87
1. Solenoid Coil
a. Coil Replacement
1) Discontinue air supply to the dryer.
2) Discontinue electrical service to the dryer.
3) For models with a sprinkler system, discontinue water supply to the dryers' sprinkler system.
4) Loosen coil plug screw and remove the plug.
5)
Carefully
remove the coil mounting screw.
IMPORTANT
:
TAKE NOTICE
... small components!!!
6) Note the sequence of the plunger components (i.e., return spring, plunger, etc.).
7) Install new coil making sure that component reinstallation (i.e., return spring, plunger, etc.) is in the
correct sequence.
8) Replace coil plug remove in
Step #4
.
9) Reestablish water supply to the dryer.
10) Reestablish electrical service to the dryer.
11) Reestablish air supply to the dryer.
Содержание AD-464
Страница 70: ...66...
Страница 88: ...84...
Страница 93: ...89 MAN4223...