6.0 Maintenance
This section describes different steps for maintenance of the light fixture.
Before you start, make sure you have read and understand
Find out the location of the light unit that needs maintenance. If the purpose is to replace an existing light unit with new one,
make sure that corresponding unit is available. Find the type information on the identification tag with details of name.
Spare parts are available, if required. For more information, see
and the Spare Parts List document, or
contact ADB SAFEGATE for assistance.
Important
Use of incorrect combination of gaskets, bolts and nuts can create severe damages to the product installation and
create multiple safety risks.
You need to know what base the light fixture will be installed in, in order to chose the correct gasket, bolts and nuts.
Failure to follow these cautions can result in equipment damage or aircraft FOD. For more information, refer to
CAUTION
When a light fixture has been removed from its base, the base must be either fitted with a cover or a spare light fixture
put in its place. It is recommended that only authorized personnel disassemble fittings with prior agreement from
ADB SAFEGATE.
6.1 Safety instructions
CAUTION
Electric Shock Hazard
Prior to the commencement of work all electrical services MUST be isolated from the supply and connected to earth.
Full details of the work involved must be given to the Authorised Person responsible for the electrical engineering
services at the airport with regard to the duration of the work and so on. .. It is recommended that prior to starting
any cutting work the nature and location of services such as cable ducts and so on. should be identified Any
installation or maintenance work should only be carried out by trained and experienced personnel.
CAUTION
High Light intensity!
Do not stare directly into the light beam at a close distance.
6.2 Safety Considerations
Read the installation section of all system component manuals before starting these steps. A thorough understanding of
system components and their requirements will promote safe and efficient installation. See FAA AC 150/5340-30, Design and
Installation Details for Airport Visual Aids, and site plans and specifications for field installation of runway and taxiway in-
pavement lights.
UM-5027, Rev. 1.0, 2020/12/10
27
Copyright
©
ADB SAFEGATE, All Rights Reserved
Содержание RELIANCE
Страница 1: ...RELIANCE Omni Light 8 inch User Manual UM 5027 Rev 1 0 2020 12 10 ...
Страница 2: ......
Страница 8: ...RELIANCE Omni Light List of Figures viii Copyright ADB SAFEGATE All Rights Reserved ...
Страница 10: ...RELIANCE Omni Light List of Tables x Copyright ADB SAFEGATE All Rights Reserved ...
Страница 22: ...RELIANCE Omni Light General Information 12 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 26: ...RELIANCE Omni Light Installation 16 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 36: ...RELIANCE Omni Light Operation 26 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 62: ...RELIANCE Omni Light Maintenance 52 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 70: ...RELIANCE Omni Light POWER TABLE 60 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 72: ...RELIANCE Omni Light CABLE LOSS 62 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 76: ......