ADC Telecommunications, Inc.
77
Table 14. Systems Options (Universal)
System Options
Value
Description
Default
Subscriber Test Response
Mode
NONE
Disables the test and there will be no response
TA-909
BYPASS
Connects the subscriber to the CO, bypassing
the System DLC
TA-909
Performs the subscriber drop test at the RTLU
and presents the TA-909 resistive signatures at
the Management Unit
PG-FlexPlus System ID
(24 chars max)
24 Alphanumeric
Characters maximum
Configurable identification string for the system
can be up to 24 characters. The System ID is
always visible at the bottom of every screen.
There are no special rules for changing the
System ID. Any printable characters including
spaces are valid.
PG-Flex
RT Auto Logout
DISABLED
Auto logout feature is disabled
DISABLED
5
Screens session logs out after 5 minutes of
inactivity
30
Screens session logs out after 30 minutes of
inactivity
60
Screens session logs out after 60 minutes of
inactivity
COLU Auto Logout
DISABLED
Auto logout feature is disabled
DISABLED
5
Screens session logs out after 5 minutes of
inactivity
30
Screens session logs out after 30 minutes of
inactivity
60
Screens session logs out after 60 minutes of
inactivity
Termination timeout – Metallic
Access
OFF
Termination Timeout – Metallic Access is off
OFF
30
Termination Timeout – Metallic Access times out
after 30 minutes
60
Termination Timeout – Metallic Access times out
after 60 minutes
120
Termination Timeout – Metallic Access times out
after 120 minutes