Cuff

Coiled Tubing

Bulb

Valve

Manometer

ADC Aneroid Sphygmomanometer

(manometer, cuff, bladder, bulb and valve)

Thank you for choosing an ADC 

Diagnostix Aneroid Sphygmomanometer. Your new

aneroid is designed to provide unrivaled durability and unparalleled comfort. Every

component has been carefully designed to maximize performance. This Instructions

for Use guide refers to ADC model series 700, 703, 705, 720, 728, 731, 732, 740,

750, 752, 778, and 788.

Device Description and Intended Use

ADC aneroid sphygmomanometers are used by professional healthcare providers and

individuals trained in the auscultatory blood pressure technique to determine systolic

and diastolic blood pressure in humans. 

Contraindications: 

Aneroid sphygmomanometers

are contraindicated for neonate use.

Do not use with neonatal cuffs or

neonate patients. Review the size

chart for proper age and limb range

usage (right).

Symbol Definitions

The following symbols are associated with your ADC Diagnostix Aneroid

General Warnings

A warning statement in this manual identifies a condition or practice
which, if not corrected or discontinued immediately, could lead to patient
injury, illness, or death.

      

WARNING: 

Do not allow a blood pressure cuff to remain on patient for more 

      than 10 minutes when inflated above 10 mmHg. This may cause patient distress, 

      disturb blood circulation, and contribute to the injury of peripheral nerves.

      WARNING: 

If luer lock connectors are used in the construction of tubing,

      there is a possibility that they might be inadvertently connected to intra-vascular

      fluid systems, allowing air to be pumped into a blood vessel. Immediately consult a 

       physician if this occurs.

      WARNING: 

Safety and effectiveness with neonate cuff sizes 1 through 5 is 

      not established.

      WARNING: 

If this equipment is modified, appropriate inspection and testing 

      must be conducted to ensure its continued safe use.

      WARNING:

Do not apply cuff to delicate or damaged skin. Check cuff site 

      frequently for irritation.

      WARNING:

Only use the cuff when the range markings indicated on the cuff 

      show that the proper cuff size is selected, otherwise erroneous readings 

      may result.

      WARNING:

Allow space between patient and cuff. Two fingers should fit in 

      this space if the cuff is correctly positioned.

      WARNING:

Do not apply cuff to limbs used for IV infusion.

      WARNING:

Patient should remain still during measurement to avoid 

      erroneous readings.

      WARNING:

When using with an infant or child cuff, extra care must be taken to 

      prevent over-inflation. With smaller cuffs (infant or child) the cuff can inflate to 

      over 300mmHg with just two full compressions of the bulb.  To prevent discomfort

      or injury to the patient and damage to the instrument, bulb should only be partially

      squeezed, so that each “stroke” inflates the cuff in 40mmHg to 60mmHg increments

      until inflated to the desired level.

      CAUTION: 

To obtain the greatest accuracy from your blood pressure instrument,

      it is recommended that the instrument be used within a temperature range of 

      50°F (10°C) to 104°F (40°C), with a relative humidity range of 15%-85% 

      (non-condensing).

      CAUTION: 

Extreme altitudes may affect blood pressure readings. Your device 

      has been designed for normal environmental conditions.

Operation of Diagnostix Pocket Aneroids

This booklet contains operating and

maintenance information for the

Diagnostix 700, 720, 728, and 778

Series pocket aneroid sphygmo-

manometers. Please read and retain.

Your Diagnostix brand pocket

aneroid sphygmomanometer

consists of an aneroid manometer

(gauge), complete inflation system

(Adcuff calibrated nylon cuff, latex-

free inflation bladder, squeeze bulb,

and Adflow valve), a zippered carry-

ing case, and operating instructions.

Most models are preassembled and ready for use. In units requiring assembly, the

bulb and valve should connect to the tube closest to the Index Line. The gauge con-

nects to the remaining tube.

Operation of Diagnostix
Palm Aneroids

This booklet contains operating and           

maintenance information for the                  

Diagnostix 703 Series, 788 Series,               

System 3, Pediatric, General Practice,

System 4, and System 5 Multicuff                

instruments. Please read and retain.

Cuff

Index Line

Hang Tab

Gauge

Artery Mark

Bulb & Valve

Bladder &

Tubing

Your Diagnostix palm-style aneroid manometer with integral bulb and trigger air release

valve (#804N), Adcuff calibrated cuff with Size Guide

marking system, bladder, bayonet-

style connector (attached to bladder tubing), zippered carrying case, and instruction book-

let. ADC’s Multicuff Systems (System 3, 4, 5, GPK, and PMK) contain the #804N manome-

ter and a variety of cuffs with single tube bladders, each equipped with a bayonet-style

connector, and a compartmentalized case.

Connecting Palm Style Model: 804N

Legacy Connector:

Assemble the supplied luer slip   

connector into the connector port on top of palm gauge,

rubber gasket side down. Make sure connector is fully 

seated in the connector port. Slide cuff tubing over the

barbed end of the connector. Connector will friction fit onto

the tubing of most commercially available ONE-tube cuff 

and bladder systems (Figure 1).

New 804N Connector:

Insert white bayonet connector

into metal receiver until it clicks (Figure 2).

