background image

Replacing the Ethernet Bridge modem at the sign

MaxStream® XPress™ Wireless Ethernet Bridge Replacement Instructions

3 of 4

Replacing the Ethernet Bridge modem at the sign

Tools needed

5/32-inch hex tool (pn 68117076).

Screwdriver or other tool(s) depending on the how the Ethernet Bridge modem is mounted.

WARNING! 

Hazardous voltage. Contact with high voltage may cause death or serious injury. Always 

disconnect power to unit prior to servicing.

Disconnect all power to the sign at the power source.

NOTE: 

If you are working on a back-to-back unit, disconnect power to the slave sign at the power source.

Open the controller section door (bottom left-most section):

Using a 5/32-inch hex tool to open the section door lock, turn counterclockwise and then pull the door toward you

.

1

2

Open the door slowly to prevent damage to internal components.

5/32-inch hex tool

(pn 6811-7076)

Содержание MaxStream XPress

Страница 1: ...s are used for wireless communication between the ooh Media computer and the Excite sign The MASTER modem is connected to the ooh Media computer or to your network and sends messages to your Excite sign The modem connected to your Excite sign receives messages from the MASTER modem Contents of the XPress Ethernet Bridge box Picture Quantity Description 2 XPress Ethernet Bridge RF modem The modem l...

Страница 2: ... the power cord from the PoE adapter and unplug the power adapter from the wall Disconnect the cable coming from the MASTER Ethernet Bridge modem Connect the cables to the new PoE adapter 1 2 3 DATA IN P DATA OUT POWER Connect the following to the PoE adapter A Connect the network cable from your computer or network into the DATA IN B Connect the cable from the new Ethernet Bridge modem labeled MA...

Страница 3: ...tact with high voltage may cause death or serious injury Always disconnect power to unit prior to servicing Disconnect all power to the sign at the power source NOTE If you are working on a back to back unit disconnect power to the slave sign at the power source Open the controller section door bottom left most section Using a 5 32 inch hex tool to open the section door lock turn counterclockwise ...

Страница 4: ... Bridge modem in the same manner as the old one was mounted Connect the Ethernet cable to the sign Close the sign door tighten door locks and apply power to the sign 3 Ethernet connection Push cable through this hole A Unplug the cable from the Ethernet connection B Push the cable through the hole in the back of the controller section 4 5 6 7 Ethernet connection Push cable through this hole A Rout...

Отзывы: