![ADC AD-25V Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/adc/ad-25v/ad-25v_installation-manual_2847664050.webp)
50
American Dryer Corp.
113329 - 14
DUAL TIMER MODELS
A.
Dryer will not start...both drive motor and blower motor are not operating (indicator light is
off)...
1. Dryer control circuit fuse is blown.
2. Open at location...service main fuse or circuit breaker.
3. Failed push to start relay.
4. Failed door switch and/or circuit.
5. Failed heat timer.
6. Failed dual timer relay.
B.
Drive motor (only) is not operating...
1. Failed drive motor contactor.
2. Failed reversing timer (for Reversing Models Only).
3. Failed drive motor.
C.
Blower motor (only) is not operating...
1. Failed blower (squirrel cage fan) motor contactor (relay).
2. Failed blower (squirrel cage fan) motor.
D.
Both drive motor and blower motor are not operating (indicator light is on)...
1. Fault with L1 termination at reversing timer (for Reversing Models Only).
2. Failed drying timer.
E.
Reversing drive motor operates in one (1) direction only, stops, and restarts in same direction (for
Reversing Models Only)...
1. Failed reversing contactor (relay).
2. Failed reversing timer.
F.
Heating unit is not operating (ALL temperature selections)...
GAS MODELS ONLY
1. Fault in sail switch circuit...
a. Sail switch is out of adjustment and/or failed.
b. Sail switch is not closing or fluttering...
1) Check blower (squirrel cage fan) motor and rotation direction.
2) Restriction in location exhaust system.
2. Tripped burner hi-limit circuit.
3. Tripped lint compartment manual reset (225° F [107° C]) safety thermostat circuit.
4. Failed heat selector switch.