To Release:

Slide receiver collar downward toward gauge

until connector releases.

WARNING: 

Do 

NOT

remove metal receiver from gauge.

WARNING:

The palm style manometer is designed

for use with ONE-tube systems.

WARNING:

To avoid damage to the instrument, do not force

connector into port.

Using the Trigger Valve

Deflation: 

Gently squeeze the bottom of the trigger to deflate the cuff.

Altering the pressure affects the deflation rate.

Rapid Exhaust:

To exhaust remaining air after measurement is 

completed, squeeze trigger until it clicks and locks in place.

Caution: Never force trigger.

Operation of Diagnostix Clock Aneroids

This booklet contains operating and maintenance information 

for the Diagnostix 750W series (wall mount), 752M series 

(mobile), and 750D series (desktop) aneroid                  

sphygmomanometers. Please read and retain.

Your Diagnostix 750/752 consists of a large                  

“clockface” aneroid with easy-to-read 6” dial, an           

integral swivel bracket/cuff storage compartment           

(wall series only), complete inflation system                  

(which includes the Adcuff nylon cuff with Size

Guide marking system, latex-free inflation                      

bladder, bulb, and Adflow valve), 8-foot length coiled tubing,

luer connectors, mounting hardware, and operating instructions. The Diagnostix 752M is

mounted on a height adjustable, Spider-Leg

5-leg mobile stand. The Diagnostix 750D is

mounted on a desktop stand.

To assemble the inflation system, connect coiled tubing to air inlet nipple at bottom of gauge.

Insert male luer adapter on bladder tubing into female receptacle at free end of coiled tubing.

Store folded inflation system in swivel bracket behind gauge on 750W and 750D or in integral

basket on 752M.

Adcuff Intended Use:

ADC blood pressure cuffs are noninvasive and are intended for use with manual and

automated noninvasive blood pressure measurement devices. 

ADC’s Size Guide marking system assures use of correct cuff size and proper cuff

alignment.  Printed Index and Range markings and applicable limb range (in cm)

allow easy identification of the correct cuff size.  An artery mark printed on both sides

indicates bladder midpoint for correct cuff positioning.  A convenient nylon gauge

hang tab permits flexible use with either pocket aneroids or mercury manometers.

Hook-and-loop adhesive surface provides a snug, infinitely variable fit and is

designed to withstand a minimum of 30,000 open/close cycles.

Measurement Procedure

Patient Position

The patient should sit or lie comfortably. The arm should be fully supported on a

flat surface at heart level. (If the arm’s position varies, or is not level with the heart,

measurement values obtained will not be consistent with the patient’s true blood

pressure.) When seated, the patient should have their back and arm supported, and

their legs should not be crossed. Prior to measurement the patient should relax

comfortably for five minutes and should refrain from talking or moving during

measurement. Observer should view manometer in a direct line to avoid “parallax error.”

Apply the cuff

Adcuff nylon cuffs are specially designed

to promote the precisely accurate determi-

nation of blood pressure. Index and range

markings ensure use of the                         

correct cuff size. The artery mark                

indicates proper cuff positioning.

Place the cuff over the bare upper arm with the artery mark positioned directly over

the brachial artery. The bottom edge of the cuff should be positioned approximately

one inch (2-3cm) above the antecubital fold. Wrap the end of the cuff not containing

the bladder around the arm snugly and smoothly and engage adhesive strips (Figure 3).

To verify a correct fit, check that the Index Line falls between the two Range Lines

(Figure 4).

Left Arm

Tube

(Figure 3)

      

Cuff        Size 

Limb Range  

                                  

Inches             CM

     Infant          

7I         3.5 to 5.5          9 to 14

      Child          

9C         5.1 to 7.6       13 to 19.5

 Sm. Adult    

10SA     7.4 to 10.6        19 to 27

      Adult         

11A        9 to 15.7         23 to 40

  Lg. Adult      

12X     13.3 to 19.6       34 to 50

     Thigh         

13T     15.7 to 25.9       40 to 66

   Bariatric     

12BX    17.3 to 25.9       44 to 66

Size Chart

Ind

ex

 Lin

e

 

TM

13

T

12

X

10
SA

9
C

7

I

11

A

Adult - 11

23-40 cm

11

TM

23-40 cm

Reusable BP Cuff

11

Gauge Hang Tab

Bladder Flap

Artery Mark

Size Icons

Hook & Loop

Closure Adhesive

Range Lines

Index Line

Artery Mark

 

In

de

Li

ne

   

 

 

   

 

In

de

Li

ne

   

 

 

   

Range Lines

Index Line

Artery Mark

Select Smaller Cuff

Correct Cuff Size

Select Larger Cuff

(Figure 4)

Cuff

Bladder Tubing

Trigger Valve

Gauge

Artery Mark

Connector Port

(Figure 1)

(Figure 2)

Symbol    

Definition

                

Important warning/caution

                  
                  
                  

                  Phthalate free

                  Circumference size

LATEX

Symbol    

Definition

                

                

Conforms to EU standards

                   Authorized European

                 represenative’s information

                  Manufacturer’s information

                  Temperature limit

                  Humidity limitation

°

F

Not made with natural
rubber latex

9350N-00 rev 9_Layout 1  4/17/19  8:40 AM  Page 2