![ADC and V35 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/adc/and-v35/and-v35_user-manual_2848176031.webp)
ADCP-50-304 • Issue 19 • June 1999 • Section 2: Functional Description
Page 2-11
© 1999, ADC Telecommunications, Inc.
3.3
Patch Module with A/B Switching and In-Line Patch Access (PSM-02)
This PS module operates similarly to the PSM-01 by providing patching, switching, and switch
status indication, except it does not contain LED status indicators and alarm circuitry. A detailed
circuit diagram of this module is shown in
.
Table 2-4. LED Status Indicators
LED STATUS INDICATOR
COLOR
SIGNAL DEFINITION
A
Red
DTE-A
B
Green
DTE-B
TD
Green
Transmitted Data
RD
Green
Received Data
DCD
Green
Data Carrier Detect
SQ
Green
Signal Quality Detect
RTS
Red
Request To Send
CTS
Red
Clear To Send
DSR
Red
Data Set Ready
DTR
Red
Data Terminal Ready
ALM
Yellow
Alarm On
Table 2-5. Alarm Time Delay Settings
TIME DELAY
ARC LENGTH
50 HZ AND 60 HZ ENVIRONMENT
γ
1 µsec
Shortest
64 msec
256 msec
0.51 sec
1.02 sec
8.19 sec
32.75 sec
Longest
65.5 sec