background image

10/08

 

 

105715AE

 

OmniReach

®

 FTTX 

Solutions

OmniReach

®

 FTTX Solutions

RealFlex™ MDU Drop Cables

3

w w w . a d c . c o m  

•  

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0  

•  

1 - 8 0 0 - 3 6 6 - 3 8 9 1

ComPlianCes:

indoor/outdoor 

Cable

riser 

Cable

Plenum 

Cable

restriction of the use of hazardous substances rohs 
(2002/95/eC)

X

X

X

Comply with California Prop 65 for safe Drinking and 
toxic enforcement act

X

X

X

telcordia Gr-409-Core, eia/tia FotPs 
(independently verified)

X

X

X

telcordia Gr-20 tested to relevant specifications

X

X

iso/ieC 11801

X

X

X

ieC 60794-2 optical Fiber Cables Part 2

X

eia/tia 568-B

X

X

X

(Ul) 1666, neC oFnr, Ft-4

X

X

(Ul) 910, neC oFnP, Ft-6

X

Catalog number

mDC- __ __ __ __ - __ __ __ __ __ __

spool option

0

No Spool

J

Standard Spool

F

Spooled Connector First

L

Spooled Connector Last

standard Cable measurement

F

Feet

M

Meters

Connector 1 type

J

APC SC

N

UPC SC

Connector 2 type

J

APC SC

N

UPC SC

0

Stub

number of Fibers

1

One

Cable type  
(rBr) reduced Bend radius 

F

RBR Indoor/Outdoor Ivory

G

RBR Plenum Ivory

H

RBR Riser Ivory

standard Cable lengths

0010

10

0050

50

0100

100

0150

150

0200

200

0250

250

0500

500

Содержание RealFlex Drop Cables

Страница 1: ...ce the rugged 3mm cable construction provides the flexibility and durability to withstand the most demanding applications The rugged 3 mm indoor outdoor cable can be stapled allowing for fast and easy securing of cables to most surfaces The reduced bend radius glass allows the technician to staple around tight corners without compromising insertion loss performance ADC s RealFlex MDU Drop Cables p...

Страница 2: ...s distinguish cable in the field Specifications environmental Characteristics Indoor Outdoor Cable1 Riser Cable Plenum Cable Storage Temperature 40 to 75 C 40 to 70 C 40 to 70 C 40 to 167 F 40 to 158 F 40 to 158 F Operating Temperature 40 to 75 C 20 to 70 C 0 to 70 C 40 to 167 F 4 to 158 F 32 to 158 F Installation Temperature 30 to 50 C 0 to 50 C 10 to 50 C 22 to 122 F 32 to 122 F 50 to 122 F MECH...

Страница 3: ...ia GR 20 tested to relevant specifications X X ISO IEC 11801 X X X IEC 60794 2 Optical Fiber Cables Part 2 X EIA TIA 568 B X X X UL 1666 NEC OFNR FT 4 X X UL 910 NEC OFNP FT 6 X Catalog Number MDC __ __ __ __ __ __ __ __ __ __ Spool Option 0 No Spool J Standard Spool F Spooled Connector First L Spooled Connector Last Standard Cable Measurement F Feet M Meters Connector 1 Type J APC SC N UPC SC Con...

Страница 4: ...ion of this document Because we are continuously improving our products ADC reserves the right to change specifications without prior notice At any time you may verify product specifications by contacting our headquarters office in Minneapolis ADC Telecommunications Inc views its patent portfolio as an important corporate asset and vigorously enforces its patents Products or features contained her...

Отзывы: