Retain This Manual In A Safe Place For Future Reference

American Dryer Corporation

 products embody advanced concepts in engineering, design, and safety.  If this

product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation.

ONLY properly licensed technicians should service this equipment.

OBSERVE

 

ALL

 

SAFETY

 

PRECAUTIONS

 displayed on the equipment or specified in the installation/operator's

manual included with the dryer.

THE HSI MODULE IS

 

NOT FIELD REPAIRABLE

and

THE HSI GAS VALVE IS

 

NOT FIELD REPAIRABLE

We have tried to make this manual as complete as possible and hope you will find it useful.  

ADC

 reserves the

right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and material,
and to change or discontinue models.

WARNING: UNDER

 

NO

 

CIRCUMSTANCES

 

should the door switch or the heat circuit devices

ever be disabled

.

WARNING: The dryer must never be operated with any of the back guards, outer tops, or

service panels removed.  PERSONAL INJURY or FIRE COULD RESULT.

NOTE

: The wiring diagram for the dryer is located on the right wall, inside the Left Coin Panel area.

Replacement parts can be obtained from your distributor or the 

ADC

 factory.  When ordering replacement parts

from the factory, you can FAX your order to 

ADC

 at (508) 678-9447 or telephone your orders directly to the

ADC

 Parts Department at (508) 678-9010.  Please specify the dryer 

model

 

number

 and 

serial

 

number 

in

addition to the 

part number

 and 

part description

, so that your order is processed accurately and promptly.

The illustrations on the following pages may not depict your particular dryer exactly.  The illustrations are a
composite of the various dryer models.  Be sure to check the descriptions of the parts thoroughly before ordering.

                          INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER

       SMELLS GAS MUST BE POSTED IN A PROMINENT LOCATION. THE
       INSTRUCTIONS TO BE POSTED SHALL BE OBTAINED FROM THE
       LOCAL GAS SUPPLIER.

Содержание ADG-530

Страница 1: ...ace Ignition System Technical Manual American Dryer Corporation 88 Currant Road Fall River MA 02720 4781 USA Telephone 1 508 678 9000 Fax 1 508 678 9447 e mail techsupport amdry com www amdry com ADC...

Страница 2: ...evices ever be disabled WARNING The dryer must never be operated with any of the back guards outer tops or service panels removed PERSONAL INJURY or FIRE COULD RESULT NOTE The wiring diagram for the d...

Страница 3: ...ation contained herein may have been up dated ADC RESERVES THE RIGHT TO MAKE CHANGES FROM TIME TO TIME WITHOUT NOTICE or OBLIGATION IN PRICES SPECIFICATIONS COLORS and MATERIALS and TO CHANGE or DISCO...

Страница 4: ...I system When activated by the dryer s controls this module constantly monitors and controls the functions of the 1 Failure To Light LOCKOUT a Should the main burner fail to light or if a flame is not...

Страница 5: ...go into LOCKOUT If flame is reestablished normal operation resumes IMPORTANT The HSI MODULE is a precision instrument and should be handled carefully ROUGH HANDLINGor DISTORTINGCOMPONENTS COULD CAUSE...

Страница 6: ...mbly c The HOT SURFACE IGNITOR FLAME SENSOR ASSEMBLY is located in the burner flame area and is used to ignite the gas by the use of a HOT SURFACE IGNITOR To provide feedback information to the HSI mo...

Страница 7: ...3 TRIALFORIGNITIONPERIOD 4 seconds INTER PURGE 3 5 seconds C HSI Hot Surface Ignition SYSTEM OPERATION 1 HSI SYSTEM OPERATION a The HSI Module s red indicator light will light for up to approximately...

Страница 8: ...nternal Routine Check L E D Indicator Stays On Approx 4 Seconds Hot Surface Ignitor Starts To Glow If L E D Indicator Stays On Continuously Replace HSI Module If L E D Continuously Blinks Twice in Suc...

Страница 9: ...the Gas Valve is de energized and the HSI Module controller goes through an inter purge delay before another ignition cycle is attempted The HSI Module will attempt two 2 additional ignition trials b...

Страница 10: ...of the system c FLAMEOUT burner flame shut down by the HSI Module due to lack of flame verification This condition occurs only after ignition has been evident but is lost The HSI system will immediat...

Страница 11: ...a soapy water solution NEVER TEST FOR LEAKS WITH A FLAME a Connect water column test gauge manometer to the gas valve tap 1 8 N P T f FLAME SENSOR FAULT if there is a problem fault within the flame se...

Страница 12: ...HSI Module is equipped with a diagnostic circuit that detects a fault in the Flame Sensor Probe or any related circuits in the internal circuits in the HSI module When a fault is detected the red L E...

Страница 13: ...LE if it is in the LOCKOUT MODE or the FLAME SENSOR FAULT MODE open and close the main door then restart the dryer 3 HSI Hot Surface Ignition Module The HSI module controller utilizes a microprocessor...

Страница 14: ...ice Department they must be given the correct model number and serial number of the dryer s NOTE Any wiring change s and or conversion s should be by a QUALIFIED ELECTRICAL TECHNICIAN 1 Transformer Wi...

Страница 15: ...placed 36E Redundant Gas Valve 4 HSI Hot Surface Ignition 24 VAC Redundant Gas Valve IMPORTANT The HSI 24 VAC Redundant Gas Valve contain no serviceable parts REPLACEMENT COILS ARE NOT AVAILABLE IMPOR...

Страница 16: ...promptly The information and illustrations listed here may not depict your particular dryer part exactly This information and or illustrations are a composite of the HSI SYSTEM Be sure to check the p...

Страница 17: ...15 HSI Hot Surface Ignition SYSTEM COMPONENTS 24 VAC Transformer Hot Surface Ignition HSI Module 36E 24 VAC Redundant Gas Valve Upshot Burner Tube with Hot Surface Ignitor HSI Flame Sensor Assembly...

Страница 18: ...ADC Part No 450401 3 12 15 08 0...

Отзывы: