Using
terminal commands
5 for A723
6 for A440
7 for A733 GSM
8 for A731
9 for A732
•
slot
and
samples
are the actual values programmed by using the SLOT
command
•
po
is the power output of the device during the last frame sent; this value is
relative (50 mW corresponds to a value of approx. 25, while 500 mW
corresponds to a value of approx. 200) (this parameter is irrelevant for the
A733GSM/GPRS)
•
err_level
is the error value; 0 means no error
R
EMARKS
GET
only.
R
EMOTE
Yes, GET only. The A733 can issue the command both remotely and locally.
E
XAMPLE
INFO
9193 INFO 255 0 18/4/1999 21:5:11 1.3 0 0 0 91 72 40 1:46 58
65 72 3 900 15 175 0
#
PORT
A
VAILABLE FOR
A731
A733
A732
A733GSM
D
ESCRIPTION
A complex command acting upon the I/O ports of a device.
P
ARAMETERS
A control byte specifying the command, the bit of the port the command is acting
on, and two 16-bit parameters, depending on the control byte; for some
commands, one or both of them may be missing. However, if they are needed for a
certain command but not given, null values are implied.
The control byte’s significance is shown in Fig. 17.
Command Code
Port Number
Fig. 17:
The Control Byte Layout
•
The
Port Number
selects the port that will be affected by the command.
For the A733, only 0000 to 0011 are accepted (only four ports are
available).
•
The
Command Code
specifies the operation that will be applied to the
selected port. They are explained in the table below.
Code Description
Parameters Returns
0000 RDP – Read Data Port. This
command reads the whole 16-bit
port and returns its value; the Port
Number has no significance for this
command.
None
A 16-bit integer and
the result (OK or
ERROR). Only the
lowest four significant
bits reflect valid ports
for the A733.
40