Non-Coin Programming _______________

To Enter Programming Mode

Press        And       Keys Together

To Exit Programming Mode Press        Multiple Times

Until Display Returns to “Ready”.

0:

SELECT LANGUAGE

1:

SELECT SYSTEM PARAMETERS

0: DRYER SETUP

0: SELECT MODEL
1: SYSTEM TEMP
2: ENTER LINT COUNT 1 TO 5
3: ENTER AUDIO ALERT ON TIMES 0 TO 10
4: ROTATION SENSOR

1: REVERSING SETUP

0: ENTER SPIN TIME 30 TO 120 SECONDS
1: ENTER STOP TIME 5 TO 10 SECONDS

WRINKLE GUARD SETUP

2: 0: WRINKLE GUARD AUDIO ALERT
3: STEAM INJECTION SETUP

2:

PROGRAM A - F CYCLES
ENTER A - F
SELECT CYCLE TYPE
AUTO

0:

REVERSE MODE

1:

ENTER DRY TEMP 160 (71) TO 200 F (94 C) *

2:

ENTER DRYNESS LEVEL

3:

ENTER CYCLE ADJUSTMENT VALUE 0 TO 99

4:

CONTROLLED COOL DOWN

5:

ENTER COOL DOWN TIME 0 TO 99 MINUTES

6:

ENTER COOL DOWN TEMP 70 (21) TO 100 F (38 C)

MANUAL

0:

REVERSE MODE

1:

ENTER DRY TIME 0 TO 99 MINUTES

2:

ENTER DRY TEMP 100 (38) TO 200 F (94 C) *

3:

CONTROLLED COOL DOWN

4:

ENTER COOL DOWN TIME 0 TO 99 MINUTES

5:

ENTER COOL DOWN TEMP 70 (21) TO 100 F (38 C)

6:

STEAM INJECTION

3:

PROGRAM 0 - 40 CYCLES
ENTER 0 - 40
SELECT CYCLE TYPE
AUTO

0:

REVERSE MODE

1:

ENTER DRY TEMP 160 (71) TO 200 F (94 C) *

2:

ENTER DRYNESS LEVEL

3:

ENTER CYCLE ADJUSTMENT VALUE 0 TO 99

4:

CONTROLLED COOL DOWN

5:

ENTER COOL DOWN TIME 0 TO 99 MINUTES

6:

ENTER COOL DOWN TEMP 70 (21) TO 100 F (38 C)

MANUAL

0:

REVERSE MODE

1:

ENTER DRY TIME 0 TO 99 MINUTES

2:

ENTER DRY TEMP 100 (38) TO 200 F (94 C) *

3:

CONTROLLED COOL DOWN

4:

ENTER COOL DOWN TIME 0 TO 99 MINUTES

5:

ENTER COOL DOWN TEMP 70 (21) TO 100 F (38 C)

6:

STEAM INJECTION

4:

DEFAULT SETTING

FAULT HISTORY

5: SAFE SYSTEM VALVE TEST        OR     +  A

DISPLAY:      

   

SAFE TEMP  

 

   TUMBLER TEMP 

    

 CTL VAC / RPM

* 160 F (71 C) MAXIMUM TEMP ON AXIAL MODELS

Phase 7.2 Non-Coin Diagnostic Codes

MAIN DOOR OPENED – A main door or door circuit is open.
EXHAUST HIGH TEMP FAULT – Tumbler is above 220° F
(104° C).
LINT ACCESS OPEN – Lint drawer or lint door circuit is open.
EXHAUST HIGH LIMIT FAULT – Temp. disk under tumbler is
open.
SAIL SWITCH CLOSED FAULT – Sail switch is closed –
should be open at the start of a cycle.

O

O

O

SAIL SWITCH OPEN FAULT – Sail switch remained open after
the cycle started.  Should have closed.
BURNER HIGH LIMIT FAULT – Burner temp. disk has opened.
BURNER IGNITION CONTROL – No signal to gas valve from
(DSI) module during trial for ignition time.  DSI module is bad.
IGNITION FAULT – Gas valve did not remain open after trial
for ignition.  Indicates that no flame was detected.
FLAME FAULT – Flame was detected during trial for ignition
but failed later.
ROTATION FAULT – Indicates the tumbler is not rotating.
OPEN EXHAUST TEMPERATURE PROBE – Indicates the
exhaust temperature probe is open or shorted.
OPEN FIRE SUPPRESSION SYSTEM (F.S.S.) PROBE FAULT
– Indicates the temperature probe for the F.S.S. is open or
shorted.
LOW VOLTAGE FAULT – Volt dropped below the operating
value.
EE PROM FAULT ### – Error in memory location.  Fault
correction:
Enter the program mode by pressing the UP and STOP keys.
Press “4” and ENTER keys in password “FAA” Press UP
ARROW.
Press enter to confirm reset of EE PROM.

Inputs (Red L.E.D.s)

All indications are with L.E.D. lit

ESTOP – Indicates E-STOP has been pressed.
GAS_V – Indicates the gas valve is open (ON).
BRHL – Indicates the burner high limit disk is closed
(temperature below 330° F [166° C]).
SAIL – Indicates the sail switch is closed.
EXHL – Indicates the exhaust high limit disk is closed
(temperature below 225° F [107° C]).
MAIN – Indicates the status of main door is closed.
LINT – Indicates the lint drawer is closed.
FUSE – Indicates the status of the control voltage after
POWER ON button has been pressed.

Outputs (Green L.E.D.s)

All indications are with L.E.D. lit

AUX – This is for a spare output to be programmed.
STEAM – Indicates the status of the steam injection output.
_HEAT – Indicates the status of the heat output.
AIR – Indicates the status of the air jet output.
REV – Indicates the status of the tumbler reverse direction
output.
If the request to tumble the drum in the reverse direction is
made, then the L.E.D. is ON.
FWD – This L.E.D. will indicate the status of the tumbler
forward direction output.
FAN – This L.E.D. will indicate the status of the fan output.

O

Содержание AD120i

Страница 1: ...isin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent tre assur s par un installateur ou...

Страница 2: ...ur order is processed accurately and promptly These instructions are only valid if the following country code is on the appliance If this code is not present on the appliance it is necessary to refer...

Страница 3: ...he following installation instructions apply Installations and repairs must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the State of Massachusetts...

Страница 4: ...terials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produc...

Страница 5: ..._ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ _________...

Страница 6: ...IRBORNE SOUND LEVEL 69 dB A DRYERS PER 20 40 CONTAINER 4 9 DRYERS PER 48 53 TRUCK 10 12 VOLTAGE AVAILABLE 208 480V 1 3 2 3 4w 50 60 Hz APPROXIMATE NET WEIGHT 1 440 lb 653 17 kg APPROXIMATE SHIPPING WE...

Страница 7: ...claundry com 7 NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation Specifications ______________________________________________________...

Страница 8: ...tible construction as noted in this manual refer to Dryer Enclosure Requirements section Provisions must be made for adequate clearances for servicing and for operation as noted in this manual refer t...

Страница 9: ...onsole Module 1 Remove the outer top top back guard bottom back guard and rear electrical box cover refer to the Component Identification drawing 2 Remove 8 bolts washers and lock washers L figure 1 t...

Страница 10: ...o its mating plug This plug is similar to the one in the lower right corner that was disconnected earlier 9 Reinstall the retaining screws top and bottom 10 Reinstall the bottom hinge block This was t...

Страница 11: ...e exhaust ductwork system Exhaust back pressure measured by a manometer magnehelic in the exhaust duct must be no less than 0 and must not exceed 0 7 in WC 1 7 mb Fresh Air Supply Requirements _______...

Страница 12: ...e nearest obstruction refer to the diagram Exhaust Transition Piece This dryer is equipped with a 12 inch to 10 inch exhaust transition piece installed for use with 10 inch ducting If the exhaust duct...

Страница 13: ...proper venting information Multiple Dryer Common Venting If it is not feasible to provide separate exhaust ducts for each dryer ducts from individual dryers may be channeled into a common main duct T...

Страница 14: ...14 American Dryer Corp 113546 2 MULTIPLE DRYER VENTING HORIZONTAL AT COMMON DUCT MULTIPLE DRYER VENTING VERTICAL AT COMMON DUCT...

Страница 15: ...wire size 4 24 14 Not available until September 2014 Grounding A ground earth connection must be provided and installed in accordance with local state and national regulations or codes of the country...

Страница 16: ...be grounded A ground lug has been provided for this purpose Input connection wiring must be sized properly to handle the dryer s current draw This information is printed on the dryer s rating plate I...

Страница 17: ...re the input wiring enters 3 Phase 3 Wiring Connections Hookup The electrical connections on all 3 phase 3 gas and steam dryers are made into the rear service box located at the upper left area of the...

Страница 18: ...atings shown on the rating plate are for elevations up to 2 000 feet 610 meters unless elevation requirements of over 2 000 feet 610 meters were specified at the time the dryer order was placed with t...

Страница 19: ...Input Gas Consumption Orifice Injector Data For CE European Models Only GAS SPECIFICATIONS FOR NON CE APPROVED DRYERS Gas Type Nominal Heating Value Supply Pressure Gross Heat Input Orifice Size Orif...

Страница 20: ...ccessible for a pressure gauge connection must be installed in the main gas supply line immediately upstream of the dryers IMPORTANT Pipe joint compounds that resist the action of natural L P and buta...

Страница 21: ...tructions included in kit envelope 92 1022 supplied 9 To convert the gas valve for use with regulated L P gas refer to the instructions included in kit envelope 92 0659 supplied 10 Reverse procedure f...

Страница 22: ...ly a glass or transparent plastic tube with a scale graduated in inches or millibars When it is filled with water and pressure is applied the water in the tube rises showing the exact gas pressure Gas...

Страница 23: ...ly in place Be sure the lint door drawer is securely in place Rotate the tumbler drum by hand to be sure it moves freely Check bolts nuts screws terminals and fittings for tightness and security Check...

Страница 24: ...mation ___________ Service Service must be performed by a qualified trained technician If service is required contact the reseller from whom the equipment was purchased If the reseller cannot be conta...

Страница 25: ...t be accepted IMPORTANT No replacements credits or refunds will be issued if the claim cannot be processed due to insufficient information The party filing the claim will be notified in writing either...

Страница 26: ...exhaust and ventilation gases reducing dryer performance Cleaning of the dryer s internal exhaust may require removing the lint screen See the instructions above for removing the lint screen Check an...

Страница 27: ...____ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______...

Страница 28: ...IL SWITCH CLOSED FAULT Sail switch is closed should be open at the start of a cycle O O O SAIL SWITCH OPEN FAULT Sail switch remained open after the cycle started Should have closed BURNER HIGH LIMIT...

Страница 29: ...closed before starting SAIL SWITCH OPEN Sail switch failed to close after starting BURNER HI LIMIT Oven thermostat switch has opened EXHAUST HI LIMIT Tumbler thermostat switch has opened BURNER CONTRO...

Страница 30: ...ADC Part No 113546 2 08 13 14...

Отзывы: