AD-120ES / ADG-120DR

Installation Manual

Extended Side Panels/Phase 7/Phase 5/Dual Timer

WARNING: For your safety the
information in this manual must be
followed to minimize the risk of fire or
explosion and to prevent property
damage, personal injury or death.

— Do not store or use gasoline or other

flammable vapors and liquids in the
vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS:

• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your

building.

• Clear the room, building or area of all

occupants.

• Immediately call your gas supplier

from a neighbor’s phone.  Follow the
gas supplier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

— Installation and service must be

performed by a qualified installer,
service agency or the gas supplier.

AVERTISSEMENT: Assurez-vous de
bien suivre les instructions données dans
cette notice pour réduire au minimum le
risque d’incendie ou d’explosion ou pour
éviter tout dommage matériel, toute
blessure ou la mort.

— Ne pas entreposer ni utiliser d’essence

ni d’autres vapeurs ou liquides
inflammables à proximité de cet
appareil ou de tout autre appareil.

— QUE FAIRE SI VOUS SENTEZ UNE

ODEUR DE GAZ:

• Ne pas tenter d’allumer d’appareils.
• Ne touchez à aucun interrupteur.  Ne

pas vous servir des téléphones se
trouvant dans le bâtiment.

• Évacuez la pièce, le bâtiment ou la

zone.

• Appelez immédiatement votre

fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.

• Si vous ne pouvez rejoindre le

fournisseur de gaz, appelez le
service des incendies.

— L’installation et l’entretien doivent être

assurés par un installateur ou un
service d’entretien qualifié ou par le
fournisseur de gaz.

ADC Part No. 113386-28

American Dryer Corporation

88 Currant Road

Fall River MA 02720-4781 USA

Telephone: +1 (508) 678-9000  /  Fax: +1 (508) 678-9447

e-mail: [email protected]

www.adclaundry.com

Содержание AD-120ES

Страница 1: ...ez vous de bien suivre les instructions donn es dans cette notice pour r duire au minimum le risque d incendie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Ne pas entre...

Страница 2: ...___________________________________________ ____________________________________________________________________________________________________ Replacement parts can be obtained from your reseller or...

Страница 3: ...brancher Des erreurs de c blage peuvent entra ner un fonctionnement inad quat et dangereux WARNING Children should not be allowed to play on or near the dryer s Children should be supervised if near...

Страница 4: ...perate dryer according to this manual and operator s manuals included with dryer may result in conditions which can cause serious injury death and or property damage Safety Precautions _______________...

Страница 5: ...anufacturer s Use this dryer only for its intended purpose drying fabrics The Cool Down Cycle of tumble dryers should be used to reduce the temperature of the items They should not be removed from the...

Страница 6: ...1 791 cfm 50 71 cmm EXHAUST CONNECTION DIAMETER 14 35 56 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A OVEN SIZE kW Btu hr kcal hr 72 245 700 61 900 75 6 258 000 65 000 VOLTAGE AVAILABLE...

Страница 7: ...dclaundry com 7 AD 120ES Specifications __________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice...

Страница 8: ...nufacturer reserves the right to make changes in specifications at any time without notice or obligation AD 120ES Specifications __________________________________________________________ WITH OPTIONA...

Страница 9: ...OW 1 750 cfm 49 55 cmm HEAT INPUT 300 000 Btu hr 75 599 kcal hr EXHAUST CONNECTION DIAMETER 12 30 48 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION 3 4 M N P T VOLTAG...

Страница 10: ...er Corp 113386 28 ADG 120DR Specifications ________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notic...

Страница 11: ...N or in Canada the installation must conform to applicable Canadian Standards CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 L P Gas or LATEST EDITION for General Installation and Gas Plumbing T...

Страница 12: ...re the exhaust transition piece to the dryer NOTE It is recommended that this joint be taped as well as all other duct joints to prevent moisture and lint from escaping into the building Dryer Enclosu...

Страница 13: ...the area must be increased by approximately thirty three percent Make up air openings should not be located in an area directly near where exhaust vents exit the building It is not necessary to have...

Страница 14: ...RTANT Exhaust back pressure measured by a manometer at the dryer exhaust duct area must be no less than 0 and must not exceed 0 3 in WC 0 75 mb 75 Pa NOTE When the exhaust ductwork passes through a wa...

Страница 15: ...l ductwork should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint When adding ducts the duct to be added should overlap the duct to which it...

Страница 16: ...T Exhaust back pressure measured by a manometer at each dryer exhaust duct area must be no less than 0 and must not exceed 0 3 in WC 0 75 mb 75 Pa For extended ductwork runs the cross section area of...

Страница 17: ...me without notice or obligation Electrical Service Specifications 3 Wire is available 12 8 14 3 Wire is available 12 8 14 Electric Reversing ELECTRICAL SERVICE SPECIFICATIONS PER DRYER IMPORTANT NOTES...

Страница 18: ...ty and any other relevant statutory regulations It is important that gas pressure regulators meet applicable pressure requirements and that gas meters be rated for the total amount of all the applianc...

Страница 19: ...dryer must be connected to the type of heat gas indicated on the dryer data label If this information does not agree with the type of gas available do not operate the dryer Contact the reseller who so...

Страница 20: ...P T 1 B S P T for CE and AGA dryers inlet pipe connection extending out the back area of the burner box The minimum pipe size connection supply line to the dryer is 1 1 4 diameter For ease of servicin...

Страница 21: ...ns made by a qualified professional to ensure that the installation is adequate and conforms to local and state regulations or codes IMPORTANT Failure to comply with the requirements stipulated in thi...

Страница 22: ...damage to the steam coil due to the overhung weight of the steam solenoid valve The supply and return line should be insulated This will save energy and provide safety for the operator and maintenanc...

Страница 23: ...ections will void warranty If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold freezing temperatures provisions must be made to protect these water...

Страница 24: ...a coupling must be used to provide the minimum 1 2 supply feed line If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold freezing temperatures prov...

Страница 25: ...________________________ _________________________________________________________________________________________________________________________________ _____________________________________________...

Страница 26: ...kPa L P Gas 10 5 in WC 26 1 mb 2 61 kPa IMPORTANT There is no regulator provided in an L P dryer The water column pressure must be regulated at the source L P tank or an external regulator must be ad...

Страница 27: ...Once the Cool Down Cycle begins at the end of the heat cycle the L E D display will read COOL DOWN TEMP ___ ___ MINUTES REMAINING At the end of the heat cycle the dryer will shut off the heat and con...

Страница 28: ...y is handled in an expeditious manner Parts Replacement parts should be purchased from the reseller from whom the equipment was purchased If the reseller cannot be contacted or is unknown contact the...

Страница 29: ...espondence pertaining to the returned part s must be included inside the package with the failed merchandise Each part must be tagged with the following information Model number and serial number of t...

Страница 30: ...e damper to bind or stick A back draft damper that is sticking partially closed can result in slow drying and shutdown of the heat circuit safety switches or thermostats If the hi limit trips due to a...

Страница 31: ...icator dots in the microprocessor controller computer L E D display are on Refer to the illustration below Procedure for Functional Check of Replacement Components ________ Phase 7 Microprocessor Cont...

Страница 32: ...l the drum temperature has dropped below 100 F 38 C The clear stop button on the Phase 7 keypad must be pressed to clear the error condition The open burner hi limit must be reset manually prior to th...

Страница 33: ...IL SWITCH CLOSED FAULT Sail switch is closed should be open at the start of a cycle O O O SAIL SWITCH OPEN FAULT Sail switch remained open after the cycle started Should have closed BURNER HIGH LIMIT...

Страница 34: ...ADC Part No 113386 28 02 05 15...

Отзывы: