background image



          

 

       

 

   

  

    ADCA                         

 

VAL

S

TEAM

 

ADCA

                     

We reserve the right to change the design and material of this product without notice.

 

 

IMI PV25G.20 E 04.16 

 
Replacing standard plug: 
 

Separate the actuator from the valve body as described before. In reference to fig.4

 

proceed as follow: 

1.  Loosen the threaded bushing (8) and screw off the lock nuts (10). 
2.  Remove the bonnet (2) from the valve body (1) 
3.  Take off the complete plug stem (6) from the bonnet (2). 
4.  Apply silicon oil on the new complete plug stem and introduce it into the bonnet (3). 
5.  Replace the body gasket (11) after cleaning its housing face carefully. 
6.  Re-assemble all the items in reverse order ensuring the alignment of spindles and plug-seat consequently. 

 
 

 

 

 

Always change the old packing gland when the plug stem replacing is occurred.

 

 

Replacing packings: 
 

Take off the complete plug stem as described on paragraph “REPLACING STANDARD PLUG”

then, in reference 

to the Fig.5, 6 and 7 proceed as follow: 

 

1.  Screw off the threaded bushing (3). 
2.  Remove spring (4) and packing (graphite type G packing do not have spring). 
3.  Clean  the  packing  chamber  accurately  and  apply  silicon  oil  to the  individual  parts  of the  new  packing  and  the 

plug stem. 

4.  Insert the plug stem in the valve bonnet (see note). 
5.  Lodge the new packing and its spring following the right sequence. 
6.  Replace the body gasket (11) (see fig. 4)

 

after cleaning its housing face carefully. 

7.  Re-assemble all the items ensuring the alignment of spindles and plug-seat consequently. 

 
 
 

 

 

 

The valve stem should be correctly fitted within the bonnet before replacing the packing in order to avoid v-rings 
damage.

 

Care should  be taken  when handling  the  gaskets. Some gaskets are stainless steel reinforced and can  easily 
cut.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание ADCATROL PV25

Страница 1: ...allation and maintenance work must be carried out by trained personnel A supervisor must follow and check all activities For the problems that cannot be solve with the help of this instructions please...

Страница 2: ...l responsibility of the contractor Valves are designed to be applied in places protected from exposure to weather We recommend special constructions or protective measures for applications on the outs...

Страница 3: ...turer An ADCA pipeline strainer should be installed upstream of the valve to protect from dirt which could damage the valve or cause mal functioning The strainer must be installed with the sieve sidew...

Страница 4: ...e stem MAINTENANCE We recommend that the control valves to be serviced as necessary Control valves should be checked periodically at least yearly to verify that they are operating correctly When reass...

Страница 5: ...essure until housing is pressure free 5 Check and measure the shifting between yoke base plate 5A and flange valve body 1A and take note 6 Catch the actuator pillars and remove it from valve body Nuts...

Страница 6: ...replacing is occurred Replacing packings Take off the complete plug stem as described on paragraph REPLACING STANDARD PLUG then in reference to the Fig 5 6 and 7 proceed as follow 1 Screw off the thre...

Страница 7: ...erve the right to change the design and material of this product without notice IMI PV25G 20 E 04 16 Fig 5 Packing type V Fig 6 Packing type VV Fig 7 Packing type G PARTS LIST FOR V SERIES CONTROL VAL...

Страница 8: ...tal plug and gasket 32 6 11 1 set 9 PV25P 1040 Metal plug and gasket 40 6 11 1 set 9 PV25P 1050 Metal plug and gasket 50 6 11 1 set 9 PV25P 1065 Metal plug and gasket 65 6 11 1 set 9 PV25P 1080 Metal...

Страница 9: ...et 20 2 5 10 1set 9 PV40P 1025 Metal plug and gasket 25 2 5 10 1set 9 PV40P 1032 Metal plug and gasket 32 2 5 10 1set 9 PV40P 1040 Metal plug and gasket 40 2 5 10 1set 9 PV40P 1050 Metal plug and gask...

Страница 10: ...pipe diameter in which it has to be fitted but according to the required actual flow of steam or water Refer to valve calculation data sheet or consult factory TYPICAL INSTALLATION Please consult the...

Отзывы: