112144 - 46
www.adclaundry.com
45
SECTION VIII
TROUBLESHOOTING
IMPORTANT: YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND
THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR
GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS
FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY
EQUIPMENT PER OSHA
(Occupational Safety and Health Administration)
STANDARDS.
The information provided will help isolate the most probable component(s) associated with the difficulty described.
The experienced technician realizes, however, that a loose connection or broken/shorted wire may be at fault where
electrical components are concerned...and not necessarily the suspected component itself.
Electrical parts
should always be
checked for failure before being returned to the factory.
The information provided
should not be
misconstrued as a handbook for use by an untrained person making repairs.
IMPORTANT:
When replacing blown fuses, the replacement
must be
of the exact rating as the fuse
being replaced.
WARNING: ALL
SERVICE AND TROUBLESHOOTING
SHOULD BE
PERFORMED BY A
QUALIFIED PROFESSIONAL OR SERVICE AGENCY.
WARNING:
WHILE MAKING REPAIRS, OBSERVE
ALL
SAFETY PRECAUTIONS
DISPLAYED ON THE DRYER OR SPECIFIED IN THIS MANUAL.
A. No light emitting diode (L.E.D.) display...
1. Service panel fuse blown or tripped breaker.
2. Blown control circuit fuse (3 AG 1/2-amp [Slo-Blo] fuse).
3. Failed Dual Microprocessor Controller (DMC) computer.
B. Basket (tumbler) does not start, but motor and DMC computer motor L.E.D. dot and motor
output L.E.D. indicators are on...
1. DMC computer indicator is on...
a. Failed motor contactor/relay.
b. Failed motor.
2. DMC computer indicator is off (and the L.E.D. display does not read “door”)...
a. Failed DMC computer.