IMPORTANT:

 Make-up air must be provided from a source

free of dry cleaning solvent fumes.  Make-up air that is
contaminated by dry cleaning solvent fumes will result in
irreparable damage to the motors and other dryer components.

NOTE:

 Component failure due to dry cleaning solvent fumes

will void the warranty.

Fresh Air Supply Requirements ______

This appliance may only be installed in a room that meets the
appropriate ventilation requirements specified in the national
installation regulations.
When the dryer is operating, it draws in room air, heats it, passes
this air through the tumbler, and exhausts it out of the building.
Therefore, the room air must be continually replenished from
the outdoors.  If the make-up air is inadequate, drying time and
drying efficiency will be adversely affected.  Ignition problems
and sail switch “fluttering” problems may result, as well as
premature motor failure from overheating.
Air supply (make-up air) must be given careful consideration
to ensure proper performance of each dryer.  An unrestricted
source of air is necessary for each dryer.  An airflow of 2,150
cfm (cubic feet per minute) (60.88 cmm [cubic meters per
minutes]) must be supplied to each dryer.  As a general rule,
an unrestricted air entrance from the outdoors (atmosphere)
of a minimum of 3 square feet (0.28 square meters) is required
for each dryer.
To compensate for the use of registers or louvers used over
the openings, the area must be increased by approximately
thirty-three percent.  Make-up air openings should not be
located in an area directly near where exhaust vents exit the
building.
It is not necessary to have a separate make-up air opening
for each dryer.  Common make-up air openings are acceptable.
However, they must be set up in such a manner that the make-
up air is distributed equally to all the dryers.  The dryer must
be installed with provisions for adequate combustion and
make-up air supply.
EXAMPLE: For a bank of six gas dryers, two openings
measuring 3 feet by 3 feet (0.91 meters by 0.91 meters) are
acceptable.

Exhaust Requirements _______________

General Exhaust Ductwork Information

Exhaust ductwork should be designed and installed by a
qualified professional.  Improperly sized ductwork will create
excessive back pressure which results in slow drying,
increased use of energy, overheating of the dryer, and
shutdown of the burner by the airflow (sail) switches, burner
hi-limits, or tumbler hi-heat thermostats.  The dryer must be
installed with a proper exhaust duct connection to the outside.
The design of the flue system shall be such that any
condensate formed when operating the appliance from cold
shall either be retained and subsequently re-evaporated or
discharged.

CAUTION: This dryer produces combustible lint and
must be exhausted to the outdoors.
Improperly sized or installed exhaust ductwork can
create a potential fire hazard.

NOTE:

 This dryer is manufactured with a back draft damper.

Allowances must be made for remote or constricting
passageways or where dryers are located at excessive
altitudes or predominantly low pressure areas.

Содержание AD-120ES

Страница 1: ...ez vous de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incendie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Ne pas entre...

Страница 2: ...___________________________________________ ____________________________________________________________________________________________________ Replacement parts can be obtained from your reseller or...

Страница 3: ...brancher Des erreurs de c blage peuvent entra ner un fonctionnement inad quat et dangereux WARNING Children should not be allowed to play on or near the dryer s Children should be supervised if near...

Страница 4: ...perate dryer according to this manual and operator s manuals included with dryer may result in conditions which can cause serious injury death and or property damage Safety Precautions _______________...

Страница 5: ...anufacturer s Use this dryer only for its intended purpose drying fabrics The Cool Down Cycle of tumble dryers should be used to reduce the temperature of the items They should not be removed from the...

Страница 6: ...1 791 cfm 50 71 cmm EXHAUST CONNECTION DIAMETER 14 35 56 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A OVEN SIZE kW Btu hr kcal hr 72 245 700 61 900 75 6 258 000 65 000 VOLTAGE AVAILABLE...

Страница 7: ...dclaundry com 7 AD 120ES Specifications __________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice...

Страница 8: ...nufacturer reserves the right to make changes in specifications at any time without notice or obligation AD 120ES Specifications __________________________________________________________ WITH OPTIONA...

Страница 9: ...OW 1 750 cfm 49 55 cmm HEAT INPUT 300 000 Btu hr 75 599 kcal hr EXHAUST CONNECTION DIAMETER 12 30 48 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION 3 4 M N P T VOLTAG...

Страница 10: ...er Corp 113386 28 ADG 120DR Specifications ________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notic...

Страница 11: ...N or in Canada the installation must conform to applicable Canadian Standards CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 L P Gas or LATEST EDITION for General Installation and Gas Plumbing T...

Страница 12: ...re the exhaust transition piece to the dryer NOTE It is recommended that this joint be taped as well as all other duct joints to prevent moisture and lint from escaping into the building Dryer Enclosu...

Страница 13: ...the area must be increased by approximately thirty three percent Make up air openings should not be located in an area directly near where exhaust vents exit the building It is not necessary to have...

Страница 14: ...RTANT Exhaust back pressure measured by a manometer at the dryer exhaust duct area must be no less than 0 and must not exceed 0 3 in WC 0 75 mb 75 Pa NOTE When the exhaust ductwork passes through a wa...

Страница 15: ...l ductwork should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint When adding ducts the duct to be added should overlap the duct to which it...

Страница 16: ...T Exhaust back pressure measured by a manometer at each dryer exhaust duct area must be no less than 0 and must not exceed 0 3 in WC 0 75 mb 75 Pa For extended ductwork runs the cross section area of...

Страница 17: ...me without notice or obligation Electrical Service Specifications 3 Wire is available 12 8 14 3 Wire is available 12 8 14 Electric Reversing ELECTRICAL SERVICE SPECIFICATIONS PER DRYER IMPORTANT NOTES...

Страница 18: ...ty and any other relevant statutory regulations It is important that gas pressure regulators meet applicable pressure requirements and that gas meters be rated for the total amount of all the applianc...

Страница 19: ...dryer must be connected to the type of heat gas indicated on the dryer data label If this information does not agree with the type of gas available do not operate the dryer Contact the reseller who so...

Страница 20: ...P T 1 B S P T for CE and AGA dryers inlet pipe connection extending out the back area of the burner box The minimum pipe size connection supply line to the dryer is 1 1 4 diameter For ease of servicin...

Страница 21: ...ns made by a qualified professional to ensure that the installation is adequate and conforms to local and state regulations or codes IMPORTANT Failure to comply with the requirements stipulated in thi...

Страница 22: ...damage to the steam coil due to the overhung weight of the steam solenoid valve The supply and return line should be insulated This will save energy and provide safety for the operator and maintenanc...

Страница 23: ...ections will void warranty If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold freezing temperatures provisions must be made to protect these water...

Страница 24: ...a coupling must be used to provide the minimum 1 2 supply feed line If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold freezing temperatures prov...

Страница 25: ...________________________ _________________________________________________________________________________________________________________________________ _____________________________________________...

Страница 26: ...kPa L P Gas 10 5 in WC 26 1 mb 2 61 kPa IMPORTANT There is no regulator provided in an L P dryer The water column pressure must be regulated at the source L P tank or an external regulator must be ad...

Страница 27: ...Once the Cool Down Cycle begins at the end of the heat cycle the L E D display will read COOL DOWN TEMP ___ ___ MINUTES REMAINING At the end of the heat cycle the dryer will shut off the heat and con...

Страница 28: ...y is handled in an expeditious manner Parts Replacement parts should be purchased from the reseller from whom the equipment was purchased If the reseller cannot be contacted or is unknown contact the...

Страница 29: ...espondence pertaining to the returned part s must be included inside the package with the failed merchandise Each part must be tagged with the following information Model number and serial number of t...

Страница 30: ...e damper to bind or stick A back draft damper that is sticking partially closed can result in slow drying and shutdown of the heat circuit safety switches or thermostats If the hi limit trips due to a...

Страница 31: ...icator dots in the microprocessor controller computer L E D display are on Refer to the illustration below Procedure for Functional Check of Replacement Components ________ Phase 7 Microprocessor Cont...

Страница 32: ...l the drum temperature has dropped below 100 F 38 C The clear stop button on the Phase 7 keypad must be pressed to clear the error condition The open burner hi limit must be reset manually prior to th...

Страница 33: ...IL SWITCH CLOSED FAULT Sail switch is closed should be open at the start of a cycle O O O SAIL SWITCH OPEN FAULT Sail switch remained open after the cycle started Should have closed BURNER HIGH LIMIT...

Страница 34: ...ADC Part No 113386 28 02 05 15...

Отзывы: