![Adcon A725 addSDI Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/adcon/a725-addsdi/a725-addsdi_user-manual_2848442037.webp)
CHAPTER 3
Using terminal commands
35
The date/time specifies the first slot to be retrieved that is strictly
“younger” than the specified time stamp.
R
ETURNS
The data block returned will typically contain a number of data
frames. The structure of a block is as follows:
dd mm yyyy hh mm ss si ft rfin rfout db batt sdih
sdib1 sdib2 ... sdibn cs
where:
•
dd mm yyyy
is the date
•
hh mm ss
is the time
•
si
is the size of the frame (variable for the SDI frames)
•
ft
is the frame type (60)
•
rfin
is the RFin RSSI value
•
rfout
is the RFout RSSI value
•
db
is the digibyte value
•
batt
is the battery voltage value
•
sdih
ist the SDI-12 header
•
sdib1, sdib2 ... sdibn
are the SDI-12 sensor quadruples
•
cs
is a 16-bit checksum obtained by summing the bytes and
discarding the carries over
0xFFFF
(float values are not
included in the checksum).
The composition of the data block of such a frame (the values
marked as sdih, sdib1... sdibn) is depicted in Figure 16.