background image

e-sphyg

TM

Digital Aneroid

AMERICAN DIAGNOSTIC CORPORATION

FOR QUESTIONS, COMMENTS, OR SUGGESTIONS

CALL TOLL FREE:  1-800-ADC-2670

®

Care and

Maintenance

To Register Your Product, visit us at www.adctoday.com

and follow the links

LIMITED WARRANTY

Limited Warranty

American Diagnostic Corporation (ADC) warrants its products against defects in materials and
workmanship under normal use and service as follows:
1. Warranty service extends to the original retail purchaser only and commences with the date

of delivery.

2. The entire sphygmomanometer is warranted for one year.
3. The manometer is warranted to remain accurate to ±3mmHg over its full range when compared 

to a reference standard for life.

What is Covered: 

Repair, or replacement of parts, and labor.

What is not covered:

Transportation charges to and from ADC.  Damages caused by abuse, misuse,

accident, or negligence. Incidental, special, or consequential damages. Some states do not allow the
exclusion or limitation of incidental, special, or consequential damages, so this limitation may not
apply to you.

To Obtain Warranty Service:

Send item(s) postage paid to ADC, Attn: Service Dept., 55 Commerce Dr.,

Hauppauge, NY 11788.  Please include your name and address, daytime phone no., proof of purchase,
a brief note explaining the problem, and $2.00 to cover the cost of return shipping and handling.

Implied Warranty:

Any implied warranty shall be limited in duration to the terms of this warranty and

in no case beyond the original selling price (except where prohibited by law). This  warranty  gives
you  specific legal rights and  you  may  have other rights which vary from state to state.

®

AMERICAN DIAGNOSTIC CORPORATION

55 Commerce Drive • Hauppauge, NY 11788

www.adctoday.com

IB p/n 9359-00 rev 1                                                                                         Printed in the U.S.A.

NOTE - 

To obtain the greatest accuracy from your blood pressure instrument, it is

recommended that the instrument be used within a temperature range of 50°F (10°C)

to 104°F (40°C), with a relative humidity range of 40-80% (non-condensing).

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание Diagnostix e-sphyg

Страница 1: ...onsequential damages Some states do not allow the exclusion or limitation of incidental special or consequential damages so this limitation may not apply to you To Obtain Warranty Service Send item s postage paid to ADC Attn Service Dept 55 Commerce Dr Hauppauge NY 11788 Please include your name and address daytime phone no proof of purchase a brief note explaining the problem and 2 00 to cover th...

Страница 2: ...you for your patronage It is indeed our pleasure to serve you Sincerely American Diagnostic Corp 2005 AMERICAN DIAGNOSTIC CORP NAME FUNCTION OF PARTS Gauge Hang Tab Arm Cuff Gauge Backlight Button On Off Zeroing Button Artery Mark Air Tube and Connector Air Release Valve Inflation Bulb Error Message Description Solution ERROR MESSAGES Err Heartbeat rate detection error The cuff was deflated too ra...

Страница 3: ...liability exceeding the most popular aneroid models While tradi tional mechanical gauges can be easily knocked out of calibration when dropped your digital gauge will remain accurate even when subjected to rough treatment With its helpful on screen calibration reminder you will be able to use your new digital gauge with confidence and with the knowledge that it will remain calibrated beyond the li...

Страница 4: ...ncil directive 93 42 EEC EMC directive 89 336 EEC EN 1060 1 1995 Non invasive sphygmomanometers Part 1 General Requirements EN 1060 3 1997 Non invasive sphygmomanometers Part 3 supplementary requirements for electro mechanical blood pressure measuring systems ANSI SP10 To ensure the reliable operation of this sphygmomanometer use it in temperatures ranging from 50 F 10 C to 104 F 40 C The sphygmom...

Страница 5: ...dder around the arm snugly and smoothly and engage adhesive strips To verify a correct fit check that the Index Line falls between the two Range Lines CALIBRATION OF THE DIGITAL GAUGE Gauge accuracy can be checked visually whenever it is switched on If the unit is used more than 10 000 times a calibration reminder message CAL will appear on the digital display Any digital gauge that displays this ...

Страница 6: ...e Remove cuff BACKLIGHT CONTROL The default setting on your digital gauge is to have the back light on once the pressure is inflated over 30 mmHg and throughout the measurement process To switch the backlight off at any time press the button on the left side You will need to deactivate the backlight each time you power on the instrument CARE AND MAINTENANCE Storage After measurement wrap cuff arou...

Отзывы: