![ADC AD-25V Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/adc/ad-25v/ad-25v_installation-manual_2847664047.webp)
113329 - 14
47
J.
Microprocessor controller (computer) display reads “door”...
1. Fault (open circuit) in door switch circuit...
a. Failed main door switch.
b. Broken connection/wire in main door circuit.
2. Failed 24 VAC transformer.
K. Microprocessor controller (computer) will not accept any keypad entries, i.e., L.E.D. display reads
“FILL” and when keypad entries are selected, the L.E.D. display continues to read “FILL”...
1. Failed keypad label assembly.
2. Failed microprocessor controller (computer).
L.
Microprocessor controller (computer) will only accept certain keypad entries...
1. Failed keypad label assembly.
2. Failed microprocessor controller (computer).
M. Microprocessor controller (computer) locks up and the L.E.D. display reads erroneous message(s)
or only partial segments...
1. Transient power voltage (spikes)...disconnect power to dryer, wait 1 minute, and reestablish power to dryer. If
problem is still evident...
a. Failed microprocessor controller (computer).
b. Failed keypad label assembly.
N.
Dryer stops during a cycle and the L.E.D. display returns to “FILL”...
1. Fault in microprocessor heat sensor circuit...
a. Loose connection in wires between temperature sensor and microprocessor controller (computer).
2. Loose connection somewhere in main power circuit to microprocessor controller (computer).
O. No heat (for Gas Models ONLY)...ignitor sparks, burner goes on and off right away...
1. DSI ignitor/flame-probe is out of adjustment...reposition closer to the flame area.
2. Sail switch is fluttering...
a. Lint screen is dirty.
b. Restriction in exhaust ductwork.
3. Insufficient make-up air.
4. Failed ignitor/flame-probe assembly.
5. Failed DSI module.
6. Failed gas valve.
P.
Heating unit is not operating (no heat) and heat indicator dot is on...
GAS MODELS ONLY
1. Fault in sail switch circuit...
a. Sail switch is out of adjustment or has failed.
b. Sail switch damper is not closing or is fluttering...