4) HSI (Hot Surface Ignition) 24 VAC Transformer

The HSI transformer is designed to step down the operating voltage of the dryer to
24 VAC to operate the HSI module.  This transformer, like all transformers, is two (2)
sided:

a ) Primary Side

This is the incoming voltage side - 120 VAC, 208 VAC, 240 VAC - of transformer.

b) Secondary Side

This is the step down side - 24 VAC - of the transformer.

WARNING

:

208 VAC and 230/240 VAC

 

ARE

 

NOT

 

THE

 

SAME.  ALL

 voltage

connections 

should be

 checked and confirmed according to the wiring

diagram provided with the individual dryer.  Any damage done to dryer
components due to improper voltage connections will automatically
VOID  THE  WARRANTY.

IMPORTANT

: The 

ADC

 Service Department 

must be

 contacted prior to any wiring

change and/or conversion because, depending on the change/
conversion required, some parts may have to be added, deleted, or
changed.  When contacting the 

ADC

 Service Department they 

must be

given the correct 

model number

 and 

serial number

 of the dryer(s).

NOTE

:  Any wiring change(s) and/or conversion(s) s

hould be

 by a

 QUALIFIED

ELECTRICAL TECHNICIAN

.

(1) Transformer Wiring

There are six (6) color-coded wires coming from the 24 VAC Transformer.  There
are four (4) wires coming from the primary (incoming) voltage side of the trans-
former.  Their application and color-coding are as follows:

There are 

two (2) ORANGE

 wires coming from the secondary (step down) side

of the transformer;

(d) One (1) ORANGE wire is connected to the GND (ground) termination.
(e) One (1) ORANGE wire supplies the 24 VAC signal for the control and/or HSI system

circuit.  (Refer to the specific wiring diagram with the dryer for connection point.)

(a)

For  120 VAC application ONLY;

1 - The

 BLACK

 and 

WHITE 

wires are used.

2 - The  Red and Blue wires are capped off

individually.

(b)

For  208 VAC application ONLY;

1 - The

  BLACK

 and 

BLUE 

wires are used.

2 - The  Red and White wires are capped off

individually.

(c)

For  240 VAC application ONLY;

1 - The

  BLACK

 and 

RED 

wires are used.

2 - The  White and Blue wires are capped off

individually.

Содержание ADG-530

Страница 1: ...ace Ignition System Technical Manual American Dryer Corporation 88 Currant Road Fall River MA 02720 4781 USA Telephone 1 508 678 9000 Fax 1 508 678 9447 e mail techsupport amdry com www amdry com ADC...

Страница 2: ...evices ever be disabled WARNING The dryer must never be operated with any of the back guards outer tops or service panels removed PERSONAL INJURY or FIRE COULD RESULT NOTE The wiring diagram for the d...

Страница 3: ...ation contained herein may have been up dated ADC RESERVES THE RIGHT TO MAKE CHANGES FROM TIME TO TIME WITHOUT NOTICE or OBLIGATION IN PRICES SPECIFICATIONS COLORS and MATERIALS and TO CHANGE or DISCO...

Страница 4: ...I system When activated by the dryer s controls this module constantly monitors and controls the functions of the 1 Failure To Light LOCKOUT a Should the main burner fail to light or if a flame is not...

Страница 5: ...go into LOCKOUT If flame is reestablished normal operation resumes IMPORTANT The HSI MODULE is a precision instrument and should be handled carefully ROUGH HANDLINGor DISTORTINGCOMPONENTS COULD CAUSE...

Страница 6: ...mbly c The HOT SURFACE IGNITOR FLAME SENSOR ASSEMBLY is located in the burner flame area and is used to ignite the gas by the use of a HOT SURFACE IGNITOR To provide feedback information to the HSI mo...

Страница 7: ...3 TRIALFORIGNITIONPERIOD 4 seconds INTER PURGE 3 5 seconds C HSI Hot Surface Ignition SYSTEM OPERATION 1 HSI SYSTEM OPERATION a The HSI Module s red indicator light will light for up to approximately...

Страница 8: ...nternal Routine Check L E D Indicator Stays On Approx 4 Seconds Hot Surface Ignitor Starts To Glow If L E D Indicator Stays On Continuously Replace HSI Module If L E D Continuously Blinks Twice in Suc...

Страница 9: ...the Gas Valve is de energized and the HSI Module controller goes through an inter purge delay before another ignition cycle is attempted The HSI Module will attempt two 2 additional ignition trials b...

Страница 10: ...of the system c FLAMEOUT burner flame shut down by the HSI Module due to lack of flame verification This condition occurs only after ignition has been evident but is lost The HSI system will immediat...

Страница 11: ...a soapy water solution NEVER TEST FOR LEAKS WITH A FLAME a Connect water column test gauge manometer to the gas valve tap 1 8 N P T f FLAME SENSOR FAULT if there is a problem fault within the flame se...

Страница 12: ...HSI Module is equipped with a diagnostic circuit that detects a fault in the Flame Sensor Probe or any related circuits in the internal circuits in the HSI module When a fault is detected the red L E...

Страница 13: ...LE if it is in the LOCKOUT MODE or the FLAME SENSOR FAULT MODE open and close the main door then restart the dryer 3 HSI Hot Surface Ignition Module The HSI module controller utilizes a microprocessor...

Страница 14: ...ice Department they must be given the correct model number and serial number of the dryer s NOTE Any wiring change s and or conversion s should be by a QUALIFIED ELECTRICAL TECHNICIAN 1 Transformer Wi...

Страница 15: ...placed 36E Redundant Gas Valve 4 HSI Hot Surface Ignition 24 VAC Redundant Gas Valve IMPORTANT The HSI 24 VAC Redundant Gas Valve contain no serviceable parts REPLACEMENT COILS ARE NOT AVAILABLE IMPOR...

Страница 16: ...promptly The information and illustrations listed here may not depict your particular dryer part exactly This information and or illustrations are a composite of the HSI SYSTEM Be sure to check the p...

Страница 17: ...15 HSI Hot Surface Ignition SYSTEM COMPONENTS 24 VAC Transformer Hot Surface Ignition HSI Module 36E 24 VAC Redundant Gas Valve Upshot Burner Tube with Hot Surface Ignitor HSI Flame Sensor Assembly...

Страница 18: ...ADC Part No 450401 3 12 15 08 0...

Отзывы: