150-504-100-03

 

Appendix A - Technical Reference

HRE-504 List 1, List 1B, and List 2

August 1, 2002

 39

V

ALVE

 R

EPLACEMENT

 P

ROCEDURES

All four of the metal valves shown in 

Figure 2 on page 3

 can be replaced if needed. Order the valve replacement 

kit #132-xxxx-01 listed in 

Table 5

 to obtain new valves. Use the following procedures when replacing any of the 

four valves.

Pressure Relief Valve

The pressure relief valve (PRV) is part of an all metal, nickel-plated brass assembly as shown in 

Figure 2 on 

page 3

. The valve acts as a guard against overpressurizing the enclosure and releases the internal pressure when 

it exceeds a nominal level of 15 PSI. 

The assembly consists of an adapter that tightens into a brass fitting (located on the bottom of the baseplate), and 
the PRV valve which tightens into this adapter. The adapter has two O rings to create an airtight seal. One is 
located on its outer threaded stem that connects to the brass fitting. The other is located at the base of its inner well 
where it seals the PRV to the adapter. 

To remove and replace the PRV:

1

Grip the adapter nut with a 

3

/

4

-inch (1.9 cm) wrench and the PRV with a 

1

/

2

-inch (1.3 cm) wrench. 

2

While holding the adapter nut steady, loosen and remove the PRV by turning it counterclockwise. If the 
adapter nut becomes loose, tighten it to 60 inch-pounds.

3

Verify that the O ring in the adaptor’s inner well has remained in place. If not, reseat it.

4

Thread the new PRV into the adapter. Do not crossthread.

5

Grip the adapter nut with the 

3

/

4

-inch (1.9 cm) wrench and the PRV with a 

1

/

2

-inch (1.3 cm) wrench and torque 

the latter to 120 inch-pounds. Do not overtighten. Excessive torque does not improve the seal and may 
damage the PRV.

6

Pressurize the chamber and check entire assembly for leaks.

Breather Vent Valve

The breather vent valve (BVV) is an all metal, nickel-plated brass unit shown in 

Figure 2 on page 3

. The valve 

allows air to circulate into the enclosure so it can breath and avoid the build up of excessive moisture and other 
contaminants. 

It has a hollow threaded stem that tightens into a brass fitting (located on the bottom of the baseplate). An O ring 
is located on its outer threaded stem that connects to the brass fitting. The hollow stem contains a piece of plastic 
screen to prevent insects from entering the enclosure. 

To remove and replace the BVV:

1

Grip the BVV with a 

3

/

4

-inch (1.9 cm) wrench, and turn it counterclockwise to remove.

2

Verify that the new BVV came equipped with its O ring.

3

Thread the new BVV into the brass fitting. Do not crossthread.

4

Grip the BVV with a 

3

/

4

-inch (1.9 cm) wrench and torque to 60 inch-pounds. Do not overtighten. Excessive 

torque does not improve the seal and may damage the valve.

Содержание 150-2202-01

Страница 1: ...HIGAIN REMOTE ENCLOSURE USER MANUAL HRE 504 List 1 Part Number 150 2202 01 CLEI T1MF3004 List 1B Part Number 150 2202 12 CLEI N A List 2 Part Number 150 2202 02 CLEI T1MF4004...

Страница 2: ...s Disclaimer of Liability Information contained in this document is company private to ADC DSL Systems Inc and shall not be modified used copied reproduced or disclosed in whole or in part without the...

Страница 3: ...ent of damage to the transportation company and to ADC Order replacement equipment if necessary Check the packing list to ensure complete and accurate shipment of each listed item If the shipment is s...

Страница 4: ...Inspecting the Shipment 150 504 100 03 iv August 1 2002 HRE 504 List 1 List 1B and List 2...

Страница 5: ...Surface Mounting 10 Rack Mounting 11 Grounding the Enclosure 12 Grounding a Pole Mounted Enclosure 12 Grounding a Flat Surface Mounted Enclosure 14 Installing Doubler or Repeater Units 16 Detaching t...

Страница 6: ...essure Relief Valve 39 Breather Vent Valve 39 Air Stem Valve 40 Air Pressure Cutoff Valve 40 Appendix B Specifications ____________________________________________________________ 42 Appendix C Produc...

Страница 7: ...t 1 and List 2 Enclosure Dimensions 22 10 HRE 504 Top View with Cover Removed 23 11 HRE 504 Front and Rear Views 24 12 Lightning Protection Unit 25 13 HRE 504 Interface Wiring Diagram and Cable Assign...

Страница 8: ...List of Tables 150 504 100 03 viii Augusr 1 2002 HRE 504 List 1 List 1B and List 2...

Страница 9: ...single width mechanical slots It has a single gel filled stub HRE 504 List 1 and List 1B or air filled stub HRE 504 List 2 The gel filled unit is intended for aboveground pole mounting applications th...

Страница 10: ...pressure relief valve if the air filled unit is not pressurized The assembly allows the enclosure to breathe and keeps the internal atmosphere free of harmful contaminants Figure 2 on page 3 shows the...

Страница 11: ...her vent valve Insect screen Air inlet Air outlet Adapter Breather adapter Baseplate outer surface Baseplate outer surface Baseplate outer surface Baseplate outer surface Baseplate connection Cap Valv...

Страница 12: ...it has a breather vent valve instead of a pressure relief valve The breather vent valve allows the circulation of outside air through the gel filled enclosure when it is not pressurized The enclosure...

Страница 13: ...ve covering that withstands exposure to sunlight atmospheric temperatures ground chemicals and stresses expected in standard installations The HRE 504 cable sealing O ring and V Band seal have been sa...

Страница 14: ...inlet air supply turn the air cutoff valve clockwise 1 full turn To turn on the inlet air supply turn the air cutoff valve counterclockwise 1 full turn To avoid pressure buildup the pressure relief va...

Страница 15: ...List 1 and List 2 Technical Practice Before installing the HRE 504 unpack and inspect the shipment for missing components and physical damage that may have occurred during shipping To unpack the enclo...

Страница 16: ...t surface mounting see Flat Surface Mounting on page 10 Rack mounting see Rack Mounting on page 11 A mounting template drawing is included with the bracket to help you locate the correct mounting hole...

Страница 17: ...k the location of the center mounting holes Use the two middle mounting holes for this application Remove the mounting bracket 4 Drill two 1 4 inch 0 635 cm diameter mounting holes at the locations ma...

Страница 18: ...two holes on the outside bottom of the mounting bracket Tighten the lag bolts 7 Secure the enclosure bracket to the pole by securely tightening all lag bolts 8 Reattach the enclosure base mounting bra...

Страница 19: ...case If the cable stub connects to an aerial cable form a drip loop in the cable and dress it up the wall to the splice case Rack Mounting Have the following equipment ready before you begin this pro...

Страница 20: ...nce must be 25 W or less 4 If the resistance requirement is met proceed to Step 5 If the requirement is not met follow local practices to lower the resistance to ground to comply with the requirement...

Страница 21: ...quirement in Step 8 is not met ground the main cable shield every 2 000 feet 610 m Figure 5 Grounding for Pole Mounted Unit If the main feeder cable s shield is bonded to the stub s shield the green i...

Страница 22: ...0 and 2 5 Newton meters 5 Use a 6 AWG cable to connect the main cable shield to the ground connection in the manhole 6 Using a Megger type ohmmeter measure the main cable shield resistance to manhole...

Страница 23: ...Installation HRE 504 List 1 List 1B and List 2 August 1 2002 15 Figure 6 Grounding for Flat Surface Mounted Unit HRE 504 No 6 Gauge Wire Grounding Lug No 6 Gauge Wire Bullet Bond Field Side CO Side Sp...

Страница 24: ...d in the slot connector 2 Push the unit into the card edge connector until it is entirely within the card guide The unit should snap into place indicating that it is properly seated Table 1 lists the...

Страница 25: ...eps to detach the dome from the enclosure baseplate 1 Release internal pressure 2 Unclamp the dome from the baseplate 3 Lift the dome away from the baseplate Figure 7 Detaching the Dome from the Basep...

Страница 26: ...page 5 Close the pressure cutoff valve by rotating the valve clockwise one full turn This blocks the pressure from the external source Unlock the enclosure Gently push the dome cover back and forth w...

Страница 27: ...e main cable Verify that the air cutoff valve is closed or turned fully clockwise Turn on the pressure from the external source 8 If you are pressurizing an HRE 504 List 2 from the main cable open the...

Страница 28: ...ts vertical position as shown in Figure 4 on page 8 This reduces the headroom required in manhole installations from 10 inches to less than 3 inches and the amount of valuable air space required for s...

Страница 29: ...on P1 label date code Contains the serial number date code and configuration code The date code consists of YY Last two digits of shipment year DDD Julian date The configuration code consists of Part...

Страница 30: ...age and protects the enclosure from heat and other harmful environmental effects The dome seals the inner assembly when clamped to the baseplate providing a seamless corrosion resistant easily removed...

Страница 31: ...o four doubler units The cage also has a retainer bar which serves the following purposes Writing the circuit ID of each slot on the label attached to each retainer bar Preventing the doubler or remot...

Страница 32: ...bed retainer screws at the base of the card cage one on each side lock the card cage in its normal level position which helps prevent tilting during severe vibrations The cable stubs shield is grounde...

Страница 33: ...ugh the individual gas tubes are field replaceable components replace the entire LPU when any of its protector tubes are functioning improperly See Replacement Parts on page 37 for details on replacin...

Страница 34: ...and clean it if necessary 5 Remove the pressure relief valve from the plastic bag Verify that an O ring is installed on the threaded end of the valve 6 Carefully place the threaded end of the air pre...

Страница 35: ...blue group the remaining six spares are in the orange group Order Wire Connections The external order wire pair access port is connected to its surge protector by the red and brown jumper wire The bl...

Страница 36: ...1 CO Blue White 6 Brown 5 4 1 Loop 2 In Out 2 CO Orange White 9 Slate 8 5 2 Loop 2 In Out 2 CO Orange Red 9 Blue 8 6 3 Loop 2 In Out 2 CO Orange Red 9 Orange 8 7 4 Loop 2 In Out 2 CO Orange Red 9 Gre...

Страница 37: ...corresponds to the T1 Side 2 Out pair in Figure 13 The HDSL Side 2 Out pair in Table 3 corresponds to the T1 Side 2 In pair in Figure 13 The black and white pair in the Blue group is used to access t...

Страница 38: ...mn deployment rules when mixing units from both columns in the same enclosure To comply with the requirements in TA NWT 0012101 maximum ambient temperature of 115 F with full solar load the number of...

Страница 39: ...le then make all the spans the same electrical length same 196 kHz loss This minimizes span loss and maximizes operating margin resulting in the optimum transmission performances If specific applicati...

Страница 40: ...uction When using these splicing procedures maintain cable pair integrity when splicing stub pairs into the main cable Follow local practices as required Pre splicing Procedure To pre splice the enclo...

Страница 41: ...o aid in the removal of grease 6 Remove grease by wiping the tied ends and the cable butt with a clean cloth or paper towel 7 Keep cable pairs dry Cover the exposed splice to protect it from the eleme...

Страница 42: ...ide of the cable stub with a straight splice 4 Once the cables are connected wrap the CO splice with aluminum tape or dress out the splice according to local procedures 5 Connect the field side of the...

Страница 43: ...e half its width and form the tape in place Aluminum tape provides electrical isolation from outside EMI sources For these applications dress out the splice per local practices 4 Repeat Step 3 wrappin...

Страница 44: ...nical Reference 150 504 100 03 36 August 1 2002 HRE 504 List 1 List 1B and List 2 Figure 16 Post Splicing Procedure HRE 504 CO side of the main cable CO side of the cable stub CO cable stub Field side...

Страница 45: ...LPU surge arrestors and see Table 5 on page 38 for replacement part numbers Additionally ADC recommends that the O ring be closely examined whenever the housing is opened for maintenance If the O rin...

Страница 46: ...er O Ring 1 V Band Locking Clamp 2 Desiccant two unit Bag 132 1033 01 O Ring Desiccant 1 Dome Cover O Ring 2 Desiccant two unit Bag 132 1034 01 LPU Surge Arrestor Desiccant 1 Single Slot 4 Port Protec...

Страница 47: ...kwise If the adapter nut becomes loose tighten it to 60 inch pounds 3 Verify that the O ring in the adaptor s inner well has remained in place If not reseat it 4 Thread the new PRV into the adapter Do...

Страница 48: ...ting nut The outer limiting nut tightens into the outer threads of the body housing connected to the enclosure s baseplate The stem tightens into the inner threads of the housing The stem s tip has th...

Страница 49: ...turn the adjustment knob until it moves freely Then retighten the limiting nut 12 Rotate the adjustment knob a full turn counterclockwise from its full clockwise position This should turn the pressure...

Страница 50: ...Environment Operating Temperature 40 F to 150 F 40 C to 65 C Operating Humidity 5 to 95 non condensing Altitude To 14 000 ft 4 300 m Mounting Dual or Single 239 T1 or DDS ISDN Repeater Mechanics Dime...

Страница 51: ...tion Testing System Turn Up and Testing Network Monitoring upstream or downstream Power Monitoring and Remote Surveillance Service Maintenance Agreements Systems Operation ADC Technical Assistance Cen...

Страница 52: ...dards Institute ASV Air stem Valve AWG American Wire Gauge B BVV Breather vent Valve C CLEI Common Language Equipment Identifier E ECI Equipment Catalog Item H HDU HiGain Doubler Unit I ICEA Insulated...

Страница 53: ...Appendix D Abbreviations 150 504 100 03 46 August 1 2002 HRE 504 List 1 List 1B and List 2...

Страница 54: ...l use ADC will replace defective media at no charge if it is returned to ADC during the 30 day warranty period along with proof of the date of shipment The transportation charges for shipment of retur...

Страница 55: ...ED FIRM ISO 9001 TL 9000 ADC DSL Systems Inc 14402 Franklin Avenue Tustin CA 92780 7013 Tel 714 832 9922 Fax 714 832 9924 Technical Assistance Tel 800 638 0031 Tel 714 730 3222 Fax 714 730 2400 DOCUME...

Отзывы: