RM Series User Manual
Front panel
Rear panel
DIP switches
MIC 1 channel has an option for +20V phantom power for condenser microphones
and paging microphones with chimes.
MIC 1 also has the option of VOX control, which attenuates the line input channels 4
and 5 by -40dB when MIC 1 signal is detected and returns them to normal when
MIC 1 signal is silent.
MIC/LINE 2 (23) and MIC/LINE 3 (22) inputs can be set to MIC (up position) or LINE (down position)
sensitivity to suit the type of input being used. Be sure to make these DIP switch settings when the
amplifier is switched off. Making any changes when the amplifier is powered up may cause loud
transient noises which can damage the speakers.
1.
USB/SD/FM/BT media player
7.
BASS EQ control
2.
MIC 1 volume control
8.
TREBLE EQ control
3.
MIC/LINE 2 volume control
9.
MASTER volume control
4.
MIC/LINE 3 volume control
10.
VU level meter
5.
LINE 4 volume control
11.
POWER on/off switch
6.
LN5/USB volume control
12.
Speaker zone selector buttons (RM240SB only)
13. Mains voltage switch
20. LINE 5 input (RCA)
14. IEC mains inlet & fuse holder
21. LINE 4 input (RCA)
15. DC power terminals
22. MIC/LINE 3 input (6.3mm jack)
16. COM speaker terminal
23. MIC/LINE 2 input (6.3mm jack)
17. 8Ω speaker terminal
24. DIP switches (see DIP switches section below)
18. 100V speaker terminal (4 zones for RM240SB)
25. MIC 1 input (balanced XLR)
19. LINE OUT connectors (RCA)
26. Antenna connection for FM tuner