SCP-PCS718-010-06H
Connections
PCS-718 List 1
January 6, 2003
31
Audible and Visual Alarm Connections
Use a wire-wrap tool to terminate the alarm leads from the external alarm equipment on the alarm relay wire-wrap
field. See
for the location of the alarm relay wire-wrap field.
shows the layout of
the wire-wrap pins on the shelf backplane.
If a remote ACO switch is to be wired, refer to the
“External ACO Connection” on page 44
for the wire-wrap pin
location.
.
Figure 10.
Connecting the Alarm Relays
U54
CCITIP
CCIRING
CC2TIP
CC2RING
U55
U56
U57
U61
U62
U64
U63
U58
U59
U60
Alarm Relay Connections
U54
MAJ AUDIBLE
MAJ VISUAL
MIN AUDIBLE
MIN VISUAL
CRIT AUDIBLE
CRIT VISUAL
SYSTEM
NO COM NC
NO COM NC
NO COM NC
NO COM NC
NO COM NC
NO COM NC
NO COM NC
C
CCI
CC2
CC2
U55
U56
U57
U61
U62