil free indoor environments only Warning live...

Страница 47: ...crease the separation between the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the supplier or an exper...

Страница 48: ...ION FURTHER INFORMATION INDEX www ctxd com Documentation by 2013 Adder Technology Limited All trademarks are acknowledged Part No MAN ALIF1000 Release 3 0a Web www adder com Contact www adder com cont...

Страница 49: ...Frame Skipping 25 42 Front panel 3 Front panel indicators 21 I IANA 19 IGMP 41 fast leave 41 querier 41 snooping 41 Indicators 3 21 Initial configuration 15 J Jumbo frames packets 41 L Layers 2 and 3...

Отзывы: