LTPH-TP-1044-01, Issue 1
Performance Monitoring
HXU-358 V1.04
April 6, 2001
35
When three protection switches occur within 10 minutes, the HXU-358
reports a TMS alarm. The alarm is automatically cleared in 24 hours for the
declaration of the alarm, or it can be cleared by selecting Clear TMS Count
from the Monitor menu (
Figure 21.
Monitor Menu: Clear TMS Count
A TMS alarm inhibits any protection switching between cards
until the alarm is cleared.
Protection switching of the DS3 line is inhibited when this
alarm is active.
Main
Monitor
History Config Test Inventory Quit Help
+------------------+
| PM Monitor |
| Active Alarms |
|
Clear TMS count
|
+-+--------------------------------------------------------------+
| Clear Too Many Switches count. Are you sure (Y/N)? |
+--------------------------------------------------------------+
ID: | Card 'A' 03/30/01 10:51:33 ALARMS: NONE