Setting the System Clock Synchronization Through the Config Menu
Figure 31.
Setting the Clock Configuration Through the HXU-359
Step
Procedure
Installer Check
ü
1
From the Config
submenu, choose Clock, and then press
.
For more information on navigating through the menu system, refer to the procedures detailed in
“Setting Up Basic System Parameters Through the Config Menu” on page 43
H
2
Press the
to select the next value, and press
to select next field.
Configure the following options:
•
Bits A
DS1 speed (default) or E1 speed
•
Bits B
DS1 speed (default) or E1 speed
•
Internal
•
Transport
•
Service #1 ~ 28
H
Continued
Main Monitor History
Config
Test Inventory Quit Help
+---------------------------Clock Configuration-----------------------+
|
|
|
+-----------------------------------------------+
|
|
|
Primary Reference
:
Bits A
|
|
|
|
DS1 speed
|
|
|
|
Secondary Reference
:
Bits A
|
|
|
|
DS1 speed
|
|
|
|
Timing Reference Switching
:
Revertive
|
|
|
|
Force
:
Normal
|
|
|
+-----------------------------------------------+
|
|
|
| (TAB) next field (Spacebar) next value (ENTER) activate (ESC) quit
|
|
|
+---------------------------------------------------------------------+
ID: | Card 'A' 10/01/01 10:42:47 ALARMS: NONE
ENTER
SPACEBAR