150-504-100-03
Appendix A - Technical Reference
HRE-504 List 1, List 1B, and List 2
August 1, 2002
41
10
Verify that the adjusting knob has at least 11/2 turns of free movement in and out.
11
If any binding occurs, loosen the limiting nut and turn the adjustment knob until it moves freely. Then
retighten the limiting nut.
12
Rotate the adjustment knob a full turn counterclockwise from its full clockwise position. This should turn the
pressure ON.
13
Pressurize the chamber and check the entire assembly for leaks.
14
Rotate the adjustment knob back and forth and determine that it does turn the airflow OFF when fully
clockwise and back ON when backed off 1 turn counterclockwise.