7
2. Timed (Manual) Cycle (Mode)
a. For optional reversing models, the Phase 6 OPL microprocessor controller (computer) can be
programmed to reverse or not reverse (single direction rotation).
b. Anti-Wrinkle Program - active or non-active.
c. Drying Time - programmable from 0 to 99 minutes in one-minute increments.
d. Drying Temperature - programmable from 100º F to 200º F in one-degree increments or from 37º C to
93º C in one-degree increments.
e. Cool Down Time - programmable from 0 to 99 minutes in one-minute increments.
f. Cool Down Temperature - programmable from 70º F to 100º F in one-degree increments or from 20º C
to 37º C in one-degree increments.
g. For optional reversing models, the Spin Time can be programmed from 30-seconds to 120-seconds in
one-second increments.
h. For optional reversing models, the Stop (Dwell) Time can be programmed from 5-seconds to 10-seconds
in one-second increments.
ALL
six (6) preprogrammed cycles have been programmed by the factory as outlined on
page 51 and page 52
.
However, even though these are the most common cycles used, they
should be
reviewed to ensure they meet
the location application or needs. Should changes be found necessary, refer to the Programming Section of this
manual.
B. MANUALLY LOADED CYCLES
For occasional or one-time special loads, the operator must set the specific programs needed. This cycle is not
stored within the Phase 6 OPL microprocessor controller (computer) and
must be
entered each and every time.
The Manually Loaded Cycle can be set in either the Automatic Drying Cycle (Mode)
(Patent No. 4,827,627)
or the Timed (Manual) Drying Cycle (Mode).
Manually Loaded Cycle Selections:
1. Automatic Drying Cycle (Mode)
(Patent No. 4,827,627)
a. Drying Temperature - programmable from 160º F to 200º F in one-degree increments or from 71º C to
93º C in one-degree increments.
b. Dryness Level (percentage of extraction) - programmable from 90% (less dry) to 100% (more dry) in
one-percent increments.
c. For optional reversing models, depending on what the system parameter (program) is set for, the operator
has the choice of reverse or no reverse (single direction rotation).