SCP-PLL735-010-03H
PLL-735 Lists 1, 2 and 3
January 6, 2003
37
System Alarm Types Screen
Allows the provisioning of the alarm types of all system alarms.
Table 9, “System Alarm Types,” on page 37
,
shows the System Alarm fields and the default settings. You can view the results of these settings from the
“Overall Status Screen” on page 21.
1
Select the
System Alarm Types
option and press
to view the screen:
Figure 31.
System Alarm Types Screen
2
With one of the alarm types selected, use the
to toggle to the desired value for the Alarm Type,
then press a directional keys to move to the next option.
3
When you have made all the desired changes, press a directional key to move to the
Accept System Alarm Types
Changes
button, and press
to accept the changes.
4
Press
to return to the DICOLU main screen, or
+ to return to the PAU/PMU main menu.
Table 9.
System Alarm Types
Alarms
Description
List 1 and 2
Defaults
List 3 Default
MISMATCHA
Incompatible RT A unit has been installed.
MN
MN
NORTSWA
RT A has no application software and is awaiting software download.
MN
MN
MISMATCHB
Incompatible RT B unit has been installed.
MN
MN
NORTSWB
RT B has no application software and is awaiting software download.
MN
MN
PMX Parity Error
The DICOLU implements parity generation and detection on the data
transferred between the PMX and the COLUs on the backplane. If
parity errors are detected coming from a PMX, an alarm is generated
and all circuits are placed in a Trunk-Conditioned state.
MN
MN
BKUPMEMP
COLU memory checksum is incorrect (EPROM Failure).
MN
MN
ENTER
SPACEBAR
ENTER
ESC
CTRL
R