P
ART
REPLACEMENT
L
IGHT
SENSOR
REPLACEMENT
AlphaXpress 8731 Sign Installation and Maintenance Manual (pn 1508610601 rev. A)
49
4.
Set the address switch on the replacement light sensor board to the setting on the board that will be
replaced.
Note:
If the light sensors are not properly addressed the photocell assembly will not operate properly.
Figure 46.
Light sensor (representative view).
5.
Use a small, flat blade screwdriver to remove the wire connector form the light sensor that is being
replaced. Then remove the four screws (circled) that hold the board to the base of the light sensor
globe.
Figure 47.
Light sensor board (representative view).
6.
Attach the replacement light sensor board and screw down the wire connector.
7.
Reattach the attachment bracket and globe to the base with the 12 screws (see Figure 45 on page 48).
Address switch
Wire connector
The arrow on this dial points to
the address of the light sensor
board, “1” in this case.
Loosen the two screws on the
end of the wire connector