113546 - 2
www.adclaundry.com
21
Parts Required for Conversion:
Description
P/N
Qty
Unregulated L.P. Gas Conversion Kit
***
140419
1
OR
Regulated L.P. Gas Conversion Kit
****
140413
1
Burner Orifice (Injector)
**
3
*
New Rating Plate (CE Only)
*****
1
L.P. Conversion Label (Non-CE Only)
112011
1
L.P. Conversion Rating Plate Addendum
(Non-CE Only)
114090
1
L.P. Confirmation Label (Non-CE Only)
114083
1
*
This includes one for each burner tube.
**
Refer to
page 19
for orifice (injector) size.
*** Required for unregulated propane or butane only.
**** Required for regulated LPG or propane only.
***** Contact ADC.
Instructions
1.
Discontinue electrical power to the dryer.
2.
Close all shutoff valves in the dryer gas supply line.
3.
Disconnect gas valve wiring.
“CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper operation.”
«ATTENTION: Lor des opérations d’entretien des
commandes étiqueter tous fils avant de les
déconnecter. Toute erreur de câblage peut étre une
source de danger et de panne.»
4.
Remove (4) screws holding heat deflector, then move it
to the right approximately 4-inches as shown in figure 5.
5.
Break union connection (nut) between the external shutoff
and the gas valve.
6.
Remove (4) screws from the brackets that are holding
the gas valve/manifold assembly to the top console base.
Remove the gas valve/manifold assembly from the dryer.
7.
Unscrew (3) main burner orifices from the manifold and
replace with the (3) L.P. orifices provided.
IMPORTANT:
Use extreme care when removing and
replacing the orifices. The orifices are made of brass,
which is easily damaged.
8.
To convert the gas valve for use with unregulated L.P.
gas, refer to the instructions included in kit envelope
(#92-1022) supplied.
9.
To convert the gas valve for use with regulated L.P. gas,
refer to the instructions included in kit envelope
(#92-0659) supplied.
10. Reverse procedure for reinstalling the gas valve/manifold
assembly to the dryer.
11A.
NON-CE DRYERS ONLY
Affix L.P. Conversion Label (ADC P/N 112011) to the dryer’s
rating plate.
Complete L.P. Conversion Confirmation Label (ADC P/N
114083) and affix this label as close as possible to the dryer’s
existing rating plate.
Affix L.P. Conversion Rating Plate Addendum (ADC P/N
114090) as close as possible to the dryer’s existing rating
plate.
11B.
CE DRYERS ONLY
Affix a new rating plate to the dryer’s existing rating plate.
12. Open all shutoff valves (closed in Step #2), reconnect
electrical power to the dryer, and test for leaks.
IMPORTANT:
Never test for leaks with an open flame!!!
Use a soapy water solution or product intended for that
purpose.
13. Verify conversion (check list)
“ITEM”
“YES”
a.
Burner orifices changed:
______
b.
Gas valve converted:
______
c.
Wiring reconnected to gas valve,
and wiring connections verified:
______
d.
Labels provided affixed to gas valve,
and area close to and/or on dryer’s
existing rating plate:
______
e.
Test for gas leaks:
______
f.
Manifold pressure tested:
______
g.
Operate the dryer through one complete
cycle to ensure proper operation.
______
IMPORTANT:
Conversion must be performed by competent
technicians in accordance with local and state codes.
Improper assembly or adjustments can cause hazardous
conditions.
14. Select from the following two options, the adjustments to
be performed:
Unregulated Gas Valve
Regulate (govern) gas externally (refer to “Supply
Pressure” in chart on
page 19
) to the correct gas pressure
for the gas being used. Close control door and operate
dryer through one complete cycle to ensure proper
operation.
FIGURE 5