CHAPTER 3
Performing Advanced Functions
38
Command line interpreter
•
1 — command not recognized (=it doesn’t exist or isn’t
supported)
•
2 — command line buffer overflow (input line too long)
•
3 — internal error
•
4 — reserved
•
5 — missing or false parameters in command
•
6 — operation not implemented
•
7 — remote operation not allowed
•
8 — Invalid IMEI checksum number
Device descriptors and storage handler
•
10 — device not found (attempt to perform a command on a
non-existent device)
•
11 — device already exists
•
12 — reserved
•
13 — no more space for descriptors (too many devices)
•
14 — no more records for the specified device
•
15 — temporary communication break, no more data (the last
request was not successful)
•
16 — time-out (the handler blocked or is busy)
•
17 — internal error
•
18 — attempt to insert a reserved device ID number (0 or
65535)
Real time clock
•
20 — incorrect time supplied (conversion to
time_t
was not
possible)
Radio interface
•
30 — error at receive (CRC, etc.)
•
31 — unexpected frame received
•
32 — wrong length
•
33 — reserved
•
34 — reserved
•
35 — time-out (remote device not responding)