background image

Adax AS  - Norway

When putting Digital DT into
operation or after a lengthy
power cut, the display will
flash, showing that no
temperature reduction
programme is active.
Press “F” to reset and DT
will revert to the default
settings: 22°C for normal
temperature and 15°C for
reduced temperature. The
duration of temperature
reduction is 7 hours at night
and 5 hours during the day.
Temperature reduction is
not activated.

First time use and after power cuts
of over 60 minutes

print # 62169 Uk

31012005

Select the normal
temperature setting

Choose the
desired normal
temperature
by pressing

 or  .

Set the correct day of the week

Set the correct week-
day by pressing ”F”
until ”d” (d=day) is
shown in the  display.
Press   or   until the
appropriate figure is
displayed.
Monday = 1, tues-
day = 2 etc. Store the
setting by pressing
”F”, or allow it to be
stored automatically
after approx. 30
seconds.

Start Night Time temperature reduction

At the time you wish
temperature reduction to
start, press ”7” until 15ºC
is displayed. The lamp
over ”7” will now flash
slowly to indicate that
temperature reduction is
active. The temperature
is lowered to 15ºC for the
next 7 hours. This will
now be repeated at the
same time every night.

Start daytime temperature reduction

What do flashing lights
and steady lights over
7 and 5 indicate?

Slow flashing shows that a
temperature reduction period, ”7”
or ”5” is ongoing. At the same
time the display will show the
temperature setting. A steady light
over ”7” eller ”5” shows that DT
is programmed for temperature
reduction, but that it is not
currently in an active period.

Change the temperature
reduction setting

Hold down on ”F”
and press 3 times
on  ”7” eller ”5”
depending on which
you wish to change.
When ”ºC” flashes
in the display,
release ”F”. Press

 or   to choose

your desired
temperature. You
can select different
daytime and night
time settings.

Alter the duration of temperature
reduction

Hold down on ”F”
and press twice
on ”7” or ”5”
depending on
which you wish
to alter. When ”h”
(hour) flashes
in the display,
release ”F”.
Press   or   to
choose the
number of hours
you wish
temperature
reduction to last.

Hold down on ”F” and
press once on ”7” or ”5”
to override the current
active period, or the
next period of
temperature reduction.
The lamp is lit steadily
for the period in
question. Temperature
reduction will resume
as usual from the
following period.

Annul a period of temperature
reduction

Delete a period of
temperature reduction

Press ”7”
or ”5” until
the green
lamp goes
out.

18°C

= 2°C deviation

(24 hours)

Calibration

Should the actual room temperature and the
DT’s setting not correspond, DT should be
calibrated. First, let the heater work steadily
at the same temperature setting, preferably
for at least 24 hours, keeping doors and
windows closed. This makes sure that the
DT is controlling room temperature. Sudden,
big changes in outdoor temperature will affect
calibration, making it less precise.

Press “F” until “d” is displayed.
Release ”F” for a moment - then
press it once more. ºC will be
displayed and then the setting for
normal temperature. Press   or 
until the display shows the same as
the actual measured room
temperature. Store by pressing
“F” or let the new setting be
automatically stored after approx.
30 seconds.

The heater will now work with
the temperature displayed by DT
matching the actual temperature
attained in the room.

20°C

20°C

20°C

Digital thermostat

Produced by

At the time you wish
temperature reduction to
start, press “5” until 15ºC
is displayed. The lamp
over “5” will now flash
slowly to indicate that
temperature reduction is
active. The temperature
is lowered to 15ºC for the
next 5 hours. This will now
be repeated at the same
time from Monday to
Friday, leaving Saturday
and Sunday unaffected.

Содержание Glamox Professional Heating

Страница 1: ... slipp F Trykk på eller for å velge antall timer senkingen skal vare Hold F fast nede og trykk 1 gang på 7 eller 5 for å annulere den perioden som er aktiv eller den først kommende senke periode Lampen vil lyse konstant i den aktuell perioden Fra følgende periode er senkingen igjen aktiv Annulere en senkeperiode Slette et senkeprogram Trykk 7 eller 5 til den grønne lampen slukker 18 C 2 C avvik 24...

Страница 2: ...to choose your desired temperature You can select different daytime and night time settings Alter the duration of temperature reduction Hold down on F and press twice on 7 or 5 depending on which you wish to alter When h hour flashes in the display release F Press or to choose the number of hours you wish temperature reduction to last Hold down on F and press once on 7 or 5 to override the current...

Страница 3: ...ivinen Toivottu lämpötila näkyy samanaikaisesti näytöllä Pudotuslämpötilan vaihtaminen Paina F alas ja paina 3 kertaa 7 tai 5 riippuen siitä kumman jakson lämpötilaa haluat muuttaa Kun ºC vilkkuu näytöllä vapauta F Paina tai valitaksesi pudotuslämpötilan Voit valita eri lämpötiloja päivä tai yölämpötiloiksi Pudotusjakson pituuden vaihtaminen Paina F alas ja paina 2 kertaa 7 tai 5 riippuen siitä ku...

Страница 4: ...l auf 7 oder 5 drücken je nachdem welche Änderung gewünscht wird F loslassen sobald h hour Stunde im Display aufleuchtet Auf oder drücken und die Stundenanzahl für die gewünschte Dauer der Temperatur absenkung einstellen Bei gedrücktem F einmal auf 7 oder 5 drücken um die aktive Periode oder die nächste Absenkungs periode aufzuheben Während der Aufhebung einer Absenkungsperiode leuchtet die entspr...

Отзывы